Superior UVF-36 and Installation And Operating Instructions Manual Download Page 16

NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.

16

Outside Air Gate & Duct Kit

Cat. No.

Model No.

Description

H3991

OAK-UVFRC

Outside Air Gate & Duct Kit

Outside Air Gate & Duct Kit

These kits have an air gate assembly, 4" diam-
eter duct and a termination hood.  The air gate 
allows adjustment of the amount of outside air 
delivered to the fi re for combustion. Only one  
kit, located on the right side of the fi replace, 
is required. 

(ref. Form #750,206M)

Blower Kit

The FBK-100 blower provides for a constant velocity forced air circulation feature for your ap-
pliance.  The FBK-200 assembly with variable speed wall switch provides a forced air circulation 
feature for your appliance.

Charcoal Canopy 

Cat. #

Model

Models Where Used

H1989

FC36

UVFRC-3628, UVFRC-3628-H
 (UVF-36 standard part)

H1990

FC42

 UVFRC-4228 &  UVFRC-4228-H

* Forced Air Blower Kits

Cat. 

No.

Model No.

Description

80L84

FBK-100

Blower, Standard
(single speed)

80L85

FBK-200

Blower, Variable Speed 
(w/wall-mounted switch)

94L89

FBK-100-36

Blower, Standard, 36 Pack

94L90

FBK-200-36

Blower Kit - Variable Speed 
with Wall Switch 36 Pack

(ref. Form # 750,028M)

Touch-Up Paint Kit

Repair of minor scratches and 
discoloration of the appliance 
charcoal painted surfaces may be 
accomplished with the touch-up 
paint kit.

Touch-Up Paint Kits

Cat. No.

Model No.

Description

90L74

TPK-C

Touch-Up Paint (Charcoal)

(ref. Form # 504,216M)

PA I N T

The variable speed control 
rheostat is included with 
FBK-200 models only

An ON/OFF wall switch can be used 
with the FBK-100 models (fi eld 
supplied or order P/N 85L87 Wall 
Switch Kit, shown below)

ON/OFF Wall Switch Kit

The ON/OFF wall switch kit 
may be used to control the 
blower operation, if FBK-
100 blower kit is installed. 
Install the ON/OFF wall 
switch in a convenient 
location near the fi replace.

White Wall Switch Kit

Cat. No.

Model No.

Description

85L87

FWSK

ON/OFF Wall Switch Kit

    *   The installation of these kits also require a

 

Junction Box / Electrical 

Kit,

 not included.  See ordering information below

(ref. Form #750,195M)

(ref. Form #850,021M)

APPROVED ACCESSORIES AND 
COMPONENTS

VENT-FREE GAS LOG SETS - 

MANUAL / PIEZO IGNITION, STANDING PILOT

Cat. #

Model

Description

BTU/hr Input

Models Where Used

H2126

VFGL18-MSN-4

18” Vent-Free Gas Log Set, Natural

14,000 - 25,000

UVF-36, UVFRC-3628 & UVFRC-3628-H

H2127

VFGL18-MSP-4

18” Vent-Free Gas Log Set, Propane

14,000 - 25,000

UVF-36, UVFRC-3628, UVFRC-3628-H

H2128

VFGL24-MSN-4

24” Vent-Free Gas Log Set, Natural

17,000 - 32,000

UVF-36, UVFRC-3628  & UVFRC-3628-H

H2129

VFGL24-MSP-4

24” Vent-Free Gas Log Set, Propane

17,000 - 32,000

UVF-36, UVFRC-3628  & UVFRC-3628-H

H2130

VFGL28-MSN-4

28” Vent-Free Gas Log Set, Natural

17,000 - 32,000

UVFRC-4228 & UVFRC-4228-H

H2131

VFGL28-MSP-4

28” Vent-Free Gas Log Set, Propane

17,000 - 32,000

UVFRC-4228 & UVFRC-4228-H

SERENE HEAT 

®

  VENT-FREE GAS LOG SETS - 

MANUAL / PIEZO IGNITION, STANDING PILOT

Cat. #

Model

Description

BTU/hr Input

Models Where Used

H2053

SHGL-18MN-R

18” Vent-Free Gas Log Set, Natural

25,000 - 36,000

UVF-36, UVFRC-3628 & UVFRC-3628-H

H2054

SHGL-18MP-R

18” Vent-Free Gas Log Set, Propane

27,000 - 36,000

UVF-36, UVFRC-3628 & UVFRC-3628-H

H2055

SHGL-24MN-R

24” Vent-Free Gas Log Set, Natural

26,000 - 39,000

UVF-36, UVFRC-3628 & UVFRC-3628-H

H2056

SHGL-24MP-R

24” Vent-Free Gas Log Set, Propane

31,000 - 39,000

UVF-36, UVFRC-3628 & UVFRC-3628-H

(ref. Form #903,623M)

Summary of Contents for UVF-36 and

Page 1: ...N AND OPERATING INSTRUCTIONS UVF 36 UVFRC 3628 UVFRC 3628 H UVFRC 4228 UVFRC 4228 H WARNING DO NOT ATTEMPT TO BURN SOLID WOOD FUELS OTHER GAS LOG SETS OR ANY OTHER COMBUSTIBLE MATERIALS IN THIS VENT F...

Page 2: ...ed and or closed prior to operating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a professional se...

Page 3: ...on Page 12 Firebox Finishes Page 15 Accessories components Page 15 Replacement Parts List Page 17 This installation manual will help you obtain a safe efficient dependable installation for your applia...

Page 4: ..._________ BTU Hr max the space can support _________ BTU Hr actual amount of BTU Hr used Example 61 440 BTU Hr max the space can support 66 000 BTU Hr actual amount of BTU Hr used The space in the abo...

Page 5: ...ained In no case shall the clearances be such as to interfere with combustion air and accessibility d Installations shall be of a permanent type with a permanently piped fuel supply in accordance with...

Page 6: ...ove Appliance all models Figure 3 CAUTION Do not install in the vicinity where gasolineorotherflammableliquids may be stored The Vent Free fire boxmustbekeptclearandfreefrom these combustible material...

Page 7: ...s UVFRC 3628 and UVFRC 4228 WITH Canopy Installed Canopy is optional on these models 16 9 1 2 2 3 4 5 6 10 11 12 13 14 15 Top of Firebox Opening Screen Top of Appliance Combustible Mantel and Trim Hea...

Page 8: ...ver and might require a different sequence Step 1 Position firebox prior to framing or into prepared framing Step 2 Field wire the main power supply to the appliance if a blower kit is to be installed...

Page 9: ...If a wall covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall surface It is important that this dimension be exact Step 2 Level the firebox by...

Page 10: ...0 lbs 26 Cu Ft H1956 UVFRC 4228 H 230 lbs 26 Cu Ft A canopy comes standard and is required for model UVF 36 The fac tory supplied canopy must be installed on the firebox for safe operation for model U...

Page 11: ...re 13 Install three screws as shown in Figure 13 Make sure canopy is level and secure Step 3 Reinstall screen and rod assemblies see Figure 12 Framing Dimensions Opening UVF 36 UVFRC 3628 UVFRC 3628 H...

Page 12: ...Green Wall mounted ON OFF Blower Switch or Variable Speed Control Switch Ground HOT SIDE OF RECEPTACLE An ON OFF Wall Switch is used with the FBK 100 kit field provided or sold separately order P N 8...

Page 13: ...4 Locate the tabs shown in Figure 23 Position the blower assembly so that the tabs located on the cabinet base are seated in the notches of the blower bracket Bend the tabs over to secure the blower...

Page 14: ...ake up slack Firebox floor Model UVFRC 4228 Shown Model UVFRC 4228 Locating Tabs Bend Locating Tabs Over into notches Use screw provided and secure in place as shown The notched side of cover plates g...

Page 15: ...rm SIDE VIEW Firebox Floor Combustible Wall Figure 26 Raised Hearth Extension Non Combustible Wall see Figure 4 Fireplace Opening From Base to Bottom of Firebox Opening floor 5 3 4 Max Base APPROVED A...

Page 16: ...Switch Kit shown below ON OFF Wall Switch Kit The ON OFF wall switch kit may be used to control the blower operation if FBK 100 blower kit is installed Install the ON OFF wall switch in a convenient l...

Page 17: ...of the firebox with numbered parts and a replacement parts list can be found on the Page Normally all parts should be ordered through your distributor or dealer Parts will be shipped at prevailing pri...

Page 18: ...NOTE DIAGRAMS ILLUSTRATION ARE NOT TO SCALE 18 NOTES...

Page 19: ...NOTE DIAGRAMS ILLUSTRATION ARE NOT TO SCALE 19 NOTES...

Page 20: ...est Taft Avenue Orange CA 92865 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and produ...

Reviews: