This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not 

prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This 

appliance is not convertible for use with other gases.

WARNING: This appliance is for installation only in 

a solid-fuel burning masonry or UL127 factory-built 

fireplace, constructed of noncombustible material 

and connected to a working flue. (See page 6 for 

minimum flue opening.)

WARNING: This is a gas-fired appliance. It uses air 

(oxygen) from the room in which it is installed. Provi-

sions for adequate combustion and ventilation air must 

be provided. Refer to the National Fual Gas Codes, 

ANSI Z233.1/NFPA 54, Section 5.3 for Combustion 

and Ventilation.

These logs are approved by the manufacturer for installation in listed indoor and outdoor solid fuel burning 

fireplaces.

 

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result 

causing property damage, personal injury or loss of life.

 

 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance.

 

 WHAT TO DO IF YOU SMELL GAS: 

• 

 Do not try to light any appliance. 

• 

 Do not touch any electrical switch; do not use any phone in your building. 

• 

 Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. 

• 

If you cannot reach your gas supplier, call the fire department.

 

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Installation and Operation Instructions

Superior™ Vented Natural Gas Logs Decorative 

Appliance

P/N 126903-01   Rev.A   02/2014

PFS

®

US

Models

PHK18

PHK24

PHK30

P126903-01

Summary of Contents for PHK18

Page 1: ...54 Section 5 3 for Combustion and Ventilation These logs are approved by the manufacturer for installation in listed indoor and outdoor solid fuel burning fireplaces WARNING If the information in thes...

Page 2: ...ated manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other...

Page 3: ...l gas or propane LP gas but not both Gas type is indicated on the rat ingplate Fieldconversionisnot permitted WARNING Donotallowfans toblowdirectlyintothefireplace Avoidanydraftsthatalterburner flame...

Page 4: ...not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can increas...

Page 5: ...bedroom or bathroom 4 Before installing in a solid fuel burning replace chimney ue and rebox must be cleaned of soot creosote ashes and loose paint by a quali ed chimney cleaner Creosote will ignite i...

Page 6: ...with a working flue and constructed of noncombus tible material The charts in Figure 2 indicate technical information regarding the installation of your gas log set Please make sure that all of the s...

Page 7: ...Clamp Damper www fmiproducts com 115425 01F 6 Figure 3 Attaching Damper Clamp Manufactured Fireplace Masonry Fireplace Damper Damper CONNECTING TO GAS SUPPLY WARNING A quali ed ser vice person must co...

Page 8: ...6 Checking Gas Joints Gas Meter Equipment Shutoff Valve system Pressures in excess of 1 2 psig 3 5 kPa will damage appliance regulator 2 Cap off open end of gas pipe where equip ment shutoff valve wa...

Page 9: ...e feeds into replace This log set is factory set up for right side facing gas feed If your gas line is on the right side go to Installation and Gas Connection If your gas line is on the left side of r...

Page 10: ...led roughly or if hit together while being placed INSTALLATION Continued www fmiproducts com 115425 01F 9 INSTALLATION Continued ADDING PAN MATERIAL 1 Open bag of glowing embers and spread it evenly o...

Page 11: ...y call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department LIGHTING INSTRUCTIONS 1 STOP Read the safety inform...

Page 12: ...tural and un avoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This isespeciallytruewithpropane LP gas Burner is excessively noisy Note The move...

Page 13: ...heating or contracting while cooling 1 Log Set burning vapors from paint hair spray glues cleaners chemi cals new carpet etc See IMPORTANT statement above 2 Gas leak See Warning statement at top of p...

Page 14: ...original replacement part s call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 When calling have ready your name your address model and serial numbers of your appliance how appliance was malfunctioning...

Page 15: ...ducts com 115425 01F 14 PARTS MODELS PHK18 PHK24 PHK30 BCS18 BCS24 AND BCS30 Number and style of logs vary by model 1 8 23 17 10 18 11 13 24 9 3 2 4 5 6 7 22 15 16 20 12 21 19 14 PARTS MODELS PHK18 PH...

Page 16: ...n 1 8 901242 01 Damper Clamp Assembly 1 9 11209 Nut 10 24 2 10 114986 01 Log Grate 1 114986 02 Log Grate 1 114986 03 Log Grate 1 11 901481 01 Bottom Log 1 109128 02 Bottom Log 1 109128 01 Bottom Log 1...

Page 17: ...ll produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product...

Page 18: ...EP THIS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________...

Page 19: ...________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________...

Page 20: ...126903 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126903 01...