are intended, and therefore you must
first go through the choice of one of the
fuels.
The fuels are named:
Fuel1, Fuel2, Fuel3
and
Fuel4
. When there is a right arrow
after the selection line, you will move to
a new selection submenu:
10.3.1.
Fuel-independent
service
settings.
Equipment -
from this menu the pres
-
ence or absence of the optional burner
elements is set, as well as the polarity of
the action of the contacts of the room
thermostat or the forced stop circuit con
-
nected to the OD input.
Basic settings -
here you set the control
mode of the internal auger (burner au
-
ger), the maximum allowable heating
temperature of the boiler, the capacity of
the fuel auger and whether the cleaning
fan outlet (FC outlet) has an additional
wait if used to control a linear a drive
mechanism that has time to return to its
original state after moving forward.
Fire detection -
Adjusts the brightness
of the photo sensor to detect a lit or ex
-
tinguished fire and how long such light
should be measured to ensure recogni
-
tion.
Fire recognition
Fire
Flame
level
Duration
seconds
The fire will be considered lit if the pho
-
tosensor measures a level above 100 for
more than 20 seconds.
The fire will be considered extinguished
if the photosensor measures a level be
-
low 40 for more than 60 seconds.
Power modulation -
The temperature
differences between the set and mea
-
sured temperature of the boiler are
set, upon reaching which the power is
switched from one to another.
The operating conditions in power for
"Maintenance"
of the fire, waiting time
and maximum overheating of the tem
-
perature are also set.
Thermostat control -
here the way of
reducing the power of the burner is set,
when the room thermostat is activated
and the pumps are controlled in
"Heat-
ing priority"
mode. In this mode, once
the room thermostat has been acti
-
vated, if the burner has been operating
at power P3, for example, the time set
below will be maintained at this power
and then switched to power P2, P1 and
"Maintenance"
. The
"Maintenance"
power will last as long as it is set in the
"Service settings" menu -> "Power mod-
ulation"
line
"Time"
.
These settings are responsible for the
smooth reduction of the power supplied
to the heating system when the expected
room temperature is reached.
Output test -
all outputs of the control
-
ler can be controlled directly through
this menu. In order for this control to be
possible, the burner must be switched
off. There is a maximum activity time for
this menu without pressing buttons for 5
minutes. Then the outputs are turned off