SunTech Kasco PicoCell 3500 Owner'S Manual Download Page 2

Table of Contents

2

Important Safety

     pg. 2

PicoCell At-a-Glance

     pg. 3

PicoCell Overview

     pg. 4

Installation Requirements

     pg. 5

Mounting Instructions

     pg. 6

Wiring Instructions

     pg. 7-8

Operations

     pg. 9

Troubleshooting

     pg. 10

Important Safety:

Please read and follow these important instructions to help ensure your safety and the quality performance of your Kasco equipment.

This manual contains important instructions that should be followed during installation, operation, and maintenance of the PicoCell 

controller.

Carefully read and follow all safety instructions in this manual. Make sure that safety labels are always in good condition and replace 

any missing or damaged safety labels.

• 

Caution should be used when dealing with any electrical and/or moving equipment.

• 

Under NO CIRCUMSTANCE should anyone enter the water with the electrical equipment plugged in and/or in 

operation. 

Warning

Risk of Electrical Shock

Disconnect Power Before Removing Door Cover

Caution

Risk of Electrical Shock

Before performing any service or maintence inside the controller, or when connecting or disconnecting any wires, DISCONNECT the 

power and wait 90 seconds to allow the capacitor bank inside the controller to discharge to a level below 50Vdc.

Do Not:

 

- Turn on the power to the controller before terminating all wiring connections and closing the cover door.

 

- Connect power wiring to the controller before mounting the box.

 

- Service the device if your hands are wet or damp. Always make sure hands are dry before working on the controller.

 

- Modify inside the controller.

 

- Remove any parts of the controller unless instructed by this manual.

Summary of Contents for Kasco PicoCell 3500

Page 1: ...ne Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 kascomarine com Owners Manual 1 Manual Number 884821 Rev 12 2020 PicoCell 3500 60 Hz PicoCell PicoBlender and SolSwitch are trademarks of SunTech...

Page 2: ...en dealing with any electrical and or moving equipment Under NO CIRCUMSTANCE should anyone enter the water with the electrical equipment plugged in and or in operation Warning Risk of Electrical Shock...

Page 3: ...ld be installed in the shade potentially mounted under the solar panels and away from the direct sun The PicoCell controller consists of several components as shown below The unit has five wire glands...

Page 4: ...r connecting all external wires to the PicoCell unit The smaller DIN rail on the lower left is used for an optional WiFi communication comm board which can be purchased upon request AC Source Input wi...

Page 5: ...sible A minimum of 10 inches of clearance above the PicoCell is required for internal access There must be no obstruc tion of air flow to the heatsink A typical installation on a solar panel structure...

Page 6: ...ing four screws not included through the 4 holes in the back bracket Step 2 Make sure all 4 set screws are used to hang the PicoCell onto the back bracket Step 3 Once the PicoCell is in place on the b...

Page 7: ...tches per the Kasco product that will be connected See DIP switch location settings on the next page 3 Power up the PicoCell from solar panels by switching the solar DC disconnect to the ON position A...

Page 8: ...phase pump does not start pumping water switch the positions of any two of the three motor wires It will change the direction of rotation and it should start pumping water PicoCell DIP Switch Setting...

Page 9: ...ower power level If the motor power continues to be outside the power range of the PicoCell it will shut off the motor operation If there is not enough solar power the unit s SOLAR LED light will blin...

Page 10: ...y continue operation without the thermal deration If the temperature of the PicoCell continues to increase it will eventually stop operating at which point the WARNING LED will be solid red 13 P a g e...