Series TA/TX/TXR
Page 29
Jan 07, 2015
Outdoor Installation
O
UTDOOR
I
NSTALLATION
(TXR
M
ODELS
O
NLY
)
When a heater is to be mounted outdoors it must be installed in such a way that wind will have minimum
effect on its movement. This consideration is intended to eliminate undue stress on the gas flex connector.
In all cases a fresh air hood must be used in conjunction with a vent terminal of the approved type, and all
connections must be sealed with a high temperature sealant that can withstand 400°F.
Figure 28: Outdoor Installation
Note: that this heater is a sealed construction. If any services or repair is conducted in the future,
gasket materials should be inspected and replaced if found to be deteriorated.
Outdoor Installation
Vent Terminal
P/N CT011
Seal Joints
Fresh Air
Inlet Hood
P/N CS005
Seal Joints