Installation Requirements

The PicoCell must be installed in a shaded location, away from any source of heat and moisture, and in an area free of vegetation. 

Measures must also be made to protect the unit from damage by unauthorized persons, large animals, overgrowth, flooding, or other 

harm.

Warning

The PicoCell has voltages capable of causing severe injury or death by electrical shock. It should only be installed and serviced by 

Kasco Marine authorized dealers and installers. Integral solid-state short circuit protection does not provide branch circuit protection. 

Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes.

The PicoCell should be mounted at least 2 feet above the ground 

when possible. A minimum of 10 inches of clearance above the 

PicoCell is required for internal access. There must be no obstruc-

tion of air flow to the heatsink.

A typical installation on a solar 

panel structure

- Contact your Kasco Marine Dealer for any service or warranty 

claims.

- NEC codes take precedence over suggestions in this manual.

The controller should be installed and inspected by 

technically qualified personnel, and if the controller is not 

installed in compliance with national and local electrical codes and 

Kasco Marine recommendations, the controller can be damaged 

and fail to operate.

All electrical installations must be carried out in 

accordance with local standards and the National Electrical Code.

Conductor rated current, tempuratures, operating 

conditions and its power loss must be made in 

accordance with local standards and the National Electrical Code.

PicoCell

DC

Disconnect PV Solar Array

Kasco Motor

Unit

AC Source

Solar PV Panel

Solar PV Rack

Summary of Contents for Kasco PicoCell 3500

Page 1: ...ne Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 kascomarine com Owners Manual 1 Manual Number 884821 Rev 12 2020 PicoCell 3500 60 Hz PicoCell PicoBlender and SolSwitch are trademarks of SunTech...

Page 2: ...en dealing with any electrical and or moving equipment Under NO CIRCUMSTANCE should anyone enter the water with the electrical equipment plugged in and or in operation Warning Risk of Electrical Shock...

Page 3: ...ld be installed in the shade potentially mounted under the solar panels and away from the direct sun The PicoCell controller consists of several components as shown below The unit has five wire glands...

Page 4: ...r connecting all external wires to the PicoCell unit The smaller DIN rail on the lower left is used for an optional WiFi communication comm board which can be purchased upon request AC Source Input wi...

Page 5: ...sible A minimum of 10 inches of clearance above the PicoCell is required for internal access There must be no obstruc tion of air flow to the heatsink A typical installation on a solar panel structure...

Page 6: ...ing four screws not included through the 4 holes in the back bracket Step 2 Make sure all 4 set screws are used to hang the PicoCell onto the back bracket Step 3 Once the PicoCell is in place on the b...

Page 7: ...tches per the Kasco product that will be connected See DIP switch location settings on the next page 3 Power up the PicoCell from solar panels by switching the solar DC disconnect to the ON position A...

Page 8: ...phase pump does not start pumping water switch the positions of any two of the three motor wires It will change the direction of rotation and it should start pumping water PicoCell DIP Switch Setting...

Page 9: ...ower power level If the motor power continues to be outside the power range of the PicoCell it will shut off the motor operation If there is not enough solar power the unit s SOLAR LED light will blin...

Page 10: ...y continue operation without the thermal deration If the temperature of the PicoCell continues to increase it will eventually stop operating at which point the WARNING LED will be solid red 13 P a g e...