FRAMING AND FINISHING
Figure 2 shows typical framing of this fireplace. Figure 3 shows
framing for see-thru installation. All minimum clearances must be
met. Steel framing may be necessary or wood studs may be notched.
Concrete board is provided for facing around the fireplace as shown
in Figure 4.
If you are using a separate combustible mantel piece, refer to Figure 5
for proper installation height. You can install noncombustible mantels
at any height above the fireplace.
Note:
Noncombustible mantels may discolor!
INSTALLATION
Continued
Figure 2 - Framing Clearances for One Sided Application
Figure 3 - Framing Clearances for See-Thru Application
53.25"
38"
17.50"
53.25"
38"
15.25"
53.25"
38"
17.50"
53.25"
38"
15.25"
Figure 5 - Clearances for Combustible Mantels
Ref.
Mantel
Depth Ref.
Mantel
from
Top of
Opening
1
12"
A
24"
2
9"
B
21"
3
6"
C
18"
4
4"
D
16"
5
2"
E
14"
A
B C
D E
1
2
3
4
5
Wall
Supplied firebox
hood must be
used at all times.
Note
: All vertical
measurements are
from top of fireplace
hood opening to
bottom of mantel
shelf.
Noncombustible
material may project
off this surface above
the firebox hood
Figure 4 - Installing Concrete Board
Concrete
Board
8"
Combustible
Material May
Be Used
TOP VIEW
SAFE
ZONE
Perpendicular
Wall
33°
4" to Face Opening
5"