Superior SSDV-35 Series Homeowner'S Care And Operation Instructions Manual Download Page 14

14

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Standard Remote Control System 

The Model RCL (Standard) Remote Control System, 
features a simplistic OFF/ON control function for the 
fi replace.  This model includes a hand-held transmitter, 
a remote receiver with wall-mount cover plate and 
all hardware required to install the unit.  The remote 
receiver can be wall or hearth mounted.

The transmitter has ON and OFF functions that are 
activated by pressing either button on the face of 
the transmitter.  When a button on the transmitter 
is pressed, a signal light illuminates briefl y to verify 
that a signal has been sent.

The Model RCL is designed to operate with all mil-
livolt ignition systems, as well as electronic ignition 
systems.  It may be installed with use for either 
natural gas or propane gas appliances.  The RCL 
offers ease of installation and allows you to execute 
on-off commands to the fi replace effortlessly with 
one simple  motion.

The Model RCL comes complete with detailed operat-
ing instructions.

Remote Control Kit, Standard

Cat. No.

Model No.

Description

H0249

RCL

Remote Control System  
(Standard)

(ref. Form # 750,127M)

Deluxe Remote Control System 

The Model RCL-T (Deluxe) Remote Control System  
has all of the features of the standard system along 
with an added easy to read LCD screen which presents 
access to many enhancements, including; battery 
power level indicator, timer, mode of operation, 
thermostatic display including room temperature in 
either metric of English units, fl ame indicator and 
clock.  Fully programmable, the Model RCL-T allows 
for virtual command over nearly all operational and 
temperature variables, using the hand held remote 
control transmitter.

The Model RCL-T (Deluxe) remote control system 
is installed in the same manner as the standard 
system, may be operated with electronic and mil-
livolt systems with either natural gas or propane gas.  
The RCL-T comes complete with detailed operating 
instructions.

Remote Control Kit, Deluxe

Cat. No.

Model No.

Description

H0251

RCL-STAT

Remote Control System 
(Deluxe)

(ref. Form # 750,129M)

Wall Thermostat

The wall thermostat kit provides temperature control 
for optimum comfort.

Wall Thermostat, Millivolt

Cat. No.

Model No.

Description

89L36

WTK

Wall Thermostat Kit, 
White

    

  

Product Reference Information

Cat. 

No.

Model

Ship. 

Wt.(lbs)

Ship.Vol.

(inches)

H3325

SSDVT-3530CNM

115 lbs

37W x 17D x 36H 

(13.1 cu.ft).

H3326

SSDVT-3530CNE

115 lbs

37W x 17D x 36H 

(13.1 cu.ft).

H3327

SSDVR-3530CNM

115 lbs

37W x 17D x 36H 

(13.1 cu.ft).

H3328

SSDVR-3530CNE

115 lbs

37W x 17D x 36H 

(13.1 cu.ft).

H3329

SSDVT-4035CNM

125 lbs

42W x 17D x 41H 

(16.9 cu.ft).

H3330

SSDVT-4035CNE

125 lbs

42W x 17D x 41H 

(16.9 cu.ft).

H3331

SSDVR-4035CNM

125 lbs

42W x 17D x 41H 

(16.9 cu.ft).

H3332 SSDVR-4035CNE

125 lbs

42W x 17D x 41H 

(16.9 cu.ft).

Variable Speed Wall Switch

Provides variable speed control if optional blower 
kit is purchased.

Variable Speed Wall Switch

Cat. No.

Model No.

Description

045571H

VSWS

Variable Speed Wall Switch

ACCESSORY COMPONENTS

Unit-Mountable Rocker Switch

This rocker switch kit can be installed directly in 
the gas valve mounting bracket (millivolt gas valve 
equipped fi replaces) to provide On/Off operation in 
lieu of a wall switch.

(ref. Form # 750,037M)

Rocker Switch Kit

Cat. No.

Model No.

Description

80L41

FRS

Rocker Switch Kit

OFF/ON Wall Switch Kit

 

The OFF/ON wall switch kit may be used to control 

the operation of the fi replace burner. Install the 
OFF/ON wall switch in a convenient location near 
the fi replace.

White Wall Switch Kit

Cat. No.

Model No.

Description

85L87

FWSK

OFF/ON Wall Switch Kit

Summary of Contents for SSDV-35 Series

Page 1: ...ONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE POUR VOTRE S CURIT Ne pas entreposer ni utiliser d essence ni d autre vapeurs ou liquides inflammables dans le voisinage de cet apparei...

Page 2: ...is manual For assistance or additional information consult a qualified installer service agency or the gas supplier SAFETY WARNIING INFORMATION WARNING Thesefireplacesareventedheat ers Do not burn woo...

Page 3: ...Manually Modulated Gas Valves millivolt models NATURAL GAS Models Input Rate BTU HR SSDV 3530CNM 23 000 high 17 500 low SSDV 4035CNM 29 000 high 21 500 low Table 1 Input BTU Manually Modulated Gas Val...

Page 4: ...may take a few hours or a few days KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS THE ODOR AND HAZE EMITTED DURING THE CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTO...

Page 5: ...neywell Millivolt Gas Valve Figure 5 O N OFF P I L OT L O H I OFF ON OFF ON Figure 3 Optional Blower OFF ON Rocker Switch SIT Millivolt Gas Valve Gas Outlet Gas Inlet Pilot Adjustment Screw Terminals...

Page 6: ...rer see Page 24 for ordering information Re Install Embers Logs and Volcanic Stone Carefully follow placement instructions on Pages 8 to 10 All logs should fit onto cor responding pins and or log stop...

Page 7: ...iance checkout and adjust ment period a potential safety hazard exists EXERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while t...

Page 8: ...per combustion could occur and result in soot and or excessive production of carbon monoxide CO a colorless odorless toxic gas INSTALL VOLCANIC STONE GLOWING EMBERS AND LOGS 1 Remove front glass enclo...

Page 9: ...nhere 1through5 andpertheinstructionsonPage8 A Notch Notch 2 C 3 Notchesonbottomoflog C fitsover2locatingbrackets Topforkonlog B fitsintonotchonlog A B A 4 D A 5 Topforkonlog D fitsintonotchonlog A Pl...

Page 10: ...1through5 andpertheinstructionson Page8 D A 4 A Bottomoflog B restsonsubfloor B Topforkonlog D fitsintonotchonlog A asshown Topforkonlog B fitsintonotchonlog A as shown 1 Place Embers and Volcanic St...

Page 11: ...ance for a few more minutes to ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your i...

Page 12: ...couple Thermopile Pilot Nozzels SIT MILLIVOLT PILOT ASSEMBLY 3 8 Min 9 mm Igniter Rod Hood Proper Pilot Flame Appearance Figure 13 Proper Pilot Flame Appearance Thermocouple Thermopile Pilot Nozzels 3...

Page 13: ...ttacheddirectlytothe appliance on a pullout panel located within the control compartment TH TP TH TP Thermopile If any of the original wire as supplied must be replaced it must be replaced with Type A...

Page 14: ...ontrol transmitter The Model RCL T Deluxe remote control system is installed in the same manner as the standard system may be operated with electronic and mil livolt systems with either natural gas or...

Page 15: ...These kits can be retrofitted to previously installed appliances ref Form 750 166M Door Frame Kits A decorative door frame kit is available for use with these appliances It is designed to attach dire...

Page 16: ...the touch up paint kit TPK C ref Form 504 216M PA I N T ref Form 750 147M 4 Piece Trim Kit Cat No ModelNo Description 96K17 TK35PB4 35 4 Piece Finish Trim Kit Polished Brass SSDV 3530 96K18 TK40PB4 40...

Page 17: ...in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair may result in a fire...

Page 18: ...un commutateur lectrique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagni...

Page 19: ...been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCT...

Page 20: ...pour faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mu...

Page 21: ...eral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualif...

Page 22: ...itch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or remote...

Page 23: ...ommon leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identify proper lead this check must be done with the valve control con nected and igniter powered NO Check t...

Page 24: ...ls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 14 Gas Valve SIT 43K07 1 88J53 1 15 Piezo Igniter 91K94 1 91K94 1 16 Pilot Assembly 69L17 1 69L18 1 17 Pilot Generator 60J79 1 60J79 1...

Page 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS DIAGRAMS 7 1 2 11 12 15 14 6 21 13 3 17 20 18 16 19 4 26 27 28 29 25 24 32 31 34 30 22 33 23 8 5 9 10...

Page 26: ...26 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES...

Page 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES...

Page 28: ...reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace...

Reviews: