verification of the above parameters.
Language -
Change the language.
Timers -
Setting and activating time inter
-
vals in which the operation of the burner
is allowed. If at least one of the three tim
-
ers is active, the burner will only run at
the intervals indicated by the active tim
-
ers! Outside the intervals, the burner will
be extinguished.
To see more clearly whether the
timers are activated and will
control the burner and what
their next on / off operation will
be and at what time, you can
display the information from
them in the information fields at
the top of the screen.
If there are active timers and
the burner is switched on, by
pressing and holding the "On
/ Off" button for more than 2
seconds, the timers will switch
off.
Fuel selection -
This menu selects the
preset fuel profile currently in use.
Info Fields —
Sets the information to
be displayed in the four information
fields at the top of the screen.
The possible labels and information dis
-
played in each field are the following:
•
Fire level
- level of illumination mea
-
sured by the photosensor
•
Chimney fan
- chimney fan speed
•
Timers
- next action controlled by tim
-
ers
•
Power
- calculated instantaneous pow
-
er obtained by burning pellets
•
DHW temp
- temperature of the hot
water boiler
•
Smoke rate
- exhaust gas temperature.
Pump control -
sets the operating mode
of the pumps of the external heating sys
-
tems, as well as their on and off tempera
-
tures. The pumps are as follows: a pump
for the heating system connected to the
PH outlet and a domestic hot water boil
-
er pump connected to the PWH outlet.
Manual refueling -
Manual switching on
of the fuel auger or circulation pumps.
This menu is useful for: filling the auger
when it is empty, switching on the auger
to measure the amount of pellets fed per
unit time in order to calibrate it, switch
-
ing on the circulation pumps for testing
or filling the installation with liquid.
New WiFi network -
If the NRC-6 has a
WiFi module for Internet connection
and if it is installed for the first time or
the WiFi network to which it is connect
-
ed needs to be changed, you must go
through this menu.
10.3. Installer (service) menu. Service
parameter settings.
These parameters are directly related to
the control of ignition, combustion and
safety when using the burner. Access to
them can be restricted with a code that
is set from the menu
"Service settings"
-> "Change code"
. To enter the service
settings, you must press and hold the
"Menu"
button for more than 2 seconds.
If an access code is activated, a screen for
entering it will be displayed first.
After entering the access code correctly,
a screen for selecting the service settings
menus will appear. Note that the NPBC-
V4C controller supports up to 4 different
profiles for different fuels.
Some of the settings do not depend on
the fuel used and are common to all fuels.
However, there are many parameters
that depend on the fuel for which they