Installation
900948-00E, 07/2020
Innovative Hearth Products
DRT2000-C Series Direct-Vent Gas Fireplaces
20
4.
Determining Vent Setup in the Combination Venting Unit
(for 45” models only)
Combination venting units are shipped with round outer flue covers and inner flue cover plates installed that will require removal before connecting the vent pipe. If
you require a rear vented unit, remove the round outer rear flue cover
(2 screws,
Figure 9A
)
and the inner flue cover plate
(4 screws,
Figure 9B
).
If you require a top
vented unit, remove the round outer top flue cover
(2 screws,
Figure 9A
)
and the inner top flue cover plate
(2 screws,
Figure 9B
).
NOTE
: It may be necessary to remove the upper lintel and baffle to access the inner flue cover plates (3 screws).
Outer Top Flue Cover
Outer Rear
Flue Cover
Inner Top Flue
Cover Plate
Inner Rear Flue Cover Plate
Figure 9A
Figure 9B