background image

SuperiorFireplaces.us.com

900464-01C

13

Installation 

Continued

Figure 18 - Installing Front Left Log

4�  Find the charred log (D-020)� See Figures 19, 19A, and 19B� The 

log has a slot in the bottom that fits over the square grate and 

rests against the burner tube as shown in Figure 19� Place this 

log on the base as shown in figures�

3�  Find the front left log (LMF24GTA/B or LMF24MOA/B models: D-059, 

LMF30GTA/B or  LMF30MOA/B models: D-017, LMF36GTA/B or 

LMF36MOA/B models: D-025)� See Figures 18, 18A, and 18B� The 

log has a rectangular stand off on the bottom that fits against the lip 

on the black metal base as shown in Figure 18A� The bottom of this 

log has a slot that fits over the second bar on the grate as shown in 

Figure 18B� Place the log on the base assembly as shown in figures�

Figure 18A - Installing Front Left Log Side View

Figure 18B - Installing Front Left Log

Charred Log

Log Notch

Right Front Log

Figure 19 - Installing Charred Log

Grate Finger

Log Slot

Front Left Log (D-059, 

D-017 or D-025)

Grate Fingers

Figure 19A - Installing Charred Log Top View

Figure 19B - Installing Charred Log Top Side View

 Square Grate

Log Notch

D020

Summary of Contents for MNF24ONE

Page 1: ...ce in an en closed space such as a camper tent car or home DANGER FIRE OR EXPLOSION HAZARD If you smell gas Shut off gas to the appliance Extinguish any open flame If odor continues leave the area immediately After leaving the area call your gas supplier or fire department Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or de...

Page 2: ...a qualified installer service agency or the gas supplier DANGER Carbon monoxide poisoning may lead to death WARNING This product can expose you to chemi calsincludingCarbonBlack whichisknowntotheState of California to cause cancer and Carbon Monoxide which is known to the State of California to cause birth defects or other reproductive harm For more information go to www P65Warnings ca gov WARNING...

Page 3: ...nstallanadjustablesafety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces 2 Do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors propane LP units only 3 If you smell gas shut off gas supply do not try to light any appliance do not touch any electrical switch do not use any phone in your buil...

Page 4: ...rorsimilarproducts turn appliance off If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls and furniture 9 Do not use this appliance as a wood burning appliance Use only the logs provided with the appliance Do not burn solid fuels in this appliance 10 Do not run appliance where flammable liquids or vapors are used or stored under dusty c...

Page 5: ... optional MAGNIFLAME EMBER BURNER KIT MFEB the depth dimension increases by 3 1 2 MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS Side Wall 16 Ceiling 42 Floor 5 Front 36 LOG SIZING REQUIREMENTS Log Size Minimum Firebox Size Height Depth Front Width Rear Width LMF24GTA B LMF24MOA B 29 15 5 32 5 22 75 LMF30GTA B LMF30MOA B 29 15 5 39 26 75 LMF36GTA B LMF36MOA B 29 20 47 33 OUTDOOR ENCLOSURE RE...

Page 6: ...t Noncombustible material must extend at least 8 up for all models If noncombustible material is less than 12 you must install the fireplace hood accessory See Figure 3 for minimum clearances If Using Mantel You must have noncombustible material s above the fireplace open ing Noncombustible materials such as slate marble tile etc must be at least 1 2 thick With sheet metal you must have noncombust...

Page 7: ...arances between fireplace opening and mantel shelf If you do not meet the clearances listed below you will need a hood Determining Minimum Mantel Clearance If you meet minimum clearance between mantel shelf and top of fireplace opening a hood is not required see Figure 4 Page 7 14 Min Combustible Material Noncombustible Material Figure 6 Minimum Fireplace Clearances If Installed at Floor Level Hea...

Page 8: ... Only Installation of this gas log set as a vented indoor appliance in the Commonwealth of Massachusetts requires the damper be permanently removed or welded in the fully open position You must install the damper clamp accessory to order see Acces sories Page 22 This will ensure vented operation see Figure 8 The damper clamp will keep damper open Installation instructions are included with clamp a...

Page 9: ...ead gas will void the manufacturer s warranty to this appliance Installation must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from appliance see Figure 12 Page 10 IMPORTANT Install equipment shutoff valve in an accessible location The equipment shutoff valve is for turning on or shutting off the gas to...

Page 10: ...ted on or near gas meter for natural gas or open propane LP supply tank valve 3 Make sure control knob of appliance is in the OFF position 4 Check all joints from gas meter to equipment shutoff valve for natural gas or propane LP supply to equipment shutoff valve for propane LP see Figure 14 or Figure 15 Page 11 Apply noncor rosive leak detection fluid to all joints Bubbles forming show a leak 5 C...

Page 11: ...F30ONE MNF30OPE LMF36GTA B LMF36MOA B WARNING Failure to position the parts in accor dance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury CAUTION Afterinstallationandperiodicallythere after check to ensure that no flame comes in contact with any log With appliance set to Hi check to see if flamescontactany...

Page 12: ... See Figures 17 17A and 17B Figure 17A shows how the log must fit against the end of the burner Figure 17B shows how the notch in log fits against the vertical portion of the burner tube Place this log on the base assembly by inserting it from the left side as shown in Figure 17 You will need to twist the log slightly to get it to fit against the burners properly It will rest even with the back ed...

Page 13: ...025 See Figures 18 18A and 18B The log has a rectangular stand off on the bottom that fits against the lip on the black metal base as shown in Figure 18A The bottom of this log has a slot that fits over the second bar on the grate as shown in Figure 18B Place the log on the base assembly as shown in figures Figure 18A Installing Front Left Log Side View Figure 18B Installing Front Left Log Charred...

Page 14: ...is on the top of the middle split log The right end of this log rests behind the knot on the top of the front right log 6 Find the right split crossover log D 022 The bottom of the log has a rectangular stand off that fits in the slots on the right side of the front right log and the middle split log Place this log as shown in Figure 21 Right Split Crossover Log D 022 Right Front Log Square Peg Fi...

Page 15: ...as supplier from a neighbor s phone Follow the gas supplier s instructions C Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety information first 2 Do not attempt to light the burne...

Page 16: ... The remote system is ready for use Pushing and holding the LEARN button for 6 seconds will result in clearing the transmitter security code from the module s memory The module will make three long beeps in succession when it has been cleared Remote Off Switch ADJ S Pilot Connection I Pilot Connection AF 4000 MOD Module Rt Side Figure 26 Gas Module Right Side AF 4000 MOD Module Lt Side AUX Connect...

Page 17: ...ing compressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the pilot assembly 1 Shut off unit Allow unit to cool for at least thirty minutes 2 Inspect burner and primary air inlet holes on injector holder for dust and dirt see Figure 31 3 Blow air through the ports slots and holes in the burner 4 Check injector holder located at e...

Page 18: ... Pilot I S AUX AF 5000MOD AF 4000 AF 4000B P Control Module Black Black Opti Red SWI SWI GND Black Red HI LO Main Black These wires are not used on this application CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous opera tion Verify proper operation after servicing ...

Page 19: ...n ON button on remote control is pressed there is spark at igniter but no ignition 1 Gas supply turned off or equipment shutoff valve closed 2 Air in gas lines when installed 3 Depleted gas supply propane LP only 4 Control module not in REMOTE position 5 Gas control valve pressure setting is not correct 6 Inlet gas pressure is too low 7 Burner orifice s clogged 8 Wire disconnected from gas control...

Page 20: ...and Main tenance Page 17 or replace burner orifice s White powder residue forming within burner box or on adjacent walls or furniture 1 When heated vapors from furniture polish wax carpet cleaners etc may turn into white powder residue 1 Turn appliance off when using furniture polish wax carpet cleaners or similar products Remote does not function 1 Battery is not installed Battery power is low 1 ...

Page 21: ...ature is too high 1 Check to see the minimum fireplace size requirements are met Page 6 Module makes one beep every one second 1 The burner did not successfully ignite 1 Press OFF then ON buttons to re attempt ignition Refer to When on button on remote control is pressed there is spark at igniter but no ignition on Page 19 Gas odor during combustion 1 Gas leak See Warning statement at top of Page ...

Page 22: ...uantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or application of this appliance please contact your dealer IHP 1769 East Lawrence Street Russellville AL 35654 Visit us at SuperiorFireplaces us com SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition appliance ...

Page 23: ...11 12 13 15 16 18 19 20 21 23 24 25 26 22 17 14 8 3 Cat No Model F2123 MNF24ONE F2125 MNF24OPE F2127 MNF30ONE F2129 MNF30OPE WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved with this heater may result in property damage or personal injury ...

Page 24: ... Tube x 3 8 NPT 1 17 J6532 Grate MF42 Stainless Steel 1 J8237 Grate MF48 Stainless Steel 1 18 J4711 Flextube Dormont 3 8 X 15 1 19 J4733 Brass Compression Cap Slv 3 8 1 20 J6127 Orifice Holder 90 Degree Elbow 1 21 J3604 Orifice 120 1 J3615 Orifice 070 1 22 J5198 Shutter Air 1 J5199 Shutter Air 1 23 J8173 Screw Blk Pan HD PH 10 24 X 3 4 2 24 J8172 Nut Hex 10 24 Blk Finish 2 25 J6548 Assembly Ignite...

Page 25: ... CAT NO Log Id CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J8245 D 061 J8253 D 019 J8259 D 027 Log Front Right 1 2 J8246 D 060 J8254 D 018 J8260 D 026 Log Back Left 1 3 J8247 D 059 J8255 D 017 J8261 D 025 Log Front Left 1 4 J6519 D 020 J6519 D 020 J6519 D 020 Log Charred 1 5 J8248 D 063 J8256 D 021 J8262 D 028 Log Middle Split 1 6 J8249 D 022 J8257 D 022 J8263 D 022 Log Right Split Crossover 1 7...

Page 26: ... 3 9 1 7 8 5 4 KEY NO CAT NO LOG ID NO CAT NO LOG ID NO CAT NO LOG ID NO DESCRIPTION QTY 1 J6696 D 061 J6516 D 019 J6527 D 027 Log Front Right 1 2 J6697 D 060 J6517 D 018 J6528 D 026 Log Back Left 1 3 J6698 D 059 J6518 D 017 J6529 D 025 Log Front Left 1 4 J6519 D 020 J6519 D 020 J6519 D 020 Log Charred 1 5 J6699 D 063 J6520 D 021 J6530 D 028 Log Middle Split 1 6 J6521 D 022 J6521 D 022 J6521 D 022...

Page 27: ...produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from faulty installation or application of the Product This Limited Three Year Warranty covers only parts and labor as provided herein In no case shall IHP be ...

Page 28: ...liance serial number Date appliance was Installed Type of gas appliance uses Dealer name Innovative Hearth Products IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1769 East Lawrence Street Russellville AL 35654 P900464 01 ...

Reviews: