![SunSynk SUNSYNK-3.6K-SG01LP1 User Manual Download Page 59](http://html1.mh-extra.com/html/sunsynk/sunsynk-3-6k-sg01lp1/sunsynk-3-6k-sg01lp1_user-manual_1400629059.webp)
HYBRID INVERTER | Installer Manual
59
5.23. Fault Codes
To check the fault codes click on the FAULT CODES icon on the settings menu.
If any of the fault messages listed in the following table appear on your inverter and the fault has not been
removed after re-starting, please contact your local vendor or service centre. The following information is
required:
1. Inverter serial number.
2. Distributor or service centre of the inverter.
3. On-grid Power Generation Date.
4. The problem description (including the fault code and indicator status displayed on the LCD) with as much
detail as possible.
5. Owner’s contact information.
Error Code
Description
Solutions
F13
Working Mode Change
Inverter work mode changed
1.Reset the inverter.
2.Seek help from Sunsynk.
F18
AC over current fault or
hardware
AC Slide over current fault.
1.Check if the backup load power is within the range of the
inverter.
2.Restart, and check if it is normal.
F20
DC over current fault of the
hardware
DC Over current fault
1.Check if PV module and battery connections.
2.Reset the system.
F23
AC leakage current is trans
over current
Leakage current fault
1.Check the PV module and inverter cables.
2.You may have a faulty PV panel (earth short)
3.Restart inverter