CHIMNEY SUPPORT INSTALLATION

Universal Roof Support

When installing a support, slightly lift the chimney system so the weight 

will lie on the support, not on the fireplace to reduce expansion noises. 

This support has three possible uses:

1. For ASHT+

*

 / 

*

 and S-2100+

*

 / 

*

, it must be used 

on a roof to support the chimney.

2. It may be used on a floor, ceiling or roof above an offset to support 

the chimney above the offset.

3. It may be used on a floor, ceiling or roof as a supplementary sup-

port. 

Table 6 

 gives maximum height of supported chimney.

NOTE:  For the AC chimney

*

, a support section must be used every forty 

(40) feet (12 m) instead of the universal roof support (ST

*

).

For roof support installation, refer to the instructions provided with the 

support.

UNIVERSAL OFFSET SUPPORT INSTALLATION

This support is used to support the chimney above an offset.  When 

the chimney offset is used to traverse a wall this support may be used 

on the wall to support the chimney.  The maximum heights are given in 

Table 6

.  For offset support installation, refer to the instructions provided 

with the support. 

CHIMNEY MODEL

*

MAXIMUM HEIGHT OF 

SUPPORTED CHIMNEY

Offset Support

Roof Support

ASHT+ /  (6” dia).

28 feet (8.54 m)

29 feet (8.84 m)

S-2100+ /  (6” dia).

18 feet (5.49 m)

20 feet (6.1 m)

AC  (6” dia).

40 feet (12.19 m)

50 feet (15.20 m)

Table  6

CHIMNEY CHASE AND MULTIPLE TERMINATIONS

For the purpose of this manual, a chimney chase is considered a part of 

the chimney system rather than part of a building.  The termination must 

be placed a minimum of 18” (460 mm) above the chase.

For installations where more than one chimney is located in the same 

chase or within the same area, we suggest that their terminations be 

separated by at least 16” (410 mm) horizontally, and 18” (460 mm) verti-

cally.  This separation is to prevent smoke migrating from one chimney 

to another (see 

Figure 31).

Figure 31

CHIMNEY ADAPTOR

*

 (S-2100+ / ) CANADA ONLY

The fireplace is normally supplied with a chimney adaptor suitable for the 

ASHT+

*

 / 

*

 chimney.  If you want to install a S-2100+

*

 / 

chimney, an adaptor is available (6UCA

*

(Figure 32)

.  A separate starter 

section will also be required if AC chimney is installed.

Figure 32

Chimney Adaptor 

*

 - 

Canada only

18” (460 mm)

16” (410 mm)

18” (460 mm)

18” (460 mm)

16” (410 mm)

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

19

*

Available from Security Chimneys™ 

Summary of Contents for WCT6820

Page 1: ...of glass doors Install this fireplace in a square and plumb condition using shims as necessary at sides and or bottom Install the fireplace only as described in these instructions This installation ma...

Page 2: ...s ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free opera...

Page 3: ...del ASHT S 2100 HT6000 HT6103 or AC manufactured by Security Chimneys Inter national only including Chimney lengths Elbows where necessary Associated components as per these installation instructions...

Page 4: ...ing 10 to 20 minutes after reloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost can be closed and the primary air set to a medi...

Page 5: ...e Monitor Recommended Carbon Monoxide Poisoning Early signs of carbonmonoxidepoisoningaresimilartotheflu withheadaches dizzinessand ornausea Ifyou have these signs obtain fresh air immediately Somepeo...

Page 6: ...o 11 20 NOTE The use of a firewood moisture meter is rec ommended to ensure the firewood contains less than 20 moisture Seasoning Guide Softwoods 6 months to 18 months Hardwoods 12 months to 24 months...

Page 7: ...supplied will be necessary for this adjustment Checking Door Seal A one inch strip of paper may be used to perform a test of the integrity of the door seal Close the door on the paper in at least eigh...

Page 8: ...cover the entire width of the fireplace The combustible floor in front of the fireplace must be covered with a non combustible ma terial tile marble stone etc See Figure 7 Cold climate INSTALLATIONS...

Page 9: ...nstallation instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without notice Allframingdimensionscalculatedfor 1 2 dry wall at...

Page 10: ...tside Walls Of Chase Solid Continuous Surface Outside Base Insulation Thermal Barrier 8 Level 7 2 1 m Min 6 8 2 m Min 8 2 4 m Level 42 1067mm 2 x 3 Min 51mm x 76mm Rock Board or Other Noncombustible F...

Page 11: ...replace Blower The fireplace comes equipped with a heat acti vated blower It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electrical circui...

Page 12: ...diameter flexible pipe for the complete run up to thirty 30 feet and a 6 diameter pipe for a run of up to forty 40 feet The duct system must be installed respecting the following 1 Removetheplatesclo...

Page 13: ...11 When offsets are used the pipe may not penetrate a ceiling or floor unless it is running vertical no 30 offsets Outside Intake Screw Opening Facing Down Wall Aluminum Tape Plastic Cover Insulation...

Page 14: ...ofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using roofing nails 6 Place the spacers and the storm collar over the flashing and tighte...

Page 15: ...a plumb bob to line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below...

Page 16: ...22 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 243...

Page 17: ...bustible wall with the chimney at a 30 or 45 angle an angled firestop or wall radiation shield must be installed Only one is required NOTE 45 angle for Canada only RSMI45 In cold climate locations cli...

Page 18: ...are maintained at hot temperatures see Refueling For Best Performance To clean the glass there are a numberofspeciallydesignedcleaners YourIHP dealercanrecommendasuitablecleanerwhich is available in y...

Page 19: ...ns provided with the support CHIMNEY MODEL MAXIMUM HEIGHT OF SUPPORTED CHIMNEY Offset Support Roof Support ASHT HT6103 6 dia 28 feet 8 54 m 29 feet 8 84 m S 2100 HT6000 6 dia 18 feet 5 49 m 20 feet 6...

Page 20: ...cation Temporarily install the ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval d...

Page 21: ...bow 90 8 dia 7B26ZE90 H8948 Elbow 45 8 dia 7B26ZE45 H8949 Telescopic length 8 dia 15 to 26 7B26ZLA H8950 Adjustable length 8 dia 2 5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1...

Page 22: ...R2324 Log retainer bar PR SR2323 Door rod and lock PR SR2118 Steel door glass gasket PR SR1685D Cast iron door glass gasket PR SR1823H Steel and cast Iron door gasket PR SR1823G Touch up Paint Aerosol...

Page 23: ...ess Steel Chimney 6 I D and 8 O D Double Wall Stainl Steel Listed to CAN UCL S604 and UL 103HT Description Part Cat No Lengths and Misc Chimney Components 8 length 6 Dia 6L8 6L8 12 length 6 Dia 6L12 6...

Page 24: ...8 Length 6 Dia 6LL48 6LL48 Adjustable Length 7 to 11 6 Dia 6L7A 6L7A Split Base Tee 6 Dia 6LT 6LT Tee Cap 6 Dia 6TCS 6TCS Twist Lock Tee Cap 6 Dia 6LTC 6LTC Elbow 30 6 Dia 6LE30 6LE30 Elbow 45 6 Dia 6...

Page 25: ...ormal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning...

Page 26: ...ct your IHP dealer for any questions or concerns Replacement parts See Page 22 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered...

Reviews: