background image

5

Maintenance of the filter

•  Always disconnect from the mains supply before carrying out any maintenance!
•  Clean filter regularly, after first installation. If your pond is heavily polluted, the filter sponge 

should initially be cleaned daily. Remove the filter compartment cover (C-f) by simultaneously 
pressing the catch (C-g) on both sides and lifting the cover up.

•  Activated carbon absorbs color and toxins from the water and therefore becomes saturated. 

Replace the filter sponge and the filter media twice a season (more often if necessary), a Combi 
Clear Filter Media Set (art. 06020760) is available from your SuperFish dealer.

Maintenance of the pump and UVC-unit

•  Always disconnect from the mains supply before carrying out any maintenance!
•  Check monthly the operation of the UV lamp via the light indicator on the cover (C-d).
•  For maintenance of the pump and UVC, first loosen and remove the spray pipe (C-a). 

Press the catch (C-h) of the front cover on both sides and lift the cover up.

•  The pump and the UVC-unit are connected to each other by a 90° bend, loosen one of the swivels 

(D-a) to disconnect the pump from the UVC.

•  Your pump needs regular cleaning. There is no warranty on failures due to dirty pumps and scale 

build up inside the pump caused by improper maintenance.

•  Depending on usage the rotor of your pump can get worn out and damaged, this is normal, new 

rotors can be purchased at your dealer.

•  The UVC device should be cleaned twice a year. As soon as algae growth increases, check the UVC 

and UV-lamp and clean or exchange as needed.

•  The lamp is hot, wait 10 minutes after switch off before opening the unit.
•  Slide the red switch lock to unlock the unit head and housing (E-a).
•  Turn the unit head counter-clockwise against the stop then carefully pull it out of the housing (E-b).
•  Screw off the union nut, pull off the quartz glass including the O ring by a slight rotary movement (F). 

Clean the quartz glass outer face with SuperFish UVC Clean carefully and check for damage. 
Replace the UV-lamp if neccessairy (Recycling).

•  Insert the (replacement) UV lamp, then put into the light-shelter ring, flat seals and the UV Tube 

clip respectively (G).

•  Place the unit head with the fitted UV lamp and quartz glass into the housing (H). Turn it clockwise 

up to the stop and slide the red switch lock to the housing (J).

•  To avoid UVC overheating, switch off the UVC device when no water is flowing past it.
•  In the winter season, when the system is not used, the Combi Clear filter should be removed to 

avoid the risk of freezing.

• The UV-lamp should be replaced yearly.

Summary of Contents for Combi Clear

Page 1: ...ploi Gebruiksaanwijzing Combi Clear Filter The one plug solution for small ponds Die Ein Stecker L sung f r kleine Teiche La solution pr t l emploi pour les petits bassins De n stekker oplossing voor...

Page 2: ...2 C a b c d e f g h A B...

Page 3: ...3 D E F G J a b H b a a a...

Page 4: ...and return the unit to your dealer for repair or recycling Do not use this unit if any parts are damaged especially the quarts glass buy new parts at your dealer This appliance can be used by childre...

Page 5: ...n failures due to dirty pumps and scale build up inside the pump caused by improper maintenance Depending on usage the rotor of your pump can get worn out and damaged this is normal new rotors can be...

Page 6: ...icht mehr benutzen und zur Reparatur zur ck zu Ihrem H ndler bringen oder zur Entsorgung dem Recycling zuf hren Verwenden Sie dieses Ger t nicht wenn Teile besch digt sind vor allem das Quarzglas kauf...

Page 7: ...oder Kalkablagerungen in der Pumpe zur ckzuf hren sind Je nach Verwendung der Pumpe kann der Rotor in der Pumpe besch digt werden oder Verschlei zeigen Das ist normal Neue Rotoren erhalten Sie bei Ihr...

Page 8: ...er l appareil votre revendeur pour la r paration ou le recyclage Ne plus utiliser si des parties sont endommag es sp cifiquement le tube quartz contactez votre magasin pour les pi ces d tach es Cet ap...

Page 9: ...tre pompe n cessite un nettoyage r gulier Pas de garantie si la pompe est sale et pleine de calcaire dans et en dehors de la pompe et si elle est mal entretenue En cas de mauvaise utilisation de la po...

Page 10: ...Bij schade aan snoer of stekker dit apparaat niet meer te gebruiken maar bij uw dealer aanbieden ter reparatie of recycling Gebruik dit apparaat niet als er onderdelen beschadigd zijn in het bijzonde...

Page 11: ...te wijten aan vuil en kalkaanslag binnenin de pomp veroorzaakt door onjuist onderhoud valt niet onder de garantie Afhankelijk van het gebruik van de pomp kan de rotor van de pomp beschadigen of versli...

Page 12: ...st supply the entire unit with accessories in the event of a warranty claim We will inform you on receipt whether the unit will be repaired or replaced We accept no responsibility for damage as a resu...

Reviews: