background image

(AC) Air-Cooled Chimney System*

 6” I.D. and 11” O.D. Air Cooled, Stainl. Steel inner and zinc coated steel exterior

* AC Chimney is NOT recommended at elevations above 4,000 feet or in cold climates 

(climates where temperatures will fall below 32° F / 0° C). 

Description

Cat./Part No.

One of the following adaptors is required 

if installing an AC chimney system

Starter Section (adaptor), 6”, AC, AC6SB

H3779

Starter 30º Elbow, 6” AC, AC6SB30

H3780

The following outside air kit is required if installing an AC chimney system

Chimney Outside Air Kit (flex, insulation, outside register 

and coupling), ACZI

H1967

Lengths and Misc. Chimney Components 

12” Length, 6” Dia. x 12” Long, AC6L12

H0472

18” Length, 6” Dia. x 12” Long, AC6L18

H0473

36” Length, 6” Dia. x 36” Long, AC6L36

H0474

48” Length, 6” Dia. x 48” Long, AC6L48

H0475

15º Elbow, 6” Dia., AC6E15

H0476

30º Elbow, 6” Dia., AC6E30

H0477

Rain Termination Cap, 6” Dia., AC6CPR

H0478

Spark Arrester Screen (universal spark arrester band), PE

PE

Wall Band, XBM

XBM

Supports

Offset Support, SO

SO

Support Section, AC6SL

H0481

Roof Support, ST

ST

Roof Brace, BS2

BS2

Roof Flashings

Flat Roof Flashing, ACF

H0494

1/12 - 7/12 (5º - 30º), AC Adj. Roof Flashing, FA

H0495

8/12 - 12/12 (30º - 45º), AC Adj. Roof Flashing, FB

H0496

Storm collar, ACFC

H0500

Misc.

Telescopic attic radiation shield, ACRST 

H0498

Firestop, ACBF 

H0485

Radiation Shield, ACRS 

H0486

Attic Radiation Shield, ACRSA 

H0487

Insulated Wall Radiation Shield, 30º, ACRSMI30 

H0489

Tubinox® LL Chimney  Lining System** 

Rigid Stainless Steel Liner For Relining A Masonry Chimney, 6” Diameter 

Listed to ULC-S635M, UL-1777 and ULC-S640M at 2100º F

Description

Cat./Part No.

6” Length, 6” Dia., 6LL6

6LL6

12” Length, 6” Dia., 6LL12

6LL12

24” Length, 6” Dia., 6LL24

6LL24

36” Length, 6” Dia., 6LL36

6LL36

48” Length, 6” Dia., 6LL48

6LL48

Adjustable Length (7” to 11”), 6” Dia., 6L7A

6L7A

Split Base Tee, 6” Dia., 6LT

6LT

Tee Cap, 6” Dia., 6TCS

6TCS

Twist Lock Tee Cap, 6” Dia., 6LTC

6LTC

Elbow 30º, 6” Dia., 6LE30

6LE30

Elbow 45º, 6” Dia., 6LE45

6LE45

Elbow 90º, 6” Dia., 6LE90

6LE90

Rain Termination Cap (regular), 6” Dia., 6LCS

6LCS

Rain Termination Cap (deluxe), 6” Dia., 6LCC

6LCC

Supports

Top Support, 6LST

6LST

Support Assembly, 6LSA

6LSA

Interior Support, 6LSB

6LSB

Adaptor Flexible Pipe (male), 6LAAM

6LAAM

Adaptor Flexible Pipe (female), 6LAAF

6LAAF

Stainless Steel Flex - five (5) feet Long, 6LLFLEX

6LLFLEX

Adjustable Insulated Wall Radiation Shield 6” - 12”, 6LRSMI

6LRSMI

Adaptors to Masonry Chimney

Masonry Chimney Adaptor, 45º, BISUMA 
(for use with Tubinox liner) CANADA ONLY

BISUMA

Masonry Chimney Adaptor, 30º, BISUMA30 
(for use with Tubinox liner)

BISUMA30

SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS

The components listed below must be ordered from Security Chimneys International™.  Contact your Security Chimneys Distributor or Dealer for ordering 

information.  

Security Chimneys International Limited
2125 Monterey, Laval, Quebec
Canada, H7L 3T6
securitychimneys.com

450-973-9999
1-800-361-4909 (USA)
1-800-667-3387 (Canada)

Gravity Kit Accessories

Elbow 90º, 8” dia., 7B26ZE90

7B26ZE90

Elbow 45º, 8” dia., 7B26ZE45

7B26ZE45

Telescopic length, 8” dia. (15” to 26”), 7B26ZLA

7B26ZLA

Adjustable length 8” dia (2” - 5”), 7B26ZL2A

7B26ZL2A

Wall radiation shield, 8” I.D., 7B26ZR

7B26ZR

Black grill with support, 7B30ZO

7B30ZO

Brass grill (for 7B30ZK), 7B30ZGB

7B30ZGB

Length one (1) feet, 8KL1

8KL1

Length two (2) feet, 8KL2

8KL2

Length three (3) feet, 8KL3

8KL3

Length four (4) feet, 8KL4

8KL4

Length five (5) feet, 8KL5

8KL5

**  

Alternate brand rigid stainless liner or stainless flex may be substituted but 

must be listed to UL-1777 for US application and ULC-S635 for existing 

masonry or ULC-S640M for new masonry applications in Canada. The steel 

rigid or flex liner must be rated at 2100º F (1100º C).

24

Summary of Contents for WCT6820

Page 1: ...of glass doors Install this fireplace in a square and plumb condition using shims as necessary at sides and or bottom Install the fireplace only as described in these instructions This installation ma...

Page 2: ...s ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free opera...

Page 3: ...del ASHT S 2100 HT6000 HT6103 or AC manufactured by Security Chimneys Inter national only including Chimney lengths Elbows where necessary Associated components as per these installation instructions...

Page 4: ...ing 10 to 20 minutes after reloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost can be closed and the primary air set to a medi...

Page 5: ...e Monitor Recommended Carbon Monoxide Poisoning Early signs of carbonmonoxidepoisoningaresimilartotheflu withheadaches dizzinessand ornausea Ifyou have these signs obtain fresh air immediately Somepeo...

Page 6: ...o 11 20 NOTE The use of a firewood moisture meter is rec ommended to ensure the firewood contains less than 20 moisture Seasoning Guide Softwoods 6 months to 18 months Hardwoods 12 months to 24 months...

Page 7: ...supplied will be necessary for this adjustment Checking Door Seal A one inch strip of paper may be used to perform a test of the integrity of the door seal Close the door on the paper in at least eigh...

Page 8: ...cover the entire width of the fireplace The combustible floor in front of the fireplace must be covered with a non combustible ma terial tile marble stone etc See Figure 7 Cold climate INSTALLATIONS...

Page 9: ...nstallation instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without notice Allframingdimensionscalculatedfor 1 2 dry wall at...

Page 10: ...tside Walls Of Chase Solid Continuous Surface Outside Base Insulation Thermal Barrier 8 Level 7 2 1 m Min 6 8 2 m Min 8 2 4 m Level 42 1067mm 2 x 3 Min 51mm x 76mm Rock Board or Other Noncombustible F...

Page 11: ...replace Blower The fireplace comes equipped with a heat acti vated blower It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electrical circui...

Page 12: ...diameter flexible pipe for the complete run up to thirty 30 feet and a 6 diameter pipe for a run of up to forty 40 feet The duct system must be installed respecting the following 1 Removetheplatesclo...

Page 13: ...11 When offsets are used the pipe may not penetrate a ceiling or floor unless it is running vertical no 30 offsets Outside Intake Screw Opening Facing Down Wall Aluminum Tape Plastic Cover Insulation...

Page 14: ...ofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using roofing nails 6 Place the spacers and the storm collar over the flashing and tighte...

Page 15: ...a plumb bob to line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below...

Page 16: ...22 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 243...

Page 17: ...bustible wall with the chimney at a 30 or 45 angle an angled firestop or wall radiation shield must be installed Only one is required NOTE 45 angle for Canada only RSMI45 In cold climate locations cli...

Page 18: ...are maintained at hot temperatures see Refueling For Best Performance To clean the glass there are a numberofspeciallydesignedcleaners YourIHP dealercanrecommendasuitablecleanerwhich is available in y...

Page 19: ...ns provided with the support CHIMNEY MODEL MAXIMUM HEIGHT OF SUPPORTED CHIMNEY Offset Support Roof Support ASHT HT6103 6 dia 28 feet 8 54 m 29 feet 8 84 m S 2100 HT6000 6 dia 18 feet 5 49 m 20 feet 6...

Page 20: ...cation Temporarily install the ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval d...

Page 21: ...bow 90 8 dia 7B26ZE90 H8948 Elbow 45 8 dia 7B26ZE45 H8949 Telescopic length 8 dia 15 to 26 7B26ZLA H8950 Adjustable length 8 dia 2 5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1...

Page 22: ...R2324 Log retainer bar PR SR2323 Door rod and lock PR SR2118 Steel door glass gasket PR SR1685D Cast iron door glass gasket PR SR1823H Steel and cast Iron door gasket PR SR1823G Touch up Paint Aerosol...

Page 23: ...ess Steel Chimney 6 I D and 8 O D Double Wall Stainl Steel Listed to CAN UCL S604 and UL 103HT Description Part Cat No Lengths and Misc Chimney Components 8 length 6 Dia 6L8 6L8 12 length 6 Dia 6L12 6...

Page 24: ...8 Length 6 Dia 6LL48 6LL48 Adjustable Length 7 to 11 6 Dia 6L7A 6L7A Split Base Tee 6 Dia 6LT 6LT Tee Cap 6 Dia 6TCS 6TCS Twist Lock Tee Cap 6 Dia 6LTC 6LTC Elbow 30 6 Dia 6LE30 6LE30 Elbow 45 6 Dia 6...

Page 25: ...ormal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning...

Page 26: ...ct your IHP dealer for any questions or concerns Replacement parts See Page 22 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered...

Reviews: