COOLING IN INDOOR OPERATION
The TRANSFORM unit stands in the room to be cooled.
Connect the air hose and the air outlet grid to the TRANSFORM unit as displayed in the illustration; the air
hose connection piece and air outlet grid need to be exchanged.
The warm extract air must be emitted from the room via the air hose. This can be executed e.g. via a tilted
window, a door or wall aperture. Make sure that no warm outside air can enter the room. For effective cooling,
we recommend our selection of various accessories which reduce or prevent entry of warm air into the room.
Set the function to „COOLING“. Set the target temperature using the temperature control. The settable
temperature range is between 17°C and 30°C target temperature. The TRANSFORM unit must only be used
in an ambient temperature of maximum 35°C.
COOLING IN OUTDOOR OPERATION
The unit is outside the room to be cooled.
Connect the air hose and the air outlet grid to the unit as displayed in the illustration; the air hose connection
piece and air outlet grid need to be exchanged.
Place the unit in the shade if possible and in a cool place in order to increase efficiency and to avoid
overheating. At an ambient temperature of over 35°C, the unit may deactivate. If this occurs continuously, we
recommend you temporarily use the INDOOR OPERATION of the unit. We recommend that a drainage hose
for condensation water be connected.
Set the function to „COOLING“. The settable temperature range is between 17°C and 30°C. This can be set
using the temperature control.
The air with high oxygen content cooled by the unit is led into the room via the air hose. This can be executed
e.g. via a tilted window, a door or wall aperture. Make sure that no warm outside air can enter the room. We
recommend that a drainage hose for condensation water be connected. For effective cooling, we recommend
our selection of various accessories which reduce or prevent entry of warm air into the room, or via the remote
control.
Using the „Comfort Control- S Kit“ (see segment accessories) you can also control the unit from inside using
the remote control.
Additional notes heating mode
✓
On cold days it is recommendable to start the unit early in order to get a warm room.
✓
For the heating function and to improve the heating effect and avoid lower temperatures (lower than 15°C)
we recommend you remove the rubber plug from the condensation water outlet and allow the condensation
water to leak out of the unit using the drainage hose. However, the drainage hose does not have to be
connected in the heating mode. Please make sure that the condensation water outlet is closed with the
rubber cap during operation. In such a case, proceed analogously to the emptying of the water tank in the
cooling function.
✓
The heating function of the unit must not be operated at a room temperature of more than 25°C or less
than 15°C. The unit can also be operated with heating function, if the outside temperature is lower than
15°C. However, you must then ensure that the unit is operated inside and the room temperature is at least
15°C.
HEATING IN INDOOR OPERATION
The unit is in the room to be heated.
Connect the air hose and the air outlet grid to the unit as displayed in the illustration; the air hose