background image

 

26

 

Available Coast-To-Coast and Internationally

 

 
 

Voltage Control Components 

POWERSTAT 

®

 

Variable Transformers 

VOLT-PAC 

®

 

Variable Transformers 

LUXTROL 

®

 

Lighting Controls 

5-WAY 

®

 

Binding Posts 

SUPERCON 

®

 

Electrical Connectors 

 

Power Quality Solutions 

STABILINE 

®

 

Automatic Voltage Regulators 

STABILINE 

®

 

Transient Voltage Surge 
Suppressors 

STABILINE 

®

 

Uninterruptible Power Supplies 

STABILINE 

®

 

Power Conditioners 

 
 
Voltage Control Components are available worldwide 
through an extensive Authorized Stocking Distributor 
network. These Distributors offer literature, technical 
assistance and a wide range of models off-the-shelf for 
fastest possible delivery and service. 
 
 
STABILINE Power Quality Solutions are available 
worldwide through an extensive Authorized Distributor 
and Reseller network, which offer literature, technical 
assistance and a select range of models off-the-shelf 
for fastest possible delivery and service. 
 
 

 
In addition, Superior Electric Manufacturer’s Representatives are available to provide prompt attention to customer 
needs. Call or fax for ordering and application information or for the address of the closest Manufacturer’s 
Representative, Authorized Distributor or Reseller. 
 
 
 

 

 
 
 
 

Telephone and Fax Numbers 
 
Telephone 

860-507-2025 

Fax: 

860-507-2050 

 
Customer Service: 

860-507-2025 Ext. 70782 

Product Application  860-507-2025 Ext. 72058 

Toll-Free (in U.S.A. and Canada only) 
 
Telephone 

1-800-787-3532 

Fax:  

1-800-821-1369 

 
Customer Service: 

1-800-787-3532 Ext. 70782 

Product Application:  1-800-787-3532 Ext. 70058 
 
 

 

1 Cowles Road • Plainville, CT 06062 

www.superiorelectric.com 

 
 

The right to make engineering refinements on all products is reserved.  Dimensions and other details are subject to change. 

©  24-Sep-2014 

213709-103E manual WHR32_T (20140924).docx 

 
 

An ISO9000 

Registered Company 

Summary of Contents for STABILINE WHR32 Series

Page 1: ...owing WHR62 T WHR92 T WHRS32 T WHRS62 T or WHRS92 T Superior Electric reserves the right to make engineering changes on all its products Such refinements may affect information given in the instructio...

Page 2: ...2...

Page 3: ...nd Shortage instructions packed with the unit outlines the procedure to follow if any parts are missing or damaged 2 0 DESCRIPTION 2 1 GENERAL WHR32 T Series STABILINE Automatic Voltage Regulators are...

Page 4: ...S Single Control D Double Control T Triple Control LNN Size Code 3 or 4 digits R Rack Cabinet T Tall Cabinet CB Input Circuit Breaker CS Input Circuit Breaker w 120vac Shunt Trip CR Input Circuit Brea...

Page 5: ...ange of knockouts are provided in the base and the rear panel of the unit for wire entry and exit The location of the power connections varies depending on the options provided On units with an input...

Page 6: ...SETTING OUTPUT VOLTAGE AND SENSITIVITY POTENTIOMETERS Normally the WHR Series voltage regulator should not be operated without the front panel s of the cabinet in place However during the initial oper...

Page 7: ...are wired to trip the input breaker The Shunt Trip Connections Diagram shows the typical connections 6 2 1 2 Under Voltage Trip L1 In unit where the model number designates the circuit breaker as CR...

Page 8: ...g without storing them in memory If the user changed the factory settings and did not select the store option the factory setting can be reinstated by pressing both RECALL buttons at the same time The...

Page 9: ...onnected for all boost the units will bring extra low voltages up to nominal but will not correct high input voltages Since operation in the all boost mode will increase the voltage and heating in the...

Page 10: ...ess the unit is overloaded there is little likelihood of component failure Warning Voltages are present inside this unit which can cause injury Therefore only personnel qualified to service electrical...

Page 11: ...e motor at the end of travel If the motor operates successfully in this test the problem may be with the control board 8 10 Inspect the POWERSTAT Variable Transformer brush s and commutator s for sign...

Page 12: ...50 2700 INPUT VOLTAGE 208Y 120 X 240Y 138 FREQUENCY 50 60 Hz X 60 Hz CONNECTION 3 Phase 4 Wire Wye RANGE 20 to 10 of Selected Output OUTPUT VOLTAGE 208Y 120 X 240Y 138 CONNECTION 3 Phase 3 or 4 Wire M...

Page 13: ...ilated enclosures intended for indoor use under usual service conditions Temperature Operating Average ambient temperature for any 24 hour period not to exceed 30 C 86 F and maximum temperature not to...

Page 14: ...1 227412 001 SM A1 F1 F2 F3 F4 FUSE 600V 104364 003 A1 LP1 LP2 LIGHT INDICATOR GREEN 227571 001 A1 M1 VOLTMETER 212917 004 A1 S1 SWITCH ROCKER SPST ON ON 227572 002 10 3 POWER COMPONENTS The following...

Page 15: ...r details The replacement brush assembly is listed along with its corresponding POWERSTAT Variable Transformer in the power component section 10 5 AUX POWER MODULE There are two standard power modules...

Page 16: ...16 11 0 SCHEMATIC For reference only use full size supplied with unit...

Page 17: ...17 12 0 FLOOR MOUNT DIMENSIONS Enclosures A through G Note All dimensions are inches millimeters...

Page 18: ...18 Enclosures A through G continues Note All dimensions are inches millimeters...

Page 19: ...19 Enclosures A through G continues Note All dimensions are inches millimeters...

Page 20: ...20 Enclosures DPLUS through GPLUS Note All dimensions are inches millimeters...

Page 21: ...21 Enclosures DPLUS through GPLUS continues Note All dimensions are inches millimeters...

Page 22: ...22 Enclosures DD through GG Note All dimensions are inches millimeters...

Page 23: ...23 Enclosures DD through GG continues Note All dimensions are inches millimeters...

Page 24: ...24 Enclosures EEE through GGG Note All dimensions are inches millimeters...

Page 25: ...25 Enclosures EEE through GGG continues Note All dimensions are inches millimeters...

Page 26: ...offer literature technical assistance and a select range of models off the shelf for fastest possible delivery and service In addition Superior Electric Manufacturer s Representatives are available t...

Reviews: