Installation
900948-00C, 06/2019
Innovative Hearth Products
DRT2000-C Series Direct-Vent Gas Fireplaces
46
20.
Install the Finishing Materials
1.
Complete finished interior wall.
NOTE:
To install the fireplace facing flush with the finished
wall, position framework to accommodate the thickness of the
finished wall.
NOTE:
See
Cold Climate Insulation on
Page 11 and
Vent
Termination Clearances on
Page 13.
21.
Attach the Safety-in-Operation Warning Labels
1.
Attach the furnished safety instruction labels at all fireplace
operation and control points (Page 47).
NOTE:
The installer MUST ensure these warnings are properly
attached during installation. The warning labels are a critical
means of informing consumers of safe operation practices.
Figure 37 - Combustible Wall Framing
Top Of Appliance
3”
(77 mm)
This Area Must
Remain Clear
of Combustible
Materials
1” Min.
(26 mm)
4” Clearance Minimum
Hood
Standoff Provides Space
From Combustible Materials
Stand Off Must Be Bent
To Vertical Position
Combustible Finished
Wall Materials