Overview

The Features of the PicoCell controller are shown below. The unit has five wire glands: two solar PV inputs, one motor output, and two 

glands for the external sensors.

Three LEDs are used to indicate the PicoCell controller’s operation. On the bottom left, next to the external sensors glands, there is a 

motor ON/OFF switch that controls the PicoCell’s operation of the motor.

Once the door of the enclosure is removed, there is access to the input terminal blocks (DIN rail mounts) on the right. Below the DIN 

rail is a grounding block for connecting the equipment ground. 

The installer should only use the DIN rail terminals for 

connecting all external wires to the PicoCell unit.

 The smaller DIN rail on the lower left is used for an optional WiFi 

communication (comm) board, which can be purchased upon request.

AC Source 

Input with 

12A Fuses

Solar PV

Input Terminal

Blocks

Float Switch and

Sensor Input

Terminal Blocks

Motor Output

Terminal Blocks

DIN Rail for

Placing Optional

Comm Board

External

Sensor Input

Motor Load

ON/OFF Switch

Motor Output

Ground Bar

AC Source and

Solar Input

Ground

Electric Lug

AC Source

ON/OFF

Switch

Solar PV Input

Terminal Block 2

Solar PV Input

Terminal Block 1

Float Switch and

Sensor Input

Terminal Blocks

Motor Output

Terminal Blocks

DIN Rail for Placing

Optional Comm

Board

External

Sensor Input

Motor Load

ON/OFF Switch

Motor Output

Motor Output

Motor and Both

Solar Inputs

Ground

Electrode Lug

Integrated DC

Disconnect

Summary of Contents for Kasco PicoCell 3500

Page 1: ...ne Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 kascomarine com Owners Manual 1 Manual Number 884821 Rev 12 2020 PicoCell 3500 60 Hz PicoCell PicoBlender and SolSwitch are trademarks of SunTech...

Page 2: ...en dealing with any electrical and or moving equipment Under NO CIRCUMSTANCE should anyone enter the water with the electrical equipment plugged in and or in operation Warning Risk of Electrical Shock...

Page 3: ...ld be installed in the shade potentially mounted under the solar panels and away from the direct sun The PicoCell controller consists of several components as shown below The unit has five wire glands...

Page 4: ...r connecting all external wires to the PicoCell unit The smaller DIN rail on the lower left is used for an optional WiFi communication comm board which can be purchased upon request AC Source Input wi...

Page 5: ...sible A minimum of 10 inches of clearance above the PicoCell is required for internal access There must be no obstruc tion of air flow to the heatsink A typical installation on a solar panel structure...

Page 6: ...ing four screws not included through the 4 holes in the back bracket Step 2 Make sure all 4 set screws are used to hang the PicoCell onto the back bracket Step 3 Once the PicoCell is in place on the b...

Page 7: ...tches per the Kasco product that will be connected See DIP switch location settings on the next page 3 Power up the PicoCell from solar panels by switching the solar DC disconnect to the ON position A...

Page 8: ...phase pump does not start pumping water switch the positions of any two of the three motor wires It will change the direction of rotation and it should start pumping water PicoCell DIP Switch Setting...

Page 9: ...ower power level If the motor power continues to be outside the power range of the PicoCell it will shut off the motor operation If there is not enough solar power the unit s SOLAR LED light will blin...

Page 10: ...y continue operation without the thermal deration If the temperature of the PicoCell continues to increase it will eventually stop operating at which point the WARNING LED will be solid red 13 P a g e...

Reviews: