NOTICE: State or local codes may only allow operation
of this appliance in a vented configuration. Check your
state or local codes.
WARNING: DO NOT INSTALL IN SLEEPING
ROOM OF MOBILE HOMES.
WARNING: A qualified service person must connect
fireplace to gas supply. Follow all local codes.
WARNING:Make sure the selector switch is in the
OFF position before installing appliance.
WARNING: Maintain the minimum clearances. If
you can, provide greater clearances from floor, ceiling
and adjoining wall.
WARNING: This appliance is equipped for either
natural gas or propane/LP gas but not both. Gas type
is indicated on the rating plate. Field conversion is
not permitted.
WARNING: Never install the appliance
• in a recreational vehicle
• where curtains, furniture, clothing or other flammable
objects are less than 36" from front, 42" from top of
appliance; for side clearances see
Figure 2, Page 6
• in high traffic areas
• in windy or drafty areas
CHECK GAS TYPE
Use the correct type of gas (natural or propane/LP)� If your gas supply
is not the correct gas type, do not install appliance� Call dealer where
you bought appliance for proper type appliance�
INSTALLATION AND CLEARANCES
* When you add the optional MAGNIFLAME EMBER BURNER KIT MFEB the
depth dimension increases by 3-1/2"
MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE
MATERIALS
Side Wall 16", Ceiling 42"
Floor 5", Front: 36"
LOG SIZING REQUIREMENTS
Log
Size
Minimum Firebox Size
Height Depth
Front
Width
Rear*
Width
LMF24GTA/B
LMF24MOA/B
29"
15�5"
32�5"
22�75"
LMF30GTA/B
LMF30MOA/B
29"
15�5"
39"
26�75"
LMF36GTA/B
LMF36MOA/B
29''
20''
47''
33''
OUTDOOR ENCLOSURE REQUIREMENTS
This appliance is considered to be installed outdoors if installed with
shelter no more inclusive than:
1� With walls on all sides, but with no overhead cover;
2� Within a partial enclosure which includes an overhead cover and no
more than two side walls� These side walls may be parallel, as in a
breezeway or at right angles to each side; or
3� Within a partial enclosure which includes an overhead cover and three
side walls; as long as 30% or more of the horizontal periphery of the
enclosure is permanently open�
This appliance must be installed in an approved fireplace� When
installed indoors or either indoors or outdoors with optional ember
burner MFEB, the appliance must be installed in a wood burning
fireplace with the flue damper in the open position� This appliance
may only be installed in a fireplace with no flue when installed in an
approved outdoor fireplace� When installed in an outdoor fireplace
with no flue, optional ember burner MFEB may not be used�
INSTALLATION