background image

CLEANING PROCEDURE 

Supera Ice Machine Cleaning and Sanitizing Instructions 

It is the USER’S RESPONSIBILITY to see that the unit is properly maintained.  It is always 
preferable and less costly in the long run, to avoid possible down time by keeping it clean and 
adjusted as needed; and by replacing worn components before they can cause failure. The 
following is a list of recommended maintenance that will help keep the machine running with a 
minimum of problems. 

Maintenance and Cleaning should be scheduled at a minimum of twice per year. 

Note: Electrical power will be ON when performing the following cleaning instructions. 

1. Remove the ice machine front panel.
2. Make sure that all the ice is off of the evaporator. If ice is being made, wait for cycle

completion then turn the machine “OFF” at the ICE/OFF/WASH selector switch.

3. Remove or melt all ice in the storage bin.
4. Add recommended amount of approved nickel safe ice machine cleaner to the water

trough according to label instructions on the container.

5. Initiate the wash cycle at the ICE/OFF/WASH switch by placing the switch in the “WASH”

position. Allow the cleaner to circulate for approximately 15 minutes to remove mineral
deposits.

6. Depress the purge switch and hold until the ice machine cleaner has been flushed down the

drain and diluted by fresh incoming water.

7. Terminate the wash cycle at the ICE/OFF/WASH switch by placing the switch in the “OFF”

position. Remove the splash curtain and inspect the evaporator and water spillway to
ensure all mineral residue has been removed.

8. If necessary, wipe the evaporator, spillway and other water transport surfaces with a clean

soft cloth to remove any remaining residue. If necessary, remove the water distribution
tube, disassemble and clean with a bottlebrush. Reassemble all components and repeat
steps 4 through 7 as required to remove residue.

9. Turn OFF ice machine water supply and clean the water trough thoroughly to remove all

scale or slime build-up. If necessary, remove the water trough to reach all splash areas and
float.

10. Use an EPA approved food equipment sanitizer at the solution mix recommended by the

sanitizer manufacturer.

11. Add enough sanitizing solution to fill the water trough to overflowing and place the

ICE/OFF/WASH switch to the “WASH” position and allow circulation to occur for 10
minutes and inspect all disassembled fittings for leaks. During this time, wipe down all other
ice machine splash areas, plus the interior surfaces of the bin, deflector and door with the
remaining sanitizing solution. Inspect to insure that all functional parts, fasteners,
thermostat bulbs (if used), etc. are in the correct position.

12. Depress the purge switch and hold until sanitizer has been flushed down the drain. Turn ON

the ice machine water supply and continue to purge to the diluted sanitizing solution for
another 1 to 2 minutes.

13. Place the ICE/OFF/WASH switch to the “ICE” position and replace the front panel.
14. Discard the first two ice harvests. DO NOT USE any ice produced from the cleaning

solution.

© Supera    

September 2015           

       1

© Supera    

September 2015           

       1

3

Summary of Contents for UIM-240FA

Page 1: ...MANUAL This manual contains important information regarding your Supera unit Please read this manual thoroughly prior to equipment set up operation and maintenance Failure to comply with regular maint...

Page 2: ...one 866 953 3288 E mail Service SuperaCo com Any service communication must include Model Serial Number A detailed explanation of the issue Keep this manual for future reference The Supera Service Par...

Page 3: ...al evidence of loss or damage must be fully described and noted on your freight bill or express receipt and signed by the carrier s agent The claim should be filed on a form available from the carrier...

Page 4: ...vidually to a floor drain The use of condensate pumps for draining water is not recommended by Supera Supera assumes no responsibility for improperly installed equipment Note The purge drain fitting i...

Page 5: ...of an electrical fire Adjustments Level the machine within 1 8 inch in all directions Check the bin control for proper adjustment Check the water in the water trough for proper level Check the ice bri...

Page 6: ...tion All water supply lines must be installed per local codes Use 1 4 inch O D minimum on air cooled machines On water cooled machines 3 8 inch O D minimum tubing must be run to the condenser The wate...

Page 7: ...OFF WASH Switch is located in the control box Remove the grill screws to access the control box Note This unit does not have a splash curtain This model utilizes a thermostatic bin control in place o...

Page 8: ...This unit does not have a splash curtain This model utilizes a thermostatic bin control in place of a mechanical bin switch ON OFF WASH Switch is located in the control box Remove the grill screws to...

Page 9: ...now supplied to the water purge valve hot gas valve and the harvest motor The water purge valve opens and allows the water pump to purge the water remaining in the water trough removing impurities and...

Page 10: ...vaporators check the freeze pattern of the ice Ice should form evenly across the evaporator Bridge Thickness and Timer Adjustment Once the unit has gone through 1 or 2 harvest cycles verify that the i...

Page 11: ...e capillary tube thermo well the bin thermostat opens and the machine will shut off Bin Control Adjustment All Models Except Undercounter Models Check the bin switch for proper adjustment by swinging...

Page 12: ...the brass thermal well for 3 4 minutes It is imperative that enough ice be used for the 4 Slowly turn the adjustment screw counter clockwise until the machine shuts off If the screw is turned too qui...

Page 13: ...n 2 Check ice bridge thickness 3 Check water level in trough 4 Clean the condenser air cooled machines to insure unobstructed air flow 5 Check for leaks of any kind Water Refrigerant Oil Etc 6 Check t...

Page 14: ...move the splash curtain and inspect the evaporator and water spillway to ensure all mineral residue has been removed 8 If necessary wipe the evaporator spillway and other water transport surfaces with...

Page 15: ...urface of stainless steel that protects it from corrosion 3 Don t use cleaners that use chlorine or chlorides Don t use chlorine bleach or products like Comet to clean the steel Chlorides break down t...

Page 16: ...rvest or wait for cycle completion 3 Place the ICE OFF WASH switch to the OFF position The switch is located in the control box 4 Disconnect the tubing between the water pump discharge and water distr...

Page 17: ...Service History Model Number Serial Number Date Installed...

Page 18: ...d Under This Warranty SUPERA LLC s sole obligation under this warranty is limited to either repair or replacement of parts subject to the additional limitations below This warranty neither assumes nor...

Page 19: ...Supera Customer Care Toll Free Service Line 1 866 953 3288 For additional product and warranty information please visit our website at www SuperaCo com...

Reviews: