superior fires Belrose Radiant Edwardian F500395 Installation & User'S Instructions Download Page 2

• 

This appliance is an Inset Decorative Fuel Effect appliance which provides radiant warmth utilising the latest type burner technology.

• 

The fire is designed to suit various types of fireplaces and natural draught flues as detailed in this manual.

• 

The appliance must be installed by a competent person in accordance with Gas Safety (Installation and Use) Regulations 1998. It is

strongly recommended that a GAS SAFE registered engineer be used for this purpose.

• 

Read all these instructions before commencing installation.

• 

This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space.

• 

The appliance is designed for installation on to a non-combustible hearth of at least 300mm depth.

• 

This appliance is factory set for operation on the gas type, and at the pressure stated on the appliance data plate.

• 

In the event of gas leakage from the appliance, the gas supply must be turned off at the nearest isolating valve.

• 

The appliance must be installed in accordance with the following:

• 

Failure to comply with the above could lead to prosecution and deem the manufacturer’s warranty invalid.

• 

The appliance is designed to fit various types of situations as described in sections 3.0 and 4.0.

• 

It should be noted that heaters create warm air currents.  These currents move heat to wall surfaces next to the heater. Installing the

heater next to vinyl or cloth wall coverings or operating the heater where impurities in the air (such as tobacco smoke, candle smoke

etc.) exist, may cause the walls to become discoloured.

• WARNING: 

The manufacturer of this appliance considers all surfaces as working surfaces with the exception of the control knob

and ash pan door. Where young children, pets, the elderly or infirm are concerned, a suitable fireguard should be used.

• Consult ALL instructions before installation and use of this appliance. 

• This appliance is free from any asbestos material. 

• Refractories and fuel bed are constructed from ceramic fibre.

• Slide control models : These appliances feature a battery-operated control system, and under normal usage will need a new battery

approximately every twelve months.

Burner/spark generator requirements - 1 x ‘PP3’ type (9 volt)

Refer to the appropriate section of these instructions for details of how to change the battery.
• Remote control models : This appliance features a battery-operated remote control system, and under normal usage will need
new batteries approximately every twelve months.
Remote control Handset requirements - 1 x ‘PP3’ type (9 volt)
Receiver/motor unit  requirements - 4 x ‘AA’ type (1.5 volt) 
Refer to the appropriate section of these instructions for details of how to change the batteries.

I N S T A L L A T I O N   I N S T R U C T I O N S

2

GB IE

Manufacturers' Instructions.

The Building Regulations issued by the Department for Communities and Local Government, the Building Standards (Scotland)   

(Consolidation) Regulations issued by the Scottish Development Department.

Relevant British Standards insofar as the relevant areas are not covered by these instructions.

For Republic of Ireland, reference should be made to the current edition of IS813 (the relevant standards governing installation).

1.0 IMPORTANT NOTES

© 

2011 Focal Point Fires plc.

Section

1.0
2.0
3.0
4.0
4.1
5.0
6.0
7.0
7.1
8.0
9.0

10.0
11.0
11.1
11.2
11.3
11.4
12.0

Contents

Important Notes
Appliance Data
Installation Requirements
Site Requirements
Debris Collection Space
Ventilation
Pre Fabricated Flue Boxes
Unpacking the Appliance
Component Checklist
Preparing the Appliance 
Preparing the Opening
Gas Supply Routing
Fitting the Firebox
Installation by Cable Fixing Kit
Gas Connection
Fuel Bed Layout
Fitting the Firefront / Frame
Testing and Commissioning

Page No.

2
3
3
3
4
5
5
5
5
6
7
7
7
8
8
8
8
8

Section

12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
12.9
13.0
13.1
13.2
13.3
13.4
13.5
13.6
13.7
14.0

Contents

Operating the Fire (Manual control)
Operating the Fire (Slide control)
Operating the Fire (Remote control)
Spark Gap
Operating Pressure (Manual models)
Operating pressure (Slide & Remote models)
Flue Spillage Monitoring System
Testing for Spillage
Briefing the customer
Servicing
Cleaning the Ceramics
Removing the Burner
Servicing the Burner
Pilot Assembly
Removing the Firebox
Replacing the Batteries 

(Slide control versions)

Replacing the Batteries 

(Remote control versions)

Troubleshooting Guide

Page No.

9
9
9

10
10
10
10
10
11
11
11
12
12
12
12
12
12
13

Summary of Contents for Belrose Radiant Edwardian F500395

Page 1: ... CHROME NG F500394 BELROSE RADIANT EDWARDIAN BLACK NG F500395 BELROSE RADIANT EDWARDIAN CHROME NG F500396 BELROSE RADIANT SOHO CHROME NG F500397 BELROSE RADIANT VICTORIAN BLACK NG F500398 BELROSE RADIANT VICTORIAN CHROME NG F500399 CASONA RADIANT COAL NG F500400 CASONA RADIANT PEBBLE REMOTE NG F500401 WALTHER CONVECTOR ELYSEE BRASS NG F500402 WALTHER CONVECTOR GROVE BRASS NG F500403 WALTHER CONVEC...

Page 2: ...battery approximately every twelve months Burner spark generator requirements 1 x PP3 type 9 volt Refer to the appropriate section of these instructions for details of how to change the battery Remote control models This appliance features a battery operated remote control system and under normal usage will need new batteries approximately every twelve months Remote control Handset requirements 1 ...

Page 3: ...any type of gas fire In some instances of this flue construction temperature cracking of the surface plaster may occur through no fault of the appliance An air gap or some form of insulation material should be installed to prevent normal flue temperatures from damaging wall surfaces Pre cast flues must be checked for mortar fangs and correct installation of joints flue sections in loft space and t...

Page 4: ...g providing the forward projection does not exceed 100mm Any com bustible side walls must be at least 500mm to the side of the radiant heat source As with all heating appliances any decorations soft furnishings and wall coverings i e flock blown vinyl and embossed paper positioned too close to the appliance may discolour or scorch Radiant models have a mounting depth of 180mm In accordance with BS...

Page 5: ...lled to allow plugs and screws to secure installation It is important that the sealing requirements of the appliance are met at all times and that the flue box is well sealed to any back or infill panel Note The DEPTH dimension is inclusive of any back or infill panel Stand the carton the right way up cut the strapping bands and remove the top endcap Read all the instructions before continuing to ...

Page 6: ...ews provided figure 4 The screws should locate into the pre punched holes in the sides of the firebox SUPPLY PIPE ENTRY All models Knockout holes are provided in the rear and sides of the firebox for use where concealed pipework is required Where necessary knock out the appropriate hole with a sharp tap from a hammer and fit the rubber grommet supplied A small incision can now be made in the rubbe...

Page 7: ...g When the opening is ready for installation of the fire the gas supply may be routed as per the examples shown in figure 9 IMPORTANT Wherever a concealed connection is made a rubber grommet must be used to seal the firebox The gas pipe must be suitably protected where it passes through fireplace openings Any sleeving should be sealed to the pipe at its ends This appliance is fitted with an inlet ...

Page 8: ... the inlet restrictor elbow from the inlet pipe Connect the previously installed gas supply to inlet restrictor elbow Place the burner unit into the firebox making sure that the rear lugs locate properly on to the ledge in the firebox Fit the two securing screws through the burner legs to secure the assembly Re fit the restrictor elbow to the inlet pipe of the appliance Please see the relevant sec...

Page 9: ...the control knob to an inter mediate position To turn the fire OFF move the slide control knob upwards fully to the position marked O The pilot is visible through the left hand side of the front ceramic strip When cold the coals or pebbles may be rotated for good viewing Turn the main burner con trol shown on left hand side of control valve knob fully anti clockwise Turn ignition knob shown on rig...

Page 10: ...f necessary reset by the gas supplier Upon satisfactory checking of the burner pressure turn the fire off disconnect the pressure gauge and refit the test point screw Light the fire and check for gas soundness In the event that the burner pressure is not in accordance with the figures stated in the data sec tion of these instructions the appliance must not be commissioned and the manufacturer shou...

Page 11: ...ly clean in the open air Be careful not to create dust from the coals Where necessary replace damaged components with genuine spares Seal scrap ceramic components in plastic bags and dispose at proper refuse sites as directed Re fit the ceramics by referring to the relevant section of these instructions 12 8 TESTING FOR SPILLAGE CONTINUED 11 2011 Focal Point Fires plc GB IE Match Crimp Tube Figure...

Page 12: ...t using two spanners to make cleaning easier Do not damage or try to remove the pilot injector The unit is factory set and the only check necessary is to ensure the spark gap is correct See specifications for gap setting Remove the burner unit as described previously Protect the hearth from potential damage Unroll the coiled tensioner cables from the rear of the firebox Remove the securing nip ple...

Page 13: ...Excessive flue pull Fire is too close the an air vent Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit there could be a problem with contamination of the gas supply drafts ventilation or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BENDTHETHERMOCOUPLETO MAKETHE P...

Page 14: ...f abnormal flue conditions occur It is NOT a sub stitute for an independently mounted Carbon Monoxide detector This fire is supplied with a particular style of firefront Use of the firefront will ensure an adequate airflow under the firebed for the cor rect functioning of this appliance Use ONLY the firefront supplied with the appliance Use of any other firefront could be dangerous Should any home...

Page 15: ...the control knob to an inter mediate position To turn the fire OFF move the slide control knob upwards upwards fully to the position marked O The pilot is visible through the left hand side of the front ceramic strip When cold the coals or pebbles may be rotated for good viewing Turn the main burner con trol shown on left hand side of control valve knob fully anti clockwise Turn ignition knob show...

Page 16: ... front coal strip should fit in front of the burner rail Again do not place on top of the burner rails When the front coal is in posi tion bend up the three metal tabs at the front of the tray to retain as shown in figure 8 3 Coals All of the coals are the same Take five coals and place them as shown in figure 9 Care should be taken to ensure that the coals bridge the gap between the front coal an...

Page 17: ...effect matrix used for pebble effect versions are of the same design as coal effect versions but have a different surface finish Position them as shown in figure 13 2 Open the bag of 16 ceramic pebbles All of these pebbles are the same size Take five pebbles and place them as shown in figure 14 Care should be taken to ensure that the pebbles bridge the gap between the front strip and the four supp...

Page 18: ... Refer back to section 6 0 Fuel bed layout coal effect option and fol low steps 1 and 2 The fuel effect matrix used for log effect versions is the same design as coal effect versions but has a different surface finish The front log strip is of a different design and must be handled with care Position them as shown in figure 18 2 Open the bag of 9 moulded ceramic logs All of the logs except two are...

Page 19: ... foreign matter is found on the fire it may indicate a need for servicing Do not use the fire until the source of the debris has been found and rectified Air vents where fitted should be checked periodically to ensure they are free from obstruction Before carrying out any of the following operations ensure that the fire is OFF and completely cold FIREFRONT Any dust accumulating in the firefront ma...

Page 20: ...30011 Injector stereo 76 manual control models F730091 Injector stereo 81 Remote control models F730046 Injector stereo 82 slide control models F730077 Burner assembly complete manual control TRAYEXCELC Burner assembly complete slide control TRAY087 Burner assembly complete remote control TRAY017 10 0 LIST OF REPLACEMENT PARTS GB IE 11 0 INSTALLATION DETAILS Name contact details of installer Suppl...

Reviews: