14
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Power Vent Components
Locate the fireplace as instructed in this manual. Make the following modifications to add the com-
ponents used with the Power Vent Kit. This kit may only be used in conjunction with Direct-Vent
series electronic versions of Innovative Hearth Products Fireplaces. This installation must conform
with local codes, or, in the absence of local codes, with the (USA) National Fuel Gas Code, ANSI
Z223.1/NFPA 54 - latest edition, or (Canada) CAN/CGA-B149.1 - latest edition.
CAUTION: This power vent kit cannot be used with millivolt appliances. Use the kit only with
the electronically controlled fireplaces listed for its use as shown in this document.
Step 3. INSTALL THE VENT SYSTEM
General Information
These instructions should be used as a guide-
line and do not supersede local codes in any
way. Install venting according to local codes,
these instructions, and the (USA) National
Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest
edition, or (Canada) CAN/CGA-B149.1 - latest
edition.
These fireplaces are designed, tested and
listed for operation and installation only with
Secure Vent
®
(SV4.5) Direct-Vent System
Components, manufactured by IHP. These
approved vent system components are
labeled for identification. DO NOT use any
other manufacturer's vent components with
these appliances.
Ensure clearances are in accordance with
local installation codes and the requirements
of the gas supplier.
Dégagement conforme aux codes
d'installation locaux et aux exigences du
foumisseunde gaz.
Use only approved venting components. See
Approved Vent Components
on
Page 4
.
These fireplaces must be vented directly
to the outside.
The vent system may not service multiple
appliances, and must never be connected to a
flue serving a separate solid fuel burning ap-
pliance. The vent pipe is tested to be run inside
an enclosed wall (such as a chase). There is
no requirement for inspection openings in the
enclosing wall at any of the joints in the vent pipe.
Venting System
With the appliance secured in framing, de-
termine vent routing and identify the exterior
termination location. The following sections
describe horizontal (exterior wall) vent applica-
tions.
A list of approved venting components
is shown on
Page 30
.
2
1
3
4
6
5
7
8
Figure 11 - Power Vent Kit Components
8
9
Item No.
Part
Number
Description
Qty.
1
604187-01
Adaptor Assembly With Probe
1
2
601970-01
Vacuum Hose
1
3
601451-01
Termination Assembly
1
4
74L61
SV Termination Adaptor (SV4.5RCH)
1
5
102010-01
Strain Relief - 3/8"
1
6
H2246
Firestop Assembly (Horizontal)
1
7
102022-01
Hose Clamp - 11/32"
2
8
P-8-7102
Snap Bushing
1
9
-
Ring Terminal - #10
2
10
-
Insulated 1/4" Male Terminal
4
INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRC/DRT6340TYN AND DRC/DRT6345TYN) • INSTALLATION INSTRUCTIONS