background image

9

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

WIRING DIAGRAMS

Wiring diagrams are provided here for reference purposes only.  This information is also provided on schematics attached directly to the appliance
on a pullout panel located within the control compartment.

CAUTION:  LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.  WIRING ERRORS CAN CAUSE IMPROPER AND
DANGEROUS APPLIANCE OPERATION.

WARRANTY

Your gas appliance is covered by a limited
twenty year warranty. You will find a copy of
the warranty accompanying this manual.
Please read the warranty to be familiar with
its coverage.

Retain this manual. File it with your other docu-
ments for future reference.

REPLACEMENT PARTS

A complete parts list is found at the end of this
manual. Use only parts supplied from the
manufacturer.

Normally, all parts should be ordered through
your Lennox distributor or dealer. Parts will be
shipped at prevailing prices at time of order.

When ordering repair parts, always give the
following information:

PRODUCT REFERENCE INFORMATION

We recommend that you record the following important information about your fireplace.  Please
contact your Lennox dealer for any questions or concerns.  For the number of your nearest Lennox
dealer, please call 800-731-8101

Your Fireplace's Model Number _______________________________________

Your Fireplace's Serial Number ________________________________________

The Date On Which Your Fireplace Was Installed __________________________

The Type of Gas Your Fireplace Uses ___________________________________

Your Dealer's Name _________________________________________________

If you encounter any problems or have any
questions concerning the installation or appli-
cation of this system, please contact your dis-
tributor, or Lennox directly:

LHP
1110 West Taft Avenue
Orange, CA  92865

1.

 The model number of the appliance.

2.

 The serial number of the appliance.

3.

 The part number.

4.

 The description of the part.

5.

 The quantity required.

6.

 The installation date of the appliance.

SIT And Honeywell Millivolt Wiring Diagram

If any of the original wire as supplied must be replaced,
it must be replaced with

 

Type AWM105

°

C – 18 GA. wire.

Thermopile

TH

TP

TH

TP

*TWIST WIRES “A” AND “B” TOGETHER TO OPERATE UNIT

SOLELY BY MANIPULATING THE GAS VALVE CONTROL KNOB;

OR CONNECT WIRES TO  OPTIONAL ON/OFF SWITCH OR WALL

SWITCH OR THERMOSTAT TO OPERATE UNIT.

*OPTIONAL

 ON/OFF SWITCH,

 WALL SWITCH, THERMOSTAT

OR REMOTE CONTROL RECEIVER

A

B

1. If any of the original wire as supplied must be replaced,

1.  

it must be replaced with

 

Type AWM 105

°

C – 18 GA. wire.

2. 120V, 60Hz – Less than 3 amps.

BK

Junction Box

Transf.

120 V.

24 V

Factory Wired

Field Wired

BL

Electronic Wiring Diagram (Honeywell)

Showing the Blower Wiring for the Optional

FBK-100 and FBK-200 Kits

R

W

BL

OPT

BLOWER

G

W

*OPTIONAL

ACCESSORY

SWITCH

120

 VAC.

BK

W

Gas Valve

B

R

IGNITER

PILOT

ASSEMBLY

Break Off

Tab

BK

G

*Blower speed control switch is provided in FBK200 blower kit.

Outlet Box

Green Ground

Screw

Hot side of Outlet

Schematic Representation Only

**ON/OFF Switch (Integral

with Gas Valve)

**Leave the ON/OFF switch, which is integral

with the gas valve, in the ON position.

OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH

 OR OPTIONAL WALL SWITCH

OR OPTIONAL THERMOSTAT

OR OPTIONAL REMOTE RECEIVER

Red

pigtail

Black

pigtail

White Wire
to Opposite

Side

G

1. If any of the original wire as supplied must be replaced,

1.  

it must be replaced with

 

Type AWM 105

°

C – 18 GA. wire.

2. 120V, 60Hz – Less than 3 amps.

BK

Transf.

120 V.

24 V

Factory Wired

Field Wired

BL

Electronic Wiring Diagram (Honeywell)

Showing the Blower Wiring for the Optional

FBK-250 Kits

R

WH

BL

OPT

BLOWER

G

W

120

 VAC.

BK

W

Gas Valve

B

R

IGNITER

PILOT

ASSEMBLY

BK

G

Outlet Box Green

Ground Screw

Hot side of Outlet

Schematic Representation Only

*ON/OFF Switch (Integral

with Gas Valve)

White Wire

To Opposite

Side

Optional FBK-250

Module

*Leave the ON/OFF switch, which is integral

with the gas valve, in the ON position.

G

OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH

 OR OPTIONAL WALL SWITCH

OR OPTIONAL THERMOSTAT

OR OPTIONAL REMOTE RECEIVER

Summary of Contents for D-500CEN

Page 1: ...ou la zone Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service dos incendies L...

Page 2: ...ed to operate these units These appliances comply with National Safety Standards and are tested and listed by Omni Test Laboratories Report No 116 F 13 4 to ANSI Z21 88 2002 in Canada CSA 2 33 2002 an...

Page 3: ...trolvalveshowninFigure3 SIT or Figure 4 Honeywell on page 4 Appliances with electronic systems will be fitted with the elec tronic valve shown in Figure 2 on page 4 Familiarize yourself with the gas c...

Page 4: ...ep the appliance area clear and free from combustible materials gasoline and other flammable liquids 6 Remember Millivolt appliances have a con tinuous burning pilot flame Exercise caution when using...

Page 5: ...DR 800 on page 7 andverifytheflamepatternandheightdisplayed bytheapplianceconformstothepicture Flames must not impinge on the logs Refer to Figure 10 SIT Millivolt Figure 11 Honeywell Millivolt or Fig...

Page 6: ...opening on the main burner tube should be adjusted Normally the more offsets in the vent system the greater the need for the air shutter to be opened further WARNING NEVEROPERATETHEAPPLIANCE WITHOUTT...

Page 7: ...DR 500 8 D DT DR 600 or 9 D DT DR 800 For more detailed placement instructions refer to the LOG PLACEMENT GUIDE accompanying this document Proper twig placement is critical to prevent sooting Twigs sh...

Page 8: ...y pleasing appearance For best re sults spread in a non uniform manner while ensuringcompletecoverageoftheblacksheet metal surface Note Do Not place decorative volcanic stone on top of the gas burner...

Page 9: ...on of the part 5 The quantity required 6 The installation date of the appliance SIT And Honeywell Millivolt Wiring Diagram If any of the original wire as supplied must be replaced it must be replaced...

Page 10: ...display including room temperature in either metric or English units flame indicator and clock Fully programmable the Model RCL T allows for command over nearly all operational and temperature variab...

Page 11: ...0 8 R 5 K L B 1 0 L 0 8 T 5 K L B 0 0 6 R D T D D 4 0 L 0 8 R 6 K L B 2 0 L 0 8 T 6 K L B 0 0 8 R D T D D 5 0 L 0 8 R 8 K L B 2 2 L 9 9 T 8 K L B s t i K l e n a P e c a F n a e l C o N l e d o M o N...

Page 12: ...in gas control knob slightly and turn counterclockwise to PILOT 8 Push in control knob all the way and hold in Immediately light the pilot by triggering the spark ignitor pushing the button until pil...

Page 13: ...que Ne vous servez d aucun t l phone dans votre difice Appelez imm diatement votre compagnie de gaz en utilisant le t l phone du voisin S il vous est impossible de contacter votre compagnie de gaz app...

Page 14: ...use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has...

Page 15: ...inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mural la pos...

Page 16: ...lot flame for maximum flame impinge ment on thermocouple Figure 10 on page 8 SIT Figure 11 on page 8 Honeywell Check burner orifice for stoppage and remove Checkthermopilewithmillivoltmeter Takereadin...

Page 17: ...NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burner Cable Connected Measure Voltage At Valve HSI Element Output 24V Nominal See Insert...

Page 18: ...z e i P 1 0 9 8 M 4 2 1 1 0 9 8 M 4 2 1 7 3 d l e i h S t o l i P 6 0 7 2 9 B L 1 6 0 7 2 9 B L 1 o N N O I T P I R C S E D 0 0 5 R D T D D 0 0 6 R D T D D 0 0 8 R D T D D o N t r a P y t Q o N t r a...

Page 19: ...9 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS 4 2 1 13 2 5 41 40 21 14 12 6 43 23 22 24 42 3 26 25 30 31 32 33 34 35 15 D DT DR 500 16 36 11 27 37 20 10 8 D DT DR 600 D DR DR 800 9 17 7...

Page 20: ...25 032M REV H 11 2004 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consul...

Reviews: