25
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Installation Instructions
901140-00, 01/2021
Innovative Hearth Products
DRT63ST-B Power-Vent Direct-Vent Fireplaces
Remove Barrier (see Notice, Page 36)
This fireplace comes with a barrier to reduce the
likelihood of burns from touching hot glass. If
the barrier is damaged, the fireplace should be
turned off immediately and the fireplace must
not be operated until a new, approved factory
barrier for this unit is installed.
NOTE
: It will be nexcessary to remove the barrier
filler frim piece. Upon reinstall, insure that the
tabs on the barrier filler are engaged with the
slots in the base of the fireplace.
To remove barrier follow these steps.
1.Lift barrier up by the frame at the top.
2.Remove lower filler piece by pulling down
off of the barrier.
3.Lower barrier and push barrier to left to
release right side.
4.Pull the right side out of fireplace.
5.Remove barrier.
Glass Door Assembly
If not already done, remove the glass door
assembly on the control side of the fireplace
(see
Page 30
).
Step 5. REMOVE GLASS DOOR
ASSEMBLY (ON CONTROL SIDE)
WARNING
•
Handle this glass with extreme
care! Glass is susceptible to
damage – Do not scratch or
handle roughly while reinstall-
ing the glass door frame.
•
Do not attempt to substitute the
materials used on this door,
or replace cracked or broken
glass with any materials other
than those provided by the
appliance manufacturer.
•
The glass door of this appli-
ance must only be replaced
as a complete unit as provided
by the manufacturer. Do not
attempt to replace broken,
cracked or chipped glass
separately.
Figure 34 - Electronic Wiring Diagram
J-BOX/RECEPTIACLE
WIRING
120V, 60HZ, 1PH
Factory Wired
Field Wired
Junction Box
Tab Intact
Tab
Intact
n e
e r
G -
d n
u o r
G
e t i
h
W - l
a r t
u e
N 120 VAC - Black
Green
Ground
Screw
Whit
e
Gree
n
Neutral
Side of
Receptacle
Hot
Side of
Receptacle
Black
Figure 35 - Junction Box Wiring
Proflame
DFC Board
Pilot
Ground
Wire
Pilot
Tube
Electronic Pilot Assembly
ELECTRONIC WIRING DIAGRAM FOR POWER VENT FIREPLACES
Igniter Rod
Hood
Spark Wire Cable
Pilot Sensor Cable
Flame
Sensor
Proflame Valve
Electronic Modulation
Wall
Receiver
Cable Harness 102661-01
AC/DC
Power Adaptor
DFC Wire Harness 102662-01
Y
G
O
Y
G
O
W
W
THIS CONNECTOR
NOT USED ON POWER
VENT UNITS
PU
BL
G
PU
BL
G
W
B
BR
Y
O
B
BR
Y
O
Wiring Color Code
B = Black
BL = Blue
BR = Brown
G = Green
GY = Gray
O= Orange
PU = Purple
W = White
R = Red
Y = Yellow
Neutral
Hot
Ground
Junction Box
120V AC
G
B
W
Y
R
B
G
G
NOT USED
Exhaust Blower
(Field Installed)
Exhaust
Blower
Control
Module
B
Pressure
Switch
B
102663-01
W
W
Hi-Temp Sleeve
R
GY
Ground