During “Export Limit” setting and “Generation Limit” setting, the “Soft Export” mode and
“Hard Export” mode can be switched in “Sys CtrlMode”.
Please follow this flow chart to switch the “Soft Export” mode” and ”Hard Export”mode.
This settings are password protected. User should be able to view but not edit. If you are
installer, please contact importer for password. If there are any problems in the installation
process, please call Sunways service telephone at +86400-9922-958 or email Sunways at
[email protected] for password.
※ 6.9 Online Monitoring APP
Sunways inverter provides a monitoring port that can collect and transmit data from
the inverter to Sunways monitoring platform via an external monitoring device. Please
refer to the product nameplate on side of enclosure to get the monitoring application. If
download issues exist , contact your dealer or Sunways technical support.
6.8.2 Generation limit setting
Sunways inverter's Export Limit function can be enable if export limit is requried by local.
Please set “Generation Limit ” under the menu “Generation Limit” in “Advanced
Settings”. Please follow this flow chart to set”Generation Limit”:
The “Generation Limit” settings are password protected. User should be able to view but
not edit the Generation Limit. If you are installer, please contact importer for password.
If there are any problems in the installation process, please call Sunways service
telephone at +86400-9922-958 or email Sunways at [email protected] for
consultation.
Enable the Generation Limit function by short pressing or long pressing the
button on the inverter screen.
Set the percentage of the power that allowed to output , when set to XXX%,it means that
the maximum AC output power of inverter is XXX% of the inverter’s rated output power. If
you need Zero output , set the percentage to 0%.
6 General Operation
6 General Operation
Short press(1s), switch window
Long press(3s), enter the lower menu
Main
Window
How to view
General
Settings
Generation
Limit XXX%
Short press(1s), switch window
Long press(3s), enter the lower menu
Main
Window
How to setup
Advanced
Settings
Password
1111
Verified OK
Generation
Limit
Setting
Short press(1s), switch window
Long press(3s), enter the lower menu
Main
Window
How to setup
Advanced
Settings
Password
Verified OK
Export Limit
Feed in Grid
On/Off
Setting
Short press(1s), switch window
Long press(3s), enter the lower menu
Main
Window
Advanced
Settings
Password
Verified OK
Sys
CntlMode
Soft Export
Hard
Export
6..8.3 Soft export and hard export switch