 Brand Gas Log Set 

Limited Three Year Warranty

THE WARRANTY

Innovative Hearth Products Limited Three Year Warranty ("IHP") warrants your Superior

®

 brand Gas Log Set ("Product") to be free from defects in materials and workmanship 

at the time of manufacture. The logs and grate carry the Limited Three Year Warranty. After installation, if covered components manufactured by IHP are found to be defec-

tive in materials or workmanship during the Limited Three Year Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, 

repair or replace the covered components. If repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the 

IHP product, whichever is applicable. IHP will also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components. 

THERE ARE EXCLUSIONS AND LIMITATIONS to this Limited Three Year Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of 

product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This Limited Three Year Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be  purchased through a listed supplier of IHP and proof of purchase must be 

provided. The following do not carry the Limited Three Year Warranty but are warranted as follows:

Gas components

 – Repair or replacement for one year from the date of installation.

Remote control

 – Repair or replacement for one year from the date of installation.

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component.

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 

and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.

This Limited Three Year Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are 

not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this Limited Three Year Warranty. The duration of any implied warranty is limited to the duration of this expressed 

warranty.

No one is authorized to change this Limited Three Year Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and 

provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of 

this Limited Three Year Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this Limited Three Year Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this Limited Three Year Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. 

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining LHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

Summary of Contents for BGE18NR

Page 1: ...ions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual Installation and Operation Instructions Unvented Vent Fre...

Page 2: ...ual provided with this heater WARNING This appliance is for installationonlyinasolid fuelburn ing masonry or UL127 factory built fireplace or in a listed ventless fire box enclosure It is design certi...

Page 3: ...isheater Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the fireplace may not be working properly Get fr...

Page 4: ...not convertible for use with other gases glass doors shall be fully opened when the appliance is in operation If you operate heater with doors closed heat buildup inside fireplace will cause glass to...

Page 5: ...tterymarch Park Quincy MA 02169 7471 UNPACKING 1 Remove logs and appliance base assem bly from carton s COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS These appliances are approved for installation in the...

Page 6: ...following are excerpts from National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation All spaces in homes fall into one of the three following ventilation classifications WARNING...

Page 7: ...ngs add the volume of these rooms to the total volume of the space 2 Multiply the space volume by 20 to determine the maximum Btu Hr the space can support _________ volume of space x 20 Maxi mum Btu H...

Page 8: ...m Option 3 Ventilation Grills Into Adjoining Room Option 2 Ventilation Grills Into Adjoining Room Option 1 12 12 Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or du...

Page 9: ...any fresh air vents or ash clean out doors located on floor or wall of fire place If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper CAUTION...

Page 10: ...ling fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting NOTICE Manualcontrolheaters maybeusedasaventedproduct Ifso youmustalwaysrunheater with chimney fl...

Page 11: ...and Figure 7 Page 12 for minimum clearances IMPORTANT If you cannot meet these minimum clearances you must operate heater with chimney flue damper open Go to Installing Damper Clamp Accessory for Vent...

Page 12: ...ial For Massachusetts Residents Only Instal lation of this gas log set as a vented appliance in the Commonwealth of Massachusetts re quires the damper be permanently removed or welded in the fully ope...

Page 13: ...p so the minimum permanent flue open ing will be maintained at all times WARNING You must secure this heater to fireplace floor If not heater will move when you adjust controls Moving heater may cause...

Page 14: ...12 Attaching Base to Fireplace Floor Masonry Screw WARNING This appliance requires a 3 8 NPT National Pipe Thread inlet connection to the pressure regulator WARNING A qualified ser vicepersonmustconn...

Page 15: ...NATURAL From Gas Meter 5 W C to 10 5 W C Pressure CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 dia...

Page 16: ...after installing or servicing Correct all leaks at once WARNING Never use an open flame to check for a leak Applyanoncorrosiveleakdetec tion fluid to all joints Bubbles forming show a leak Correct all...

Page 17: ...see Figure 18 2 Install right bracket to right front of chassis using 2 screws provided see Figure 18 This bracket will also be used as remote control bracket if remote is installed Figure 18 Install...

Page 18: ...ll Front Log Bracket Bracket Figure 20 Installing Log Set Ramp Log Metal Tab 2 Rest rear log in back corner sections of base assembly as shown in Figure 21 Make sure log is completely vertical and not...

Page 19: ...e fiber ramp log can be identified by the shape and much lighter weight when compared to the other logs The log must sit flat on the black sheet metal and behind the left metal tab as shown Make sure...

Page 20: ...Right Ember Bed Log Right Ember Bed Log Hole Underneath Grate Prong 6 The left middle log 18 D 066 24 30 D 040 has a groove on the bottom to sit on the chassis and has to sit on the tab on the back o...

Page 21: ...rner out of position while installing this log 9 Rest the rear log 18 D 069 24 30 D 043 on the chassis behind the rear burner as shown in Figure 33 The bot tom of the rear log will sit into the rear l...

Page 22: ...rom ports as shown in Figure 39 3 Add volcanic stone and small decorative logs around base of heater if desired DO NOT place volcanic stone or additional logs on front burner or on logs Plac ing any m...

Page 23: ...Embers rockwool INSTALLATION Continued Ember Chunk 1 Ember Chunk 2 Ember Chunk 3 Flat Front Burner Figure 38 Platinum Bright Embers for BGE Series Figure 39 Placement of Glowing Embers for BGE Series...

Page 24: ...gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately ca...

Page 25: ...t step 6 Press in and turn control knob counter clockwise to the PILOT position Press in control knob for five 5 seconds see Figure 40 Page 24 NOTE You may be running this heater for the first time af...

Page 26: ...ame on ember burner with no yellow tipping Bright yellow rear burner flame flame will be blue next to the burner Dark orange rear burner flame Yellow or dark orange middle burner flame WARNING If inco...

Page 27: ...ay carry compressed air in a can If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could dam age the pilot assembly 1 Shut off unit...

Page 28: ...w if compressed air is not available CLEANING AND MAINTENANCE Continued Figure 47 Pilot Inlet Air Hole Your pilot may vary from pilot shown Pilot Air Inlet Hole Pilot Assembly LOGS If you remove logs...

Page 29: ...ilot but no ignition 1 Gas supply turned off or equipment shutoff valve closed 2 Control knob not in PILOT position 3 Control knob not pressed in while in PILOT position 4 Air in gas lines when in sta...

Page 30: ...mpany B Clean ODS pilot see Cleaning and Mainte nance Page 27 or re place ODS pilot assembly 6 Hand tighten until snug then tighten 1 4 turn more 7 Replace pilot assembly 8 Replace control valve One o...

Page 31: ...et warm up for a minute 2 Operate burners until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum instal lation clearances see Pages 9 through...

Page 32: ...s see Checking Gas Connections Page 16 2 Replace control valve or gas control Gas odor during combustion 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of pa...

Page 33: ...ease contact your IHP dealer for any questions or concerns When contacting your dealer please have your model and serial numbers of your appliance ready You can also visit our web site at SuperiorFire...

Page 34: ...F REMOTE AND RECEIVER WITH WHITE WALL PLATE Cat No F2236 Model RCKIT 4001 For all Remote Ready Models Allows the fireplace to be turned on and off by using a hand held remote control Purchase these ap...

Page 35: ...ned on and off with a wall switch LOG SCRAPS FLOOR MEDIA KIT 2 Cat No F0251 Model VTA LS5 2 LOG SCRAPS FLOOR MEDIA KIT 1 Cat No F0250 Model VTA LS5 1 DECORATIVE ASH BED CONTROL COVER KIT SIX PACK Cat...

Page 36: ...Inlet Gas Pressure in of water Max 10 5 W C Min 5 W C For purpose of input adjustment GLOW RAMP BURNERS Cat No Model Description F0040 BGE18NR 18 Millivolt Ramp Burner Embers Natural Gas F0044 BGE18P...

Page 37: ...ss 1 J3658 Warning Plate 1 J3846 Lighting Instruction Plate 1 J3664 Caution Decal 1 J3689 Hardware Kit 1 80L42 Volcanic Stone FDVS 1 J6504 Left Ember Chunk 1 1 J6505 Middle Ember Chunk 2 1 J6506 Right...

Page 38: ...Burner 1 J4819 Front Ramp Burner 1 15 J4923 Rear Ramp Burner 1 J4924 Rear Ramp Burner 1 16 J4842 Pilot Bracket 1 17 J4846 Heat Shield 1 18 J8174 Flex Tube 1 19 J5674 Air Shield 1 20 J3547 Captive Wash...

Page 39: ...05 J6554 J6554 Middle Right Log 1 4 J5706 J5712 J5718 Middle Left Log 1 5 J5704 J5716 J5716 Bottom Log Remote 1 6 J5709 J5715 J5721 Rear Log 1 7 J6747 J6747 J6747 Switch Log 1 PARTS LOG MODELS LBG18SM...

Page 40: ...Log 1 6 J5724 Back Log 1 7 J5725 Left Small Front Log 1 8 J5726 Right Small Front Log 1 9 J5727 Left Control Cover Log 1 10 J5728 Right Control Cover Log 1 11 J6747 Switch Log 1 1 2 3 4 5 6 7 8 9 10 1...

Page 41: ...J6643 D 058 J6653 D 039 Log Right Front 1 4 J6634 D 073 J6644 D 048 J6644 D 048 Log Left Front Ember Bed 1 5 J6635 D 072 J6645 D 047 J6645 D 047 Log Right Front Ember Bed 1 6 F2943 D 066 J6646 D 040...

Page 42: ..._______________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___________________...

Page 43: ...produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d d...

Page 44: ...tributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126829 01 Rev C 01 2019 1769 East Lawrence Street Russellville AL 35654 SuperiorFireplaces us com Record th...