16
Load/Charger
Bistable Relay
Figure 5. Connect a bistable relay as an external disconnect device
4.5.2. Connecting a normal relay as an external disconnect device
1. When using a normal relay, connect it to Con 2 (I/O Connection 7), Pin 4 (Rc) and Pin 5 (Rnc)
as displayed in figure 6.
Normal relay
Load/Charger
Figure 6. Connect a normal relay as an external disconnect device.