126816-01F
17
SuperiorFireplaces.us.com
INSTALLATION
Continued
Figure 19- Disconnecting Switch from Control
Valve
Switch
Control
Valve
Figure 20 TF Series Burner System - Log
Compatibility Chart
LTF(18,24,30)-MM LOG PLACEMENT
It is very important to install the logs exactly as
instructed. Do not modify logs. Only use logs sup-
plied with appliance or as identifi ed for use with the
appliance as shown in
Figure 20, Page 17
. Each log
includes reference numbers formed in the bottom
or back of the log. The circled number indicates
the order it is placed on the burner system. The
remaining numbers indicate the size burner system
the logs are designed to fi t. For example, the fi rst
log for a 24 inch burner system will include a circled
1 and also a 24. The circled 1 indicates this is the
fi rst log to be installed. The 24 indicates this log
belongs to a 24 inch log set.
1. Place the rear log (#1) on base assembly as
shown in
Figure 21
. Log will fi t over right end
of burner and rest in middle of U-burner.
Figure 21 - Installing Log # 1
1
''U'' -
Burner
Base
assembly
2. Place the middle log (#2) in front of the U-
burner and against the edges of the plate as
shown in
Figure 22, Page 18
.
3. Place the front left log (#3) onto the base as-
sembly between the middle log
(#2) and the
grate fi ngers. The back of the front left log (#3)
will rest against the front of the middle log (#2).
The notch at the end of the front left log (#3)
will fi t around the grate bar. See
Figure 23,
Page 18
.
4. Place the front right log (#4) onto the base
assembly between the middle log (#2) and the
grate.
The back of the front right log (#4) will
rest against the front of the middle log (#2).
The notch in the end of the front right log (#4)
will fi t around the grate bar. See
Figure 24,
Page 18
.
TF Series Burner System - Log Compatibility
Chart
Burner Sys-
tem Models
Fiber Log
Models
Concrete Log
Models
TF18NR
TF18PR
LTF18MM
LTF18-RS
LTF18WT
TF2430NR
TF2430PR
LTF24MM
LTF30MM
LTF24-RS
LTF30-RS
LTF24WT
LTF30WT
WARNING: Failure to position
the parts in accordance with these
diagrams or failure to use only parts
specifi cally approved with this appli-
ance may result in property damage
or personal injury.
INSTALLING LOGS, EMBERS AND
VOLCANIC STONE
WARNING: After installation and periodi-
cally thereafter, check to ensure that no fl ame
comes in contact with any log. With the heater
set to High, check to see if fl ame contact any
log. If so, reposition logs according to the
log installation instructions in this manual.