Superior SLBV-35 Installation Instructions Manual Download Page 5

SUPERIOR

®

 B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS

COLd CLIMATE INSULATION

For  cold  climate  installations,  seal  all  cracks 

around  your  appliance  with  noncombustible 

material  and  wherever  cold  air  could  enter 

the room. It is especially important to insulate 

outside chase cavity between studs and under 

floor on which appliance rests, if floor is above 

ground level. Gas line holes and other openings 

should  be  caulked  or  stuffed  with  unfaced 

fiberglass  insulation. 

Check  local  codes  for 

additional requirements.

If the fireplace is being installed on a cement 

slab in cold climates, a sheet of plywood or 

other raised, insulated platform can be placed 

underneath  to  prevent  cold  transfer  to  the 

fireplace and into the room. It also may help 

to sheetrock the inside surfaces and/or tape 

for maximum air tightness. 

LOCATION

In  selecting  the  location,  the  aesthetic  and 

functional  use  of  the  appliance  are  primary 

concerns.  However,  vent  system  routing  to 

the exterior and access to the fuel supply are 

also important.  

Due  to  high  temperatures,  the  appliance 

should be located out of traffic and away from 

furniture and draperies (Figure 3). 

En  raison  des  températures  élevées, 

l’appareil  devrait  être  installé  dans  un 

endroit où il y a peu de circulation et loin 

du mobilier et des tentures (Figure 3).

The location should also be free of electrical, 

plumbing  or  other  heating/air  conditioning 

ducting.

These appliances are equipped with an inte-

gral combustion air door and actuator arm.  

Combustion air kits are optional and must be 

installed before removing the securing screw 

allowing the movement of the combustion air 

actuator arm (see 

Step 5

 on 

Page 14

).

Be  aware  that  this  is  a  heat-producing  ap-

pliance.  Objects  placed  above  the  unit  are 

exposed to elevated temperatures.

The appliance should be mounted on a fully 

supported  base  extending  the  full  width  and 

depth of the unit. The appliance may be located 

on or near conventional construction materials. 

However, if installed on combustible materials, 

such as carpeting, vinyl tile, etc., a metal or 

wood barrier covering the entire bottom surface 

must be used.
These appliances may be used for bedroom 

installations in the United States and are listed 

accordingly.  These units may not be installed 

in bedrooms in Canada.

5

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 3: Typical Locations

Note: 

When the unit is installed with one side 

flush with a wall, see 

Figure 5 on Page 7.

Typical Locations

Summary of Contents for SLBV-35

Page 1: ...PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT D Y TOUCHER NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL...

Page 2: ...on system No external electrical power is required to operate these appliances however 120V AC is recommended see Step 4 Install Field Wiring on Page 12 Use Only These Approved Vent Components These v...

Page 3: ...localcodesor intheabsenceoflocalcodes with the USA National Electrical Code ANSI NFPA 70 latest edition or in Canada the Canadian Electrical Code CSA C22 1 latest edition Provide adequate clearances a...

Page 4: ...Table 3 Requirements for the Commonwealth of Massachusetts Thesefireplacesareapprovedforinstallationin the US state of Massachusetts if the following additional requirements are met Install this appli...

Page 5: ...rom furniture and draperies Figure 3 En raison des temp ratures lev es l appareil devrait tre install dans un endroit o il y a peu de circulation et loin du mobilier et des tentures Figure 3 The locat...

Page 6: ...a chimney vent servicing a solid fuel fireplace provided the B vent cap is at least 2 ft 0 6 m away from the nearest point of the chimney opening Gas Vent Rule Gas vent caps are not permitted within 8...

Page 7: ...appliance front face blacksheetmetal Neverallowcombustiblematerialstobepositioned in front of or overlapping the appliance face see Figure 5 also see Figure 30 on Page 23 Non combustible materials su...

Page 8: ...raming Frame the appliance as illustrated in Figures 8 1 and 8 2 All framing details must allow for a minimum clearance to combustible framing members as shown in Table 6 Page 7 If the appliance is to...

Page 9: ...Figure 8 1 Framing Dimensions Model No A B C SLBV 35 in 35 1 4 35 1 4 16 mm 895 895 406 SLBV 40 in 40 1 4 40 1 4 16 mm 1022 1022 406 C is the required framing depth dimension when the finish material...

Page 10: ...VER PLATE with KNOCKOUT Right Side 16 in 406 mm Hood Left Side View 5 7 8 in 149 mm NOTE It is recommended that gas be stubbed in from LEFT side only 3 in 76 mm 9 1 2 in 241 mm GAS INLET KNOCKOUT 7 3...

Page 11: ...ions Allappliancesarefactory equippedwithaflex ible gas line connector and 1 2 inch shutoff valve See Step 6 on Page 15 Never use galvanized or plastic pipe Gas lines must be routed constructed and ma...

Page 12: ...through the knockout opening and into the unit junction box 5 Connect the black power supply wire to the lower outlet s red pigtail lead and the white power supply wire to the common terminal of the...

Page 13: ...tion Instructions TRANSFORMER 3V BROWN BROWN BLACK BATTERY BACK UP BLACK SENSOR BLACK IGNITER IGNITER MODULE 3V RED PILOT IN OUT VENT LO HI TH TP TH TP IN ORANGE THTP BLACK TP GREEN TH HIGH LIMIT SWIT...

Page 14: ...the lower control compartment opening See Figure 15 To open the outside air shutter open the bottom controlaccesspanel reachintothecontrolcom partment and pull the outside air control lever all the wa...

Page 15: ...the gas flex line Using pipe dressing materials appropriate for the gas type securely affix the shut off valve to this determined pipe length at a convenient location outside of the appliance lower co...

Page 16: ...appliances only Note Lighting Instructions are also found on the literature tag tied to the gas piping next to the gas valve To access the tag open the lower control compartment door by pulling the pa...

Page 17: ...2 Separate the glowing ember material into pieces about the size of a quarter Keep the pieces fluffed up not matted Distribute the pieces over the sur face of the burner as shown in Figures 23 and 24...

Page 18: ...le at the bottom of log 4 over the nub of log 2 as shown 4 2 SLBV Firebox Accessories Parts Cat No Model No Description H7244 SLBV 35 Log Set Assembly 88L53 FGE Bag of Glowing Embers Rockwool 80L42 FD...

Page 19: ...ent sooting make sure logs do not cover any burner openings Step 4 Align the hole at the bottom of log 5 over the Nub of log 3 as shown 3 5 Step 2 Align hole at the bottom of left front log 2 over the...

Page 20: ...ing on both sides is even and equal Control Compartment Panel Hood Glass Door Header Spacing Top Standoffs Flush Nailing Flange 1 2 Nailing Flange 5 8 Nailing Flange Glass Door Spring Latch Control Co...

Page 21: ...en tally to a more open position until the proper flame appearance is achieved If flame stays lowered blue adjust the air shutter incrementally to a more closed position until the proper flame appeara...

Page 22: ...ician inspect the fireplace and venting for these conditions and repair as needed To RESET the safety limit switch push the reset button located between the wire terminals on the back of the switch Fo...

Page 23: ...ished wall position framework to accom modate the thickness of the finished wall Figure 30 For Cold Climate Insulation see Page 5 For Clearances see Page 7 Top of Appliance 1 in 25 mm min Figure 30 Co...

Page 24: ...sa Nettoyez soigneusement la plaque murale de l interrupteur pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur la surface de la plaque de l interrupteur mural qui con...

Page 25: ...screws b Remove the pressure regulator spring poppet diaphragm and bushing c Discard all removed components d Make sure the rubber gasket in stalled on the back of the replace ment pressure regulator...

Page 26: ...version label provided in the conversion kit next to the rat ing plate on the appliance Step 13 Turn on gas supply and test for gas leaks refer to Page 16 Always test pressures with the valve regulato...

Page 27: ...Notes SUPERIOR B VENTGASFIREPLACES MODELS SLBV 35 SLBV 40 INSTALLATION INSTRUCTIONS 27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE...

Page 28: ...es at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information SUPERIOR B VENT...