background image

 

Focus on customized architectural lighting                                   

 

wwww.suntechleds.com               [email protected] 

 

System connection

 

1

 The main controller is equipped with sub-controller and signal adaptor. The main control and sub-control 

working voltage is AC220V. The working voltage of the signal adaptor is the same as the working voltage of 
the pixel light. 

2

 Each sub-controller has 8 ports. The TTL sub-controller can carry 512 (RGB) pixels per port. The DMX 

sub-controller can  carry 170 (RGB) pixels per port. It is used with the signal adaptor and supports 200 
meters long distance transmission. 

3

 The main control and sub-control, sub-control and sub-control are connected by CAT5 twisted cables, the 

maximum distance of each section is less than 120 meters; the maximum transmission distance between 
the sub-controller and the signal adaptor is less than 120 meters. In this case, the maximum distance from 
the signal adaptor to the first pixel light is no more than 2 meters. 

4

 It is recommended that the maximum point spacing should not exceed 2.5 meters, and each intermediate 

power supply can support the power supply distance of 6 meters left and right (can be adjusted according to 
the project conditions). 
 

 

 
 
 

Control system 

TTL Dual channel real-time 

back up 

DMX512 

Main controller

 

 

 

Sub controller

 

MR-218A 

MR-218DW 

Signal adaptor 

 

 

Signal adaptor 

AD-001Differential 

  Signal adaptor 

AD-002Differential 

Signal adaptor 

Signal cable 

Two-core shielded wire 

Two-core shielded wire, 

Three-core shielded wire 

Summary of Contents for SPB018 Pixel light

Page 1: ...l and supports the installation of special shaped façade The product spacing and color can be customized it is suitable for large area display or lighting of building facades bridges and skylights Features A new generation of TTL serial technology design Standard DMX512 Control Protocol Industry leading wireless button type anti smash connection design High thermal conductivity glue full potting w...

Page 2: ...ight 6cd Beam angle Flat cover120 Ball cover 160 Electric grade Class III Other parameters Operating temperature 20 C to 50 C Storage temperature 40 C to 70 C Protection level IP66 Light distribution curve Model Light source quantities Light source Color Control DC Operating Voltage Power White light light intensity SPB018 01AU 01 1 PCS 3535 RGB W Dual channel Real time backup TTL 12V 0 3W 2 5cd S...

Page 3: ... wire and supports a single mounting piece to be fixed by wire The grid mounting piece is fixed by wire and supports profile mounting Commonly used wire accessories PC grid mount dimension drawing unit mm PC single mounting base size drawing unit mm PC strip mount dimension drawing unit mm Hanging hook Clip head Steel wire loop Hanging head 1 Hang head 3 Hanging head 2 ...

Page 4: ...agram after installation wire fixing and PC base installation Fix the two ends of the wire to the mounting base and then fix the PC mounting base to the wire The spacing is required according to the order spacing of the project order lights installation is completed Schematic diagram after installation is complete pixel light installation After the PC mounting base is firmly installed the point li...

Page 5: ...ight source is stuck into the strip shaped mounting member adjust the point spacing and flatness After the installation is completed the spacing of the strip mounts can be fine tuned to ensure that the installation is neat schematic diagram after installation Pixel light is installed The pixel light installation is completed and the system is connected installation point light source Take the ligh...

Page 6: ...ting profile cover The top cover of the profile with the point source is installed aligned with the mounting base and fastened to the profile mounting base installation carrier drilling Drill a hole in the position where the carrier is required to be drilled by selecting a suitable drill bit fixed frame mounting base After installing the frame base lock the mounting base with screws and do not loo...

Page 7: ...re connected by CAT5 twisted cables the maximum distance of each section is less than 120 meters the maximum transmission distance between the sub controller and the signal adaptor is less than 120 meters In this case the maximum distance from the signal adaptor to the first pixel light is no more than 2 meters 4 It is recommended that the maximum point spacing should not exceed 2 5 meters and eac...

Page 8: ...g an electric shock or amaging the lamp 4 When the external power cord is connected the corresponding measures of waterproofing and water leakage must be taken 5 The male and female waterproof protective covers for the products shall not be removed before the products are installed and connected 6 Quality Assurance Under normal conditions of use quality assurance is based on the proper storage ins...

Reviews: