TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL 

8 - EN 

 

10.

 

Maintenance 

Our collectors require the minimum maintenance and attendance such as summarized below. 

Every two years the following actions must be taken: 
 

I. Check that all the fastening screws of the supports and the screws of the collectors’ holders 
are well tightened. If not, fix them properly or change them if necessary. 
II. Clean the glass of the flat plate collectors from dust to increase efficiency. 
III. Check the level of the thermal fluid and fill the system if necessary using the upper point 
(venting point) of it or use any other convenient method. 
IV. Check for any leakage in the collectors and joints. 
V. Check again the slope of the collectors to avoid any formation of air traps. 

 

10.1.

 

Installation of collectors  PK SL AL  AS PART OF A FORCED CIRCULATION CENTRAL 

SOLAR SYSTEM 

 
Safety instructions: 

1. In case of using ladders, check them in order not to be damaged, and place them on 
secure surfaces in inclination ≈70°. For maximum protection use safety belts. 
2. We suggest the installer to wear protective gloves, safety shoes and helmet. Also 
protective glasses are necessary in some cases. 
3. In case that the place of installation is near electrical wires, keep safety distance 
(minimum 5 meters) and pay maximum attention when handing long parts of the support 
structures or tools for the installation. 
 

10.2.

 

Selection of installation area 

Check with the constructor of the building that the roof can withstand the load of the collectors 
full of water and ask for a written confirmation. Check the same with the local technical 
authorities if needed. 
Our collectors can be installed on flat roofs or on the ground or on sloped roofs with defined 
orientation and slope. 
For optimum performance, the collectors must face the south, for counties located in the 
Northern hemisphere and north for counties located in the Southern hemisphere. In case that it 
is not totally possible for the collectors to face the equator, you can turn it towards East up to 
30° if major hot water draw is before 2 p.m. or towards West u p to 30° if major hot water draw 
is after 2 pm. In both cases, the losses of the total annual solar contribution, is no more than 6%. 
To compensate energy losses there is the option to increase the number and surface of the 
collectors’ that are going to be installed. 
 
The following points must be considered when selecting the installation area: 
 
The position you will choose for the installation of the solar water heater, should not be shaded 
by any obstacles (trees, buildings, etc.) all around the year. 

Summary of Contents for PK SL AL 2.0

Page 1: ...TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL For SOLAR COLLECTORS SL AL With full plate aluminum absorber model serial number version 01 SRCC 2 2011...

Page 2: ...against lightning 6 6 COLLECTORS INTERCONNECTING IN A FIELD WITH 20m 6 7 Pressure loss 7 8 Recommended angle of installation of the collector 7 9 Collector protection against frost 8 10 Maintenance 8...

Page 3: ...measures to make them compliant regulations and norms concerning safety installation and operation of solar collectors protective gloves eyewear should be used make sure collector is securely attache...

Page 4: ...stallation user CAUTION Danger of injury damage of system due to incompetent operation The solar collector must be serviced only by persons familiar with the operation manual Structural changes to col...

Page 5: ...osiphonic solar systems or as part of forced circulation central system for heating sanitary water space heating air conditioning and pool heating The collectors PK SL AL are flat solar collectors wit...

Page 6: ...sting or earth them to an earth rod using wire of the same size The route of this wire should be always outdoors Ask specialist for more information 6 COLLECTORS INTERCONNECTING IN A FIELD WITH 20m Fo...

Page 7: ...lace plus 5 At this angle the maximum of the year around efficiency is achieved In case of difficulty to follow the above rule try to keep the inclination between 30 and 50 in order to benefit a minim...

Page 8: ...stallation is near electrical wires keep safety distance minimum 5 meters and pay maximum attention when handing long parts of the support structures or tools for the installation 10 2 Selection of in...

Page 9: ...eight of the collectors and other parts that will be installed The installation should be done according to the electric plumbing and town planning regulations applicable in the installation area 11 M...

Page 10: ...e between them must be kept at the minimum The system of collectors should be connected to the hot water tank heat exchanger of the tank with tubing properly insulated When installing collectors in pa...

Page 11: ...ticeable defects at the moment of purchase in which case the customer must make the claim at the shop immediately after noticing the defect as it is provided for in the general conditions of sale 14 2...

Page 12: ...ether the claim has grounds or not and whether the defect is within the scope of the warranty set forth in this certificate for limited warranty after which informs the customer as to its decision 14...

Page 13: ...aterial of solar glass K Heat tempered prismatic glass Material of pipes F Copper Absorber pipes pcs diameter G 9 x 8 11 x 8 Manifold pipes pcs diameter 2 x 22 Inlet Outlet P N 22 Material of absorber...

Page 14: ...l protection regulation 16 2 RECYCLING AND WASTE DISPOSAL At the end of life cycle of each product its components are due to be disposed of in conformity with regulatory prescriptions According to Dir...

Page 15: ...TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL 15 EN Notes...

Page 16: ...TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL 16 EN...

Reviews: