Superior SSDV-35 Series Homeowner'S Care And Operation Instructions Manual Download Page 13

13

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

WARRANTY

Your gas appliance is covered by a limited twenty 
year warranty. You will fi nd a copy of the war-
ranty accompanying this manual.  Please read 
the warranty to be familiar with its coverage.

Retain this manual. File it with your other docu-
ments for future reference.

REPLACEMENT PARTS

A complete parts list is found at the end of 
this manual. Use only parts supplied from the 
manufacturer.

Normally, all parts should be ordered through 
your Lennox distributor or dealer. Parts will be 
shipped at prevailing prices at time of order.

If you encounter any problems or have any ques-
tions concerning the installation or application 
of this system, please contact your distributor, 
or Lennox directly:

LHP
1110 West Taft Avenue 
Orange, CA  92865

PRODUCT REFERENCE INFORMATION

We recommend that you record the following 
important information about your fi replace. 

 

Please contact your Lennox dealer for any 
questions or concerns.  For the number of 
your nearest Lennox dealer, please call 1-800-
9-LENNOX.

Visit us at www.Lennox.com

Your Fireplace's Model Number ________________________________________

Your Fireplace's Serial Number ________________________________________

The Date On Which Your Fireplace Was Installed ___________________________

The Type of Gas Your Fireplace Uses ____________________________________

Your Dealer's Name   ________________________________________________  

When ordering repair parts, always give the 
following information:

1.

 The model number of the appliance.

2.

 The serial number of the appliance.

3.

 The part number.

4.

 The description of the part.

5.

 The quantity required.

6.

 The installation date of the appliance.

WIRING DIAGRAMS

Wiring diagrams are provided here for refer-
ence purposes only.  This information is also 
provided on schematics attached directly to the 
appliance on a pullout panel located within the 
control compartment. 

TH

TP

TH

TP

Thermopile

If any of the original wire as supplied must 
be replaced, it must be replaced with Type 
AWM105 C - 18 gage wire.

* Optional Kits Installed - OFF/ON wall switch, 
wall thermostat or remote control receiver. 
Note: Turn the appliance-mounted OFF/ON 
burner control switch to the OFF position if 
any of these kits are installed. 

Millivolt Wiring Diagram

Schematic Representation Only

Field Wired

Factory 
Wired

*Optional   Switch

Standard OFF/ON Switch

      CAUTION  

Label all wires prior to discon-
nection when servicing con-
trols.  Wiring errors can cause 
improper and dangerous appli-
ance operation.

Figure 15

Electronic Wiring Diagram (Honeywell) Showing Blower Wiring for Optional FBK-100, FBK-200 & FBK-250 Kits

Schematic Representation Only

G

BK

120
VAC

Relay Module C/W FBK-250 only. Plug blower 
into J-Box receptacle for FBK-100 or FBK-200 
application. View A for J-Box wiring.

Optional Blower

*OFF/ON Switch 
(Integral with 
Gas Valve)

Honeywell
Electronic
Gas
Valve

120 VAC
Primary

Secondary

Optional Control Switch

Junction
Box

Junction Box

Pilot Burner
Assembly

BL

BL

Wall Mounted Blower Speed Control Switch or 
ON/OFF Switch for Blower Kit (optional)

Field Wired
Factory 
Wired

BK = BLACK   BL = BLUE
R = RED         W = WHITE
G = GREEN

BK

W

BK

BK

BL

R

GROUND

24 V

Transformer

Auxiliary View A 
J-Box Wiring when 
using unit mounted 
relay module.

BK
W

G

C

A

0

2

1

Igniter
Connector

W

G BK

R

*  Leave the OFF/ON switch, which is 
integral with the gas valve, in the ON 
position.
**

Optional Control Switches

: Wall 

Switch, Wall Thermostat or Remote 
Control Receiver.

Notes:
1. If any of the original wire as supplied 
must be replaced, use Type AWM 105°C 
- 18 gage wire ONLY.
2. 120 VAC, 60 Hz - Less than 3 Amps.
Caution: label all wires prior to 
disconnection when servicing controls. 
Wiring errors can cause improper and 
dangerous operation.

White Wire 
to Opposite
Side (neutral)

Outlet Box Green 
Ground Screw

Break off Tab

Hot side
of Outlet

Figure 16

Summary of Contents for SSDV-35 Series

Page 1: ...ONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE POUR VOTRE S CURIT Ne pas entreposer ni utiliser d essence ni d autre vapeurs ou liquides inflammables dans le voisinage de cet apparei...

Page 2: ...is manual For assistance or additional information consult a qualified installer service agency or the gas supplier SAFETY WARNIING INFORMATION WARNING Thesefireplacesareventedheat ers Do not burn woo...

Page 3: ...Manually Modulated Gas Valves millivolt models NATURAL GAS Models Input Rate BTU HR SSDV 3530CNM 23 000 high 17 500 low SSDV 4035CNM 29 000 high 21 500 low Table 1 Input BTU Manually Modulated Gas Val...

Page 4: ...may take a few hours or a few days KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS THE ODOR AND HAZE EMITTED DURING THE CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTO...

Page 5: ...neywell Millivolt Gas Valve Figure 5 O N OFF P I L OT L O H I OFF ON OFF ON Figure 3 Optional Blower OFF ON Rocker Switch SIT Millivolt Gas Valve Gas Outlet Gas Inlet Pilot Adjustment Screw Terminals...

Page 6: ...rer see Page 24 for ordering information Re Install Embers Logs and Volcanic Stone Carefully follow placement instructions on Pages 8 to 10 All logs should fit onto cor responding pins and or log stop...

Page 7: ...iance checkout and adjust ment period a potential safety hazard exists EXERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while t...

Page 8: ...per combustion could occur and result in soot and or excessive production of carbon monoxide CO a colorless odorless toxic gas INSTALL VOLCANIC STONE GLOWING EMBERS AND LOGS 1 Remove front glass enclo...

Page 9: ...nhere 1through5 andpertheinstructionsonPage8 A Notch Notch 2 C 3 Notchesonbottomoflog C fitsover2locatingbrackets Topforkonlog B fitsintonotchonlog A B A 4 D A 5 Topforkonlog D fitsintonotchonlog A Pl...

Page 10: ...1through5 andpertheinstructionson Page8 D A 4 A Bottomoflog B restsonsubfloor B Topforkonlog D fitsintonotchonlog A asshown Topforkonlog B fitsintonotchonlog A as shown 1 Place Embers and Volcanic St...

Page 11: ...ance for a few more minutes to ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your i...

Page 12: ...couple Thermopile Pilot Nozzels SIT MILLIVOLT PILOT ASSEMBLY 3 8 Min 9 mm Igniter Rod Hood Proper Pilot Flame Appearance Figure 13 Proper Pilot Flame Appearance Thermocouple Thermopile Pilot Nozzels 3...

Page 13: ...ttacheddirectlytothe appliance on a pullout panel located within the control compartment TH TP TH TP Thermopile If any of the original wire as supplied must be replaced it must be replaced with Type A...

Page 14: ...ontrol transmitter The Model RCL T Deluxe remote control system is installed in the same manner as the standard system may be operated with electronic and mil livolt systems with either natural gas or...

Page 15: ...These kits can be retrofitted to previously installed appliances ref Form 750 166M Door Frame Kits A decorative door frame kit is available for use with these appliances It is designed to attach dire...

Page 16: ...the touch up paint kit TPK C ref Form 504 216M PA I N T ref Form 750 147M 4 Piece Trim Kit Cat No ModelNo Description 96K17 TK35PB4 35 4 Piece Finish Trim Kit Polished Brass SSDV 3530 96K18 TK40PB4 40...

Page 17: ...in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair may result in a fire...

Page 18: ...un commutateur lectrique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagni...

Page 19: ...been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCT...

Page 20: ...pour faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mu...

Page 21: ...eral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualif...

Page 22: ...itch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or remote...

Page 23: ...ommon leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identify proper lead this check must be done with the valve control con nected and igniter powered NO Check t...

Page 24: ...ls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 14 Gas Valve SIT 43K07 1 88J53 1 15 Piezo Igniter 91K94 1 91K94 1 16 Pilot Assembly 69L17 1 69L18 1 17 Pilot Generator 60J79 1 60J79 1...

Page 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS DIAGRAMS 7 1 2 11 12 15 14 6 21 13 3 17 20 18 16 19 4 26 27 28 29 25 24 32 31 34 30 22 33 23 8 5 9 10...

Page 26: ...26 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES...

Page 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES...

Page 28: ...reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace...

Reviews: