background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

8

 

 

63L10  

FTF8-12

 

63L13 FTF8-18

 

H0522 FTF8-24

 

63L14 FTF8-36

 

63L15 FTF8-48

 

63L92 FTF8-18C**

Chimney Section 

63L93 

FTF8-36C**

 

91L46  

F8-TE26

Thimble Extension 26" 

19M52  

F8-TE26-2**

 

  HO325 FM8-AT1

Adjustable Firestop/Thimble 

HO326 

FM8-AT2**

 

HO559 FM8-PK10

Adjustable Chimney Pipe Kits 

HO560  FM8-PK20**

Stabilizer 

63L25  

FTF8-S4

INSTALLATION COMPONENTS 

Firestop Spacer (Flat) (Single Pack)  63L29  

F8FS

Firestop Spacer (Flat) (Single Pack)  63L31   F8FS-2**

Firestop Spacer (Flat) (12 Pack)  

94L76 

F8FS-12 

Firestop Spacer (30°) 

  63L30  

F8FS30

Firestop Spacer (30°) 

  63L32  

F8FS30-2**

Contemporary Termination - 

 

Round 

63L42  

FTF8-CTD

Contemporary Termination - 

 

Round, Black 

H2238  

FTF8-CTDP

 

19M55 F8F6MH

 

19M56 F8F12MH

 

63L38 (0-6/12) 

F8F6

Flashing 

63L39 (6/12-12/12) 

F8F12

Storm Collar 

63L59  

FSC

Storm Collar (12 pack)  94L77  

FSC-B-12

Offset/ Return Package

30 Degree Offset/Return Elbow  

FTF8-ES30    63L22

15 Degree Offset/Return Elbow 

FTF8-OR15 

63L28

Cold Climate Kits 

63L61 

FTF8-CCK1-LD**

**Required For Canadian Installations 2" 

Clearances - As Applicable.

900284-00 

Rev. NC

07/2014

1508 Elm Hill Pike, Suite 108

Nashville, TN 37210

www.IHP.US.com

P900284-00 

Summary of Contents for MHW36CB

Page 1: ...framing dimensions at Ceilings and Roofs Figure 4 Nail permanently using at least two 2 more fasteners after chimney sections have been assembledthroughthethimble firestopspacer combination and after...

Page 2: ...ceed 30 Chimney heights above 30 must be sup ported by a Model FTF8 S4 stabilizer installed at 30 intervals Note The Model FTF8 S4 adds 3 net effective height to the total chimney system Install the M...

Page 3: ...on can take place Step 9 FTF locking bands Model FLB may be required if the chimney extends too high above theroofflashing Asageneralrule ifthechimney extendsmorethan6 abovetheroofflashing the use of...

Page 4: ...pipe exceed10 betweenelbows achimneystabilizer must be used at the midpoint see Figure 17 The stabilizer support straps must be attached under tension in shear to structural framing members above Whe...

Page 5: ...38 7 3 4 1 0 0 1 9 1 11 78 465 1 2 38 9 1 2 0 0 0 0 10 1 11 82 469 3 4 39 1 3 4 0 1 0 1 9 1 11 93 475 3 4 39 7 3 4 1 0 0 0 10 1 12 08 481 3 4 40 1 3 4 0 1 0 0 10 1 12 24 486 40 6 1 0 1 1 9 1 12 34 He...

Page 6: ...0 0 0 72 1 47 29 59 0 1 0 1 0 0 74 1 51 31 63 0 2 1 0 0 0 80 1 60 32 64 0 0 1 1 0 0 82 1 64 33 66 2 1 1 0 0 0 85 1 70 35 69 0 1 0 0 1 0 90 1 77 36 72 2 0 2 0 0 0 93 1 83 38 75 0 0 0 2 0 0 97 1 91 40...

Page 7: ...stance where chimney is to pass through the first ceiling dimension A To find this point on your ceiling first determine the center point for a vertical chimney following the instructions for vertical...

Page 8: ...8FS 2 Firestop Spacer Flat 12 Pack 94L76 F8FS 12 Firestop Spacer 30 63L30 F8FS30 Firestop Spacer 30 63L32 F8FS30 2 Contemporary Termination Round 63L42 FTF8 CTD Contemporary Termination Round Black H2...

Reviews: