User Manual

Mounting Options

Lens Removal and Installation

Safety and Notes

Environmental Specifications

Operating Temperature

-40°–122° F(-40°–50° C)

IP Rating

IP65

Pole/Post Knuckle Mount (PLLD2-APM)

Slip-Fitter Knuckle Mount (PLLD2-SF)

Fixed Pole/Post Mount (PLLD2-FPM)

Trunnion Wall/Surface Mount (PLLD2-WM)

• 

Product should be installed and serviced by a certified electrician 

in accordance with applicable national, state, and local building 
and electrical codes.

•  To reduce the risk of electric shock, ensure that the main power 

source and circuit breakers are switched off before performing 

any installation or wiring procedures.

•  Avoid looking directly into lamp when illuminated.
•  Ensure all mounts are securely attached and will support the 

weight of the fixture. Failure to properly support fixture may 

result in damage or injury, for which the manufacturer does not 
assume responsibility.

Note: make certain to keep the light away from excess dust 
and moisture during this process.

1. Remove screws around perimeter of lens.
2. Gently pry lens from light.
3. Install new lens and securely tighten all screws.

Specifications

PLLD2-50K300-H3-HV (with PLLD2-SF)

Check product label for specific electrical 
specifications related to installation. 
Improper installation will void warranty.

Summary of Contents for PLLD2 Series

Page 1: ... electrical codes To reduce the risk of electric shock ensure that the main power source and circuit breakers are switched off before performing any installation or wiring procedures Avoid looking directly into lamp when illuminated Ensure all mounts are securely attached and will support the weight of the fixture Failure to properly support fixture may result in damage or injury for which the man...

Page 2: ...ip fitter end together can be loosened to adjust the mounting angle of the light Retighten center bolt when the desired angle is achieved 1 Detach light flange bracket from trunnion mount 2 Run wiring through the flange that attaches to the light while sliding the flange into the light 3 Tighten the two bolts to secure flange to light 4 Use trunnion mount to make mounting holes on wall surface and...

Page 3: ... separate the flange end from the pole post mount end of the mount 2 Run wiring through the flange that attaches to the light while sliding the flange into the light 3 Tighten the two bolts to secure flange to light 4 Make appropriate mounting and wiring holes in pole post and attach mount end to pole post 5 Open lower access plate route wiring through to mount and attach flange end to mount 6 Wit...

Page 4: ...ories 70in 17 78mm 0 31in 8mm 5 49in 139 45mm PLLD2 APM 0 31in 8mm 5 49in 139 45mm PLLD2 FPM 70in 17 78mm PLLD2 SF PLLD2 WM 2 61in 66 29mm 81in 20 57mm 42in 10 67mm 82in 20 83mm 2 90in 73 66mm 3 70in 93 98mm Wiring Diagram Line Neutral Ground Black L L N N GND GND White Dim Dim Purple Gray Green Line Neutral Ground Black L L N N GND GND White Dim Dim Purple Gray Green Note External dimming is not ...

Reviews: