background image

SLBV-40 LOG PLACEMENT INSTRUCTIONS

Figure 24

Left Rear Log

Right Rear Log

Ember Chunk

Left front Log

Right front Log

5

4

2

3

1

SLBV firebox Accessories/Parts

Cat. No.

Model No.

description

H7245

SLBV-40 Log Set Assembly

88L53

fGE

Bag of Glowing Embers (Rockwool)

80L42

fdVS

Bag of decorative Volcanic Stone

Note: 

• 

Ceramic fiber logs are FRAGILE! Handle carefully to prevent breakage.

• 

Install volcanic stone and glowing embers BEFORE installing logs. 

• 

To prevent sooting, make sure logs do not cover any burner openings.

Step 4

Align the hole at the bottom of log (5)  

over the "Nub" of log (3) as shown.

3

5

Step 2

Align hole at the bottom of left front log (2) over the left front 

brackets and the right front log over the right front brackets.

3

2

1

Step 3

4

2

Right front Log "Nub"

3

Position on the left 

rear log bracket

Step 1

Left Rear 

Bracket

Right Rear Bracket

Right front Brackets

Left front Brackets

Place Ember Chunk Here

Glowing Embers

(Do not place Glowing Embers over burner slots.)

SUPERIOR

®

  B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS

19

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Summary of Contents for SLBV-35

Page 1: ...PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT D Y TOUCHER NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL...

Page 2: ...on system No external electrical power is required to operate these appliances however 120V AC is recommended see Step 4 Install Field Wiring on Page 12 Use Only These Approved Vent Components These v...

Page 3: ...localcodesor intheabsenceoflocalcodes with the USA National Electrical Code ANSI NFPA 70 latest edition or in Canada the Canadian Electrical Code CSA C22 1 latest edition Provide adequate clearances a...

Page 4: ...Table 3 Requirements for the Commonwealth of Massachusetts Thesefireplacesareapprovedforinstallationin the US state of Massachusetts if the following additional requirements are met Install this appli...

Page 5: ...rom furniture and draperies Figure 3 En raison des temp ratures lev es l appareil devrait tre install dans un endroit o il y a peu de circulation et loin du mobilier et des tentures Figure 3 The locat...

Page 6: ...a chimney vent servicing a solid fuel fireplace provided the B vent cap is at least 2 ft 0 6 m away from the nearest point of the chimney opening Gas Vent Rule Gas vent caps are not permitted within 8...

Page 7: ...appliance front face blacksheetmetal Neverallowcombustiblematerialstobepositioned in front of or overlapping the appliance face see Figure 5 also see Figure 30 on Page 23 Non combustible materials su...

Page 8: ...raming Frame the appliance as illustrated in Figures 8 1 and 8 2 All framing details must allow for a minimum clearance to combustible framing members as shown in Table 6 Page 7 If the appliance is to...

Page 9: ...Figure 8 1 Framing Dimensions Model No A B C SLBV 35 in 35 1 4 35 1 4 16 mm 895 895 406 SLBV 40 in 40 1 4 40 1 4 16 mm 1022 1022 406 C is the required framing depth dimension when the finish material...

Page 10: ...VER PLATE with KNOCKOUT Right Side 16 in 406 mm Hood Left Side View 5 7 8 in 149 mm NOTE It is recommended that gas be stubbed in from LEFT side only 3 in 76 mm 9 1 2 in 241 mm GAS INLET KNOCKOUT 7 3...

Page 11: ...ions Allappliancesarefactory equippedwithaflex ible gas line connector and 1 2 inch shutoff valve See Step 6 on Page 15 Never use galvanized or plastic pipe Gas lines must be routed constructed and ma...

Page 12: ...through the knockout opening and into the unit junction box 5 Connect the black power supply wire to the lower outlet s red pigtail lead and the white power supply wire to the common terminal of the...

Page 13: ...tion Instructions TRANSFORMER 3V BROWN BROWN BLACK BATTERY BACK UP BLACK SENSOR BLACK IGNITER IGNITER MODULE 3V RED PILOT IN OUT VENT LO HI TH TP TH TP IN ORANGE THTP BLACK TP GREEN TH HIGH LIMIT SWIT...

Page 14: ...the lower control compartment opening See Figure 15 To open the outside air shutter open the bottom controlaccesspanel reachintothecontrolcom partment and pull the outside air control lever all the wa...

Page 15: ...the gas flex line Using pipe dressing materials appropriate for the gas type securely affix the shut off valve to this determined pipe length at a convenient location outside of the appliance lower co...

Page 16: ...appliances only Note Lighting Instructions are also found on the literature tag tied to the gas piping next to the gas valve To access the tag open the lower control compartment door by pulling the pa...

Page 17: ...2 Separate the glowing ember material into pieces about the size of a quarter Keep the pieces fluffed up not matted Distribute the pieces over the sur face of the burner as shown in Figures 23 and 24...

Page 18: ...le at the bottom of log 4 over the nub of log 2 as shown 4 2 SLBV Firebox Accessories Parts Cat No Model No Description H7244 SLBV 35 Log Set Assembly 88L53 FGE Bag of Glowing Embers Rockwool 80L42 FD...

Page 19: ...ent sooting make sure logs do not cover any burner openings Step 4 Align the hole at the bottom of log 5 over the Nub of log 3 as shown 3 5 Step 2 Align hole at the bottom of left front log 2 over the...

Page 20: ...ing on both sides is even and equal Control Compartment Panel Hood Glass Door Header Spacing Top Standoffs Flush Nailing Flange 1 2 Nailing Flange 5 8 Nailing Flange Glass Door Spring Latch Control Co...

Page 21: ...en tally to a more open position until the proper flame appearance is achieved If flame stays lowered blue adjust the air shutter incrementally to a more closed position until the proper flame appeara...

Page 22: ...ician inspect the fireplace and venting for these conditions and repair as needed To RESET the safety limit switch push the reset button located between the wire terminals on the back of the switch Fo...

Page 23: ...ished wall position framework to accom modate the thickness of the finished wall Figure 30 For Cold Climate Insulation see Page 5 For Clearances see Page 7 Top of Appliance 1 in 25 mm min Figure 30 Co...

Page 24: ...sa Nettoyez soigneusement la plaque murale de l interrupteur pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur la surface de la plaque de l interrupteur mural qui con...

Page 25: ...screws b Remove the pressure regulator spring poppet diaphragm and bushing c Discard all removed components d Make sure the rubber gasket in stalled on the back of the replace ment pressure regulator...

Page 26: ...version label provided in the conversion kit next to the rat ing plate on the appliance Step 13 Turn on gas supply and test for gas leaks refer to Page 16 Always test pressures with the valve regulato...

Page 27: ...Notes SUPERIOR B VENTGASFIREPLACES MODELS SLBV 35 SLBV 40 INSTALLATION INSTRUCTIONS 27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE...

Page 28: ...es at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information SUPERIOR B VENT...

Reviews: