Superior VRT2536WS Installation And Operation Instructions Manual Download Page 11

NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.

11

FRAMING SPECIFICATIONS

Figure 7

Hood Kit Installation 

(see ordering information on 

Page 16

)

The fi rebox canopy (hood) must not be modifi ed or replaced with a 
canopy that may be provided with the unvented decorative room 
heater.

NOTE: 

 A hood comes standard and is required for models VRT2536WS 

and VRT2542WS.  The factory-supplied hood must be installed on the 
fi rebox for safe operation for models VRT2536WS and VRT2542WS in 
all installations.

 See

 

Figure 11.

These hood kits are design to be fi tted to the face of the appliance directly 
above the fi rebox opening.  In addition to providing an aesthetically pleasing 
appearance to your appliance, the hood reduces heat effects to decora-
tive mantels and fi nish materials located directly above the fi replace and 
reduces the Mantel / Trim clearances (see 

Figure 4 

on

 Page 7

).

Please read this entire manual and understood thoroughly before proceeding 
with the installation of these kits. 

Step 1.

 Using a 5/16" nut driver or socket, remove the screen and rod 

assemblies as shown in 

Figure 10.

Step 2.

 Align the hood with the holes in the side frames as shown in 

Figure 11

.  Install three screws as shown in 

Figure 11

. Make 

sure hood is level and secure.

Step 3.

 Reinstall screen and rod assemblies

 (see

 Figure 10

).

Framing Dimensions

Opening

VRT2536WS

VRT2542WS

A

42-1/4" (1073)

48-1/4" (1226)

B

40-1/4" (1022)

40-1/4" (1124)

C

23-5/8" (600)

29-5/8" (753)

D

11-1/4" (286)

15-1/4 (387)

E

63-1/2" (1613)

69-3/4 (1772)

F

31-3/4" (807)

34-7/8 (886)

             G *

20-1/2"( 521)

20-1/2"( 521)

H

44-1/4" (1124)

49-3/8 (1254)

Table 1 - 

This Table corresponds to Figures 7, 8 and 9

Rough Framing Face
(Unfi nished Shown)

Back Wall Of Chase/Enclosure 
Including Finishing Materials If Any

Rough Framing Face
(Unfi nished Shown)

A

C

G

Parallel Installation

Figure 8

Figure 9

This Figure cor-
responds to Table 1

This Figure corresponds 
to Table 1

WARNING: Do not fi ll 
spaces around the 
fi rebox with insulation 
or other materials.

A

B

Header

Figure 10

Removing Screens and Rods:

Remove screws (see dotted 
lines).  Pull out rods from 
locating holes on side of fi rebox 
opening.

Reinstalling Screens and Rods:

Insert rods into corresponding 
locating holes on sides of fi rebox 
opening, then reinstall screws 
as shown.

A

C

D

H

F

G

E

Back Wall Of Chase/Enclosure 
Including Finishing Materials If Any

Rough Framing Face
(Unfi nished Shown)

Corner Installation

This Figure corresponds to Table 1

* Back wall of chase/enclosure including fi nishing materials, if any.

Summary of Contents for VRT2536WS

Page 1: ...IONS THIS IS A VENT FREE GAS FIRED HEATER ENCLO SURE IT USES AIR OXYGEN FROM THE ROOM IN WHICH IT IS INSTALLED PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR MUST BE PROVIDED REFER TO COMBUSTI...

Page 2: ...perating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a professional service person More frequent...

Page 3: ...EGIN NING YOUR INSTALLATION Packaging List Vent Free Gas Firebox Hood Installation and Operation Instructions GENERAL INFORMATION TheseVent Freefireboxenclosuresaredesigned toacceptallANSIZ21 11 2appr...

Page 4: ...the maximum BTU Hr the space can support with the actual amount of BTU Hr used _________ BTU Hr max the space can support _________ BTU Hr actual amount of BTU Hr used Example 61 440 BTU Hr max the s...

Page 5: ...ree firebox must be kept clear and free from these combustible materials WARNING Do not use a blower insert heat exchanger insert or other acces sory not approved for use with this appliance WARNING D...

Page 6: ...her on the underside of the mantel Clearances Ensure the minimum clearances shown in Figures 2 through 4 are maintained Left and right clearances are determined when facing the front of the firebox Fo...

Page 7: ...ltile etc ametal or wood barrier covering the entire bottom surface must be used Combustible Mantel and Trim Clearance Models VRT2536WS and VRT2542WS WITH Hood Installed Hood is required on all instal...

Page 8: ...owever and might require a different sequence Step 1 Position firebox prior to framing or into prepared framing Step 2 Field wire the main power supply to the appliance if a blower kit is to be instal...

Page 9: ...rface If a wall covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall surface It is important that this dimension be exact Step 2 Level the fireb...

Page 10: ...2542WS 130 lbs 24 Cu Ft Fireplace Dimensions Model No A B C D E F G H J K L M N P Q VRT2536WS 36 914 24 610 41 3 4 1061 37 1 4 946 23 1 2 597 20 508 3 76 7 3 8 187 15 7 8 403 7 1 2 190 12 305 1 3 8 35...

Page 11: ...frames as shown in Figure 11 Install three screws as shown in Figure 11 Make sure hood is level and secure Step 3 Reinstall screen and rod assemblies see Figure 10 Framing Dimensions Opening VRT2536W...

Page 12: ...Ground Green Wall mounted ON OFF Blower Switch or Variable Speed Control Switch Ground HOT SIDE OF RECEPTACLE An ON OFF Wall Switch is used with the FBK 100 kit field provided or sold separately order...

Page 13: ...see Figure 16 Step3 Looselytieaknotinthepowercordtotakeupslack seeFigure19 Step 4 Locate the tabs shown in Figure 20 Position the blower assembly so that the tabs located on the cabinet base are seate...

Page 14: ...se Figure 19 Figure 20 Figure 21 Loose knot in power cord to take up slack Firebox floor Locating Tabs Bend Locating Tabs Over into notches Use screw provided and secure in place as shown The notched...

Page 15: ...l Figure 23 Raised Hearth Extension Non Combustible Wall see Figure 4 Fireplace Opening From Base to Bottom of Firebox Opening floor 5 3 4 Max Base APPROVED ACCESSORIES AND COMPONENTS Decorative Volca...

Page 16: ...Blower Variable Speed w wall mounted switch Touch Up Paint Kit Repair of minor scratches and discoloration of the appliance black painted surfaces may be accomplished with the touch up paint kit PA I...

Page 17: ...can be found on the page Normally all parts should be ordered through your distributor or dealer Parts will be shipped at prevailing prices at time of order NEVERUSESUBSTITUTEMATERIALS USEOFNON APPROV...

Page 18: ...____________________________________________ _____________________________________________________ _____________________________________________________ _______________________________________________...

Page 19: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a re hazard c...

Page 20: ...make changes at any time without notice in design materials specifications prices and the discontinuance of colors styles and products Consult your local distributor for fireplace code information NO...

Reviews: