background image

LED Parking Lot/Area Light

Important: Read all instructions prior to installation.

PLLD2 Series

4400 Earth City Expy, St. Louis, MO 63045          

866-590-3533            superbrightleds.com

Rev Date: V2.0 12/06/2019

5yr

User Manual

Dimensional Drawings (Accessories)

.70in

17.78mm

0.31in

8mm

 

5.49in

139.45mm

 

PLLD2-APM

0.31in

8mm

 

5.49in

139.45mm

 

PLLD2-FPM

.70in

17.78mm

PLLD2-SF 

PLLD2-WM

2.61in

66.29mm

.81in

20.57mm

 

.42in

10.67mm

 

 

.82in

20.83mm

 

 

2.90in

73.66mm

 

 

3.70in

93.98mm

 

Wiring Diagram

Line

Neutral

Ground

Black

L

L

N

N

GND

GND

White

Dim (+)

Dim (-)

Purple

+

+

-

-

Gray

Green

Line

Neutral

Ground

Black

L

L

N

N

GND

GND

White

Dim (+)

Dim (-)

Purple

+

+

-

-

Gray

Green

Note: External dimming is not applicable 
to 277–480 VAC models.

Summary of Contents for PLLD2 Series

Page 1: ... electrical codes To reduce the risk of electric shock ensure that the main power source and circuit breakers are switched off before performing any installation or wiring procedures Avoid looking directly into lamp when illuminated Ensure all mounts are securely attached and will support the weight of the fixture Failure to properly support fixture may result in damage or injury for which the man...

Page 2: ...ip fitter end together can be loosened to adjust the mounting angle of the light Retighten center bolt when the desired angle is achieved 1 Detach light flange bracket from trunnion mount 2 Run wiring through the flange that attaches to the light while sliding the flange into the light 3 Tighten the two bolts to secure flange to light 4 Use trunnion mount to make mounting holes on wall surface and...

Page 3: ... separate the flange end from the pole post mount end of the mount 2 Run wiring through the flange that attaches to the light while sliding the flange into the light 3 Tighten the two bolts to secure flange to light 4 Make appropriate mounting and wiring holes in pole post and attach mount end to pole post 5 Open lower access plate route wiring through to mount and attach flange end to mount 6 Wit...

Page 4: ...ories 70in 17 78mm 0 31in 8mm 5 49in 139 45mm PLLD2 APM 0 31in 8mm 5 49in 139 45mm PLLD2 FPM 70in 17 78mm PLLD2 SF PLLD2 WM 2 61in 66 29mm 81in 20 57mm 42in 10 67mm 82in 20 83mm 2 90in 73 66mm 3 70in 93 98mm Wiring Diagram Line Neutral Ground Black L L N N GND GND White Dim Dim Purple Gray Green Line Neutral Ground Black L L N N GND GND White Dim Dim Purple Gray Green Note External dimming is not ...

Reviews: