14
Six clamps
mounting with
beams underneath
Test load:
positive 5400Pa
negative 3800Pa
Safety factor: 1.5
Clamping zone: A
0
= 1/4 short frame length ±50 mm
A
1
= 100 mm
16/T Series
20/W Series
24/V Series
60/W Series
72/V Series
A16/T Series
A60/W Series
B60/W Series
C54/U Series (30mm & 35mm)
C72/V Series
Six clamps
mounting with
beams underneath
Test load:
positive 5400Pa
negative 3800Pa
Safety factor: 1.5
Clamping zone: A
1
= 100 mm
A
2
= 200 mm
16/T Series
20/W Series
24/V Series
60/W Series
72/V Series
A16/T Series
A60/W Series
B60/W Series
A72/V Series
B72/V Series
C54/U Series (30mm & 35mm)
C72/V Series
Insertion
installation with
two clamps in the
middle
Test load:
positive 5400Pa
negative 3800Pa
Safety factor: 1.5
Clamping zone A = 100mm
16/T Series
20/W Series
24/V Series
A24/V Series
A60/W Series
B60/W Series
A72/V Series
B72/V Series
C72/V Series
* The module clamps must not come into contact with the front glass or deform the frame in any way. Avoid shading effects caused
by clamps or insertion systems. Drainage holes in the module frame must not be closed or obscured by the clamps;
** 35mm or 30mm represents the height of frame;
*** The mounting holes reserved for tracker mounting system with special accessories. If the length of module is over 2 meters, its
mechanical load value for tracker needs to be confirmed by module supplier
Electrical Installation
General Electrical Connection
Any hardware used must be compatible with any other used material to avoid galvanic corrosion. Defects caused
by corrosions void the warranty.
It is not recommended to use modules with different configurations (grounding, wiring) in the same system.