Superior UVF-36 and Installation And Operating Instructions Manual Download Page 12

NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.

12

OPTIONAL EQUIPMENT

Blower Kits

The 

FBK-100 Blower Kits

 are used when 

a wall-mounted ON/OFF blower switch is 
desired, and the 

FBK-200 Blower Kits

 are 

used when a wall-mounted variable speed 
blower control (rheostat) is desired.  A 

Junction 

Box / Electrical Kit 

 is also required to install these 

kits (purchased separately - see 

Page 15

)

.

The blower is installed beneath the fi rebox.  
Room air is drawn in through the side slots 
of the fi replace, heated as it passes across the 
fi rebox, and discharged through the upper area 
of the fi rebox opening. 

The installation instructions for installing these 
blower kits are on 

Pages 12 through 14

.  Also see 

the installation instructions provided with the 
blower kits (Form #750,028M).   For electrical 
requirements, refer to 

Figures 14, 15 & 16.

If the blower kit is to be installed at the time of 
installation or at a later date, the main power 
supply must be installed at the time of instal-
lation.  

This will require that the electrical 

connections must be made BEFORE the fi rebox 
is framed and enclosed in the fi nished walls.  

Route a 3-wire, 120 VAC, 60 Hz, 1 ph power 
supply and connect to electrical receptacle wires 
and wall switch or rheostat.

Grounded

to Appliance

Blower Motor

Motor Plug

Receptacle

120V

Appliance Junction Box

120V, 60HZ, 
1PH BLOWER 
CONTROL CIRCUIT 
WIRING

Junction 
Box

Factory Wired

Blower

Tab
Intact

Plug blower
into this 
receptacle

Ground - Green

* Wall-mounted ON/
OFF Blower Switch
or Variable Speed 
Control Switch.

Ground

HOT SIDE OF 
RECEPTACLE

*An ON/OFF Wall Switch is used with the FBK-100 kit 
(fi eld provided or sold separately - order P/N 85L87); A 
Variable Speed Control (provided) is used with the FBK-
200 kit.  The installation of these kits also require a 
Junction Box / Electrical Kit, not included. See 

Page 

15

 for ordering information.

Note: If any of the original wire as supplied must be 
replaced, it must be replaced with type AWM 105 
degree C - 14 gage wire. 

Neutral - White

120 V

AC Black

Green
Ground
Screw

NEUTRAL 
SIDE OF
RECEPTACLE

Black

Field Wired

Figure 16

Blower

* Junction Box

Bend blower mounting 
tabs up to secure 
blower in place

 

* Electrical Outlet

Tie a loose knot in power 
cord to take up slack

Top View

Figure 15

Figure 14

Note: 

If any of the original wire as supplied must be 

replaced, it must be replaced with type AWM 105 
degree C - 14 gage wire. 

* The Junction Box / Electrical Kit is not included. 
See 

Page 15

 for ordering information.

Figure 13

Canopy

Side View

       

IMPORTANT

The 

Ground Lead 

  must be connected 

to the green screw (located on the 
junction box). Failure to do this 
could result in an electrical short or 
shock injury.    

The appliance must be electrically 
grounded in accordance with local 
codes or, in the absence of local 
codes, the national electrical code, 
ANSI/NFPA 70-(latest edition). (In 
Canada, the current CSA C22-1 
Canadian Electrical Code).

       

CAUTION

Electrical connections should 
only be performed by a qualifi ed, 
licensed electrician. Main power 
must be off when connecting to 
main electrical power supply or 
performing service.

Summary of Contents for UVF-36 and

Page 1: ...N AND OPERATING INSTRUCTIONS UVF 36 UVFRC 3628 UVFRC 3628 H UVFRC 4228 UVFRC 4228 H WARNING DO NOT ATTEMPT TO BURN SOLID WOOD FUELS OTHER GAS LOG SETS OR ANY OTHER COMBUSTIBLE MATERIALS IN THIS VENT F...

Page 2: ...ed and or closed prior to operating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a professional se...

Page 3: ...on Page 12 Firebox Finishes Page 15 Accessories components Page 15 Replacement Parts List Page 17 This installation manual will help you obtain a safe efficient dependable installation for your applia...

Page 4: ..._________ BTU Hr max the space can support _________ BTU Hr actual amount of BTU Hr used Example 61 440 BTU Hr max the space can support 66 000 BTU Hr actual amount of BTU Hr used The space in the abo...

Page 5: ...ained In no case shall the clearances be such as to interfere with combustion air and accessibility d Installations shall be of a permanent type with a permanently piped fuel supply in accordance with...

Page 6: ...ove Appliance all models Figure 3 CAUTION Do not install in the vicinity where gasolineorotherflammableliquids may be stored The Vent Free fire boxmustbekeptclearandfreefrom these combustible material...

Page 7: ...s UVFRC 3628 and UVFRC 4228 WITH Canopy Installed Canopy is optional on these models 16 9 1 2 2 3 4 5 6 10 11 12 13 14 15 Top of Firebox Opening Screen Top of Appliance Combustible Mantel and Trim Hea...

Page 8: ...ver and might require a different sequence Step 1 Position firebox prior to framing or into prepared framing Step 2 Field wire the main power supply to the appliance if a blower kit is to be installed...

Page 9: ...If a wall covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall surface It is important that this dimension be exact Step 2 Level the firebox by...

Page 10: ...0 lbs 26 Cu Ft H1956 UVFRC 4228 H 230 lbs 26 Cu Ft A canopy comes standard and is required for model UVF 36 The fac tory supplied canopy must be installed on the firebox for safe operation for model U...

Page 11: ...re 13 Install three screws as shown in Figure 13 Make sure canopy is level and secure Step 3 Reinstall screen and rod assemblies see Figure 12 Framing Dimensions Opening UVF 36 UVFRC 3628 UVFRC 3628 H...

Page 12: ...Green Wall mounted ON OFF Blower Switch or Variable Speed Control Switch Ground HOT SIDE OF RECEPTACLE An ON OFF Wall Switch is used with the FBK 100 kit field provided or sold separately order P N 8...

Page 13: ...4 Locate the tabs shown in Figure 23 Position the blower assembly so that the tabs located on the cabinet base are seated in the notches of the blower bracket Bend the tabs over to secure the blower...

Page 14: ...ake up slack Firebox floor Model UVFRC 4228 Shown Model UVFRC 4228 Locating Tabs Bend Locating Tabs Over into notches Use screw provided and secure in place as shown The notched side of cover plates g...

Page 15: ...rm SIDE VIEW Firebox Floor Combustible Wall Figure 26 Raised Hearth Extension Non Combustible Wall see Figure 4 Fireplace Opening From Base to Bottom of Firebox Opening floor 5 3 4 Max Base APPROVED A...

Page 16: ...Switch Kit shown below ON OFF Wall Switch Kit The ON OFF wall switch kit may be used to control the blower operation if FBK 100 blower kit is installed Install the ON OFF wall switch in a convenient l...

Page 17: ...of the firebox with numbered parts and a replacement parts list can be found on the Page Normally all parts should be ordered through your distributor or dealer Parts will be shipped at prevailing pri...

Page 18: ...NOTE DIAGRAMS ILLUSTRATION ARE NOT TO SCALE 18 NOTES...

Page 19: ...NOTE DIAGRAMS ILLUSTRATION ARE NOT TO SCALE 19 NOTES...

Page 20: ...est Taft Avenue Orange CA 92865 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and produ...

Reviews: