42
43
※ 6.7 Power rate limit setting
Please set “Power rate limit ” under the menu “Power rate limit” in “Advanced Settings”.
Please follow this flow chart to set“Power rate limit”:
The “Power rate limit ” settings are password protected. User should be able to view
but not edit. If you are installer, please contact importer for password. If there are any
problems in the installation process, please call Sunways service telephone at +86400-
9922-958 or email Sunways at [email protected] for consultation.
Enable the Power rate limit function by short pressing or long pressing the button on the
inverter screen.
Set the percentage of the power that allowed to ramp up, when set to XXX%Pn/min, it
means that the maximum power allowed to ramp up is XXX%Pn/min of the inverter’s rated
output power.
※ 6.8 Export Limit and Generation Limit
6.8.1 Export limit fuction setting
Sunways inverter's Export Limit function can be enable if export limit is requried by local.
Please set “Export Limit” under the menu “Export Limit” in “Advanced Settings”.
Please follow this flow chart to set“Export Limit”:
The “Export Limit” settings are password protected. User should be able to view but
not edit the Export Limit. If you are installer, please contact importer for password. If
there are any problems in the installation process, please call Sunways service telephone
at +86400-9922-958 or email Sunways at [email protected] for consultation.
Enable the Export Limit function by short pressing or long pressing the button on
the inverter screen.
Set the percentage of the power that allowed to feed into grid, when set to XXX%,it
means that the maximum power allowed to feed into grid is XXX% of the inverter’s
rated output power. If you need Zero Export , set the percentage to 0%.
6 General Operation
6 General Operation
Short press(1s), switch window
Long press(3s), enter the lower menu
Main
Window
How to view
General
Settings
Power Rate Limit
XXX%Pn/min
Short press(1s), switch window
Long press(3s), enter the lower menu
Main
Window
How to setup
Advanced
Settings
Password
Verified OK
Power Rate
Limit
Setting
Short press(1s), switch window
Long press(3s), enter the lower menu
Main
Window
How to view
General
Settings
Generation
Limit XXX%