MODELS COVERED BY THESE INSTRUCTIONS

FULL DEPTH RADIANT/CONVECTOR INSET GAS FIRE

Please note : Except where otherwise stated, all rights,
including copyright in the text, images and layout of this
booklet is owned by Focal Point Fires plc.  You are not per-
mitted to copy or adapt any of the content without the
prior written permission of Focal Point Fires plc. 

1

Revision A - 10/11

© 

2011 Focal Point Fires plc.

GB IE

BS7977-1 : 2009

BS EN 509 : 2000

KM579168

WHATLEY RADIANT ELEGANCE BRASS NG

F500391

WHATLEY RADIANT GROVE BRASS NG

F500392

WHATLEY RADIANT GROVE BLACK FRAME NG

F500393

WHATLEY RADIANT GROVE CHROME NG

F500394

BELROSE RADIANT EDWARDIAN BLACK NG

F500395

BELROSE RADIANT EDWARDIAN CHROME NG

F500396

BELROSE RADIANT SOHO CHROME NG

F500397

BELROSE RADIANT VICTORIAN BLACK NG

F500398

BELROSE RADIANT VICTORIAN CHROME NG

F500399

CASONA RADIANT COAL NG

F500400

CASONA RADIANT PEBBLE REMOTE NG

F500401

WALTHER CONVECTOR ELYSEE BRASS NG

F500402

WALTHER CONVECTOR GROVE BRASS NG

F500403

WALTHER CONVECTOR GROVE CHROME NG

F500404

MALLORY CONVECTOR EDWARDIAN CHROME NG

F500405

MALLORY CONVECTOR VICTORIAN CHROME NG

F500406

Superior Fires

Christchurch, Dorset BH23 2BT

Tel: 01202 588 632     
Fax: 01202 499326

www.superiorfires.co.uk

e : [email protected]

BELROSE RADIANT EDWARDIAN

MALLORY CONVECTOR VICTORIAN

CASONA RADIANT PEBBLE

WHATLEY RADIANT GROVE

MALLORY CONVECTOR EDWARDIAN

CASONA RADIANT COAL

WHATLEY RADIANT ELEGANCE

WALTHER CONVECTOR GROVE

BELROSE RADIANT VICTORIAN

WHATLEY RADIANT GROVE

WALTHER CONVECTOR ELYSEE

BELROSE RADIANT SOHO 

Summary of Contents for Belrose Radiant Edwardian F500395

Page 1: ... CHROME NG F500394 BELROSE RADIANT EDWARDIAN BLACK NG F500395 BELROSE RADIANT EDWARDIAN CHROME NG F500396 BELROSE RADIANT SOHO CHROME NG F500397 BELROSE RADIANT VICTORIAN BLACK NG F500398 BELROSE RADIANT VICTORIAN CHROME NG F500399 CASONA RADIANT COAL NG F500400 CASONA RADIANT PEBBLE REMOTE NG F500401 WALTHER CONVECTOR ELYSEE BRASS NG F500402 WALTHER CONVECTOR GROVE BRASS NG F500403 WALTHER CONVEC...

Page 2: ...battery approximately every twelve months Burner spark generator requirements 1 x PP3 type 9 volt Refer to the appropriate section of these instructions for details of how to change the battery Remote control models This appliance features a battery operated remote control system and under normal usage will need new batteries approximately every twelve months Remote control Handset requirements 1 ...

Page 3: ...any type of gas fire In some instances of this flue construction temperature cracking of the surface plaster may occur through no fault of the appliance An air gap or some form of insulation material should be installed to prevent normal flue temperatures from damaging wall surfaces Pre cast flues must be checked for mortar fangs and correct installation of joints flue sections in loft space and t...

Page 4: ...g providing the forward projection does not exceed 100mm Any com bustible side walls must be at least 500mm to the side of the radiant heat source As with all heating appliances any decorations soft furnishings and wall coverings i e flock blown vinyl and embossed paper positioned too close to the appliance may discolour or scorch Radiant models have a mounting depth of 180mm In accordance with BS...

Page 5: ...lled to allow plugs and screws to secure installation It is important that the sealing requirements of the appliance are met at all times and that the flue box is well sealed to any back or infill panel Note The DEPTH dimension is inclusive of any back or infill panel Stand the carton the right way up cut the strapping bands and remove the top endcap Read all the instructions before continuing to ...

Page 6: ...ews provided figure 4 The screws should locate into the pre punched holes in the sides of the firebox SUPPLY PIPE ENTRY All models Knockout holes are provided in the rear and sides of the firebox for use where concealed pipework is required Where necessary knock out the appropriate hole with a sharp tap from a hammer and fit the rubber grommet supplied A small incision can now be made in the rubbe...

Page 7: ...g When the opening is ready for installation of the fire the gas supply may be routed as per the examples shown in figure 9 IMPORTANT Wherever a concealed connection is made a rubber grommet must be used to seal the firebox The gas pipe must be suitably protected where it passes through fireplace openings Any sleeving should be sealed to the pipe at its ends This appliance is fitted with an inlet ...

Page 8: ... the inlet restrictor elbow from the inlet pipe Connect the previously installed gas supply to inlet restrictor elbow Place the burner unit into the firebox making sure that the rear lugs locate properly on to the ledge in the firebox Fit the two securing screws through the burner legs to secure the assembly Re fit the restrictor elbow to the inlet pipe of the appliance Please see the relevant sec...

Page 9: ...the control knob to an inter mediate position To turn the fire OFF move the slide control knob upwards fully to the position marked O The pilot is visible through the left hand side of the front ceramic strip When cold the coals or pebbles may be rotated for good viewing Turn the main burner con trol shown on left hand side of control valve knob fully anti clockwise Turn ignition knob shown on rig...

Page 10: ...f necessary reset by the gas supplier Upon satisfactory checking of the burner pressure turn the fire off disconnect the pressure gauge and refit the test point screw Light the fire and check for gas soundness In the event that the burner pressure is not in accordance with the figures stated in the data sec tion of these instructions the appliance must not be commissioned and the manufacturer shou...

Page 11: ...ly clean in the open air Be careful not to create dust from the coals Where necessary replace damaged components with genuine spares Seal scrap ceramic components in plastic bags and dispose at proper refuse sites as directed Re fit the ceramics by referring to the relevant section of these instructions 12 8 TESTING FOR SPILLAGE CONTINUED 11 2011 Focal Point Fires plc GB IE Match Crimp Tube Figure...

Page 12: ...t using two spanners to make cleaning easier Do not damage or try to remove the pilot injector The unit is factory set and the only check necessary is to ensure the spark gap is correct See specifications for gap setting Remove the burner unit as described previously Protect the hearth from potential damage Unroll the coiled tensioner cables from the rear of the firebox Remove the securing nip ple...

Page 13: ...Excessive flue pull Fire is too close the an air vent Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit there could be a problem with contamination of the gas supply drafts ventilation or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BENDTHETHERMOCOUPLETO MAKETHE P...

Page 14: ...f abnormal flue conditions occur It is NOT a sub stitute for an independently mounted Carbon Monoxide detector This fire is supplied with a particular style of firefront Use of the firefront will ensure an adequate airflow under the firebed for the cor rect functioning of this appliance Use ONLY the firefront supplied with the appliance Use of any other firefront could be dangerous Should any home...

Page 15: ...the control knob to an inter mediate position To turn the fire OFF move the slide control knob upwards upwards fully to the position marked O The pilot is visible through the left hand side of the front ceramic strip When cold the coals or pebbles may be rotated for good viewing Turn the main burner con trol shown on left hand side of control valve knob fully anti clockwise Turn ignition knob show...

Page 16: ... front coal strip should fit in front of the burner rail Again do not place on top of the burner rails When the front coal is in posi tion bend up the three metal tabs at the front of the tray to retain as shown in figure 8 3 Coals All of the coals are the same Take five coals and place them as shown in figure 9 Care should be taken to ensure that the coals bridge the gap between the front coal an...

Page 17: ...effect matrix used for pebble effect versions are of the same design as coal effect versions but have a different surface finish Position them as shown in figure 13 2 Open the bag of 16 ceramic pebbles All of these pebbles are the same size Take five pebbles and place them as shown in figure 14 Care should be taken to ensure that the pebbles bridge the gap between the front strip and the four supp...

Page 18: ... Refer back to section 6 0 Fuel bed layout coal effect option and fol low steps 1 and 2 The fuel effect matrix used for log effect versions is the same design as coal effect versions but has a different surface finish The front log strip is of a different design and must be handled with care Position them as shown in figure 18 2 Open the bag of 9 moulded ceramic logs All of the logs except two are...

Page 19: ... foreign matter is found on the fire it may indicate a need for servicing Do not use the fire until the source of the debris has been found and rectified Air vents where fitted should be checked periodically to ensure they are free from obstruction Before carrying out any of the following operations ensure that the fire is OFF and completely cold FIREFRONT Any dust accumulating in the firefront ma...

Page 20: ...30011 Injector stereo 76 manual control models F730091 Injector stereo 81 Remote control models F730046 Injector stereo 82 slide control models F730077 Burner assembly complete manual control TRAYEXCELC Burner assembly complete slide control TRAY087 Burner assembly complete remote control TRAY017 10 0 LIST OF REPLACEMENT PARTS GB IE 11 0 INSTALLATION DETAILS Name contact details of installer Suppl...

Reviews: