HYBRID INVERTER | Installer Manual
58
Aux Load off Battery % or Voltage
Battery level when the Aux load switches off
Aux Load on Battery % or Voltage
Battery level when the Aux load switches on.
Solar Power
Power limiter to the maximum power allowed to the Aux load.
Gen Input
Tick this box if using a Generator.
Aux Load Output
Tick this box if using an Aux or Smart Load.
For Micro inverter Input
Tick this box if intending to connect a supplementary inverter or
micro inverter (Max. 4kW).
Zero Export
Tick this box to stop exporting power produced by the Aux Load.
Gen Peak Shaving
Tick this box to use peak power shaving.
5.22. Advanced Settings for Peak Shaving
To configure Peak Power Shaving function, click on the AUX LOAD icon.
What this page displays:
Generator peak shaving is ON or OFF.
Peak Power Shaving value.
What you can do from this page:
Switch on the generator and/or grid peak
power saving and set the power shaving
value.
Peak Shaving:
This is a technique used to reduce electrical power consumption during periods of maximum
demand on the utility grid. This enables the user to save substantial amounts of money due to the expensive
peak power charges.