Installation
900697-01 01/2017
Innovative Hearth Products
DRT4000 Series Direct-Vent Gas Fireplaces
38
NOTE:
The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit and
the other end of each conductor placed loose inside the bottom compartment.
CAUTION
In millivolt systems, do NOT connect a wall switch to a 120 V power supply.
Figure 30 - Wiring Diagram—SIT Electronic Gas Valves
WARNING
Electronic models of these appliances are equipped with a three-prong (grounding)
plug utilized in connecting the electronic components to the junction box in the lower
compartment. This grounding plug provides protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. DO NOT cut or remove the
grounding prong from the plug.
Electronic Wiring
One of the following optional controls must be used:
• Ecoflow Wireless Wall Switch (provided)
• Unit-Mounted ON/OFF Control
• Remote Control.
See the
Operation
section on
Page 49
for more details.
NOTE:
Electronic models must be connected to the main power supply.
1.
Route a 3-wire, 120 Vac, 60 Hz, 1 ph power supply to the fireplace junction box.
2.
Remove the electrical inlet cover plate from the side of the unit by removing the plate’s securing screws
(
Table 12
)
.
3.
If unit is not supplied with a strain relief, remove the cover plate knockout. Then, feed the power supply wire
through the knockout opening and into the unit junction box.
4.
Connect the black power supply wire to the lower outlet’s red pigtail lead
(
Figures 32-33
)
. Connect the white
power supply wire to the outlet’s common terminal.
5.
Connect the ground supply wire to the pigtail lead attached to the outlet’s green ground screw. Restrain the inlet
power lead per NEC or local codes.
6.
If a wall-mounted control switch is to be used, mount it in a convenient location on a wall near the fireplace.
7.
If an optional control is to be used, wire it in the low voltage circuit
(
Figures 30-31
)
.
NOTE:
The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit
and the other end of each conductor placed loose inside the bottom compartment.
8.
After the wiring is complete, replace the cover plate.