SunSun 51187 Operation Manual Download Page 4

The universal-hose stepped tails can be shortened according to the hose diameter if neces-
sary. 

Attach hoses and hose clamps.

Although the ultraviolet radiation is the lowest of the ionizing radiation, it can be dangerous for
people and other organisms as well. UV-radiation with longer wavelengths can destroy the
chemical bonds of the organic molecules, too. Therefore a responsible approach is necessary
when dealing with technical UV-sources.

Operate the tubes only if the housing is closed and not cracked.

 WARNING:

Read carefully all the safety guidelines and the instructions.

 Non-compliance with the safety rules

and regulations can lead to an electric shock, fire and/or serious injury. Keep the instructions and the
safety guidelines in a safe place in case you need them in the future.

Stability

The temperature of the conveyed liquid should not 35 

 in permanent operation.

The transport of flammable, gas forming or explosive fluids is forbidden. This pump cannot be used for
other fluids, especially not for motor fuels, cleaning agents or other chemical products.

Electrical connection

The electrical connection takes place via an electric safety socket 230 V ~ 50 Hz. Fuse protec-
tion at least 10 A.

The appliance is turned on/off by means of the ON/OFF switch. 

 Caution

The UVC filter should be placed in order to prevent the water from reaching it. The distance
between the pond edge and the filter should be at least 2 m. The UV lamp cannot be operated
under water.

The power supply of the UVC filter must not be turned on before the water circulation has
been started.

Position the UVC filter on a safe and stable place because the pond filter light tube is made of
quartz glass that can easily break.

Do not turn the power on before all device components have been installed.

If the quartz glass tube or the upper part of the UVC filter is damaged, the pond pressure filter
cannot be used.

The UVC filter cannot be used either if there are people in the pond water.

Make sure that the used voltage and the frequency correspond to those indicated on the filter
label.

After having installed the device, you must pay attention to the national and international in-
stallation rules.

Please do not pull on the connecting cord. Keep it away from heat, grease and sharp objects.

Make sure that the upper part of the filter is exposed to a pressure lower than 0.3 bar.

When there is frost, remove the UV filter.

When you install the UV filter, do not expose it to direct sunlight.

Dirt   influences   the   efficiency   of   the   quartz   glass   tube;   therefore   it   needs   to   be   regularly
cleaned.

To secure the proper functioning of the device, the UV-quartz tube should be replaced after
8000 operating hours.

If the upper part is blocked by sand, the quartz tube can be destroyed. Please place the filter
sponge in the inlet of the water pump.

Ultraviolet light is harmful for the eyes and skin. Do not look directly into the ultraviolet light
and do not expose your skin to it.

© by WilTec Wildanger Technik GmbH 

Item 51187

Page 4 

http://www.WilTec.de
http://www.aoyue.eu

 

04 2021

-1

http://www.teichtip.de

Summary of Contents for 51187

Page 1: ...rating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignif...

Page 2: ...nguages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our...

Page 3: ...le for the safety of the working environment If the cable or the plug is damaged due to external influences the cable must not be repaired It has to be replaced with a new one This work can be carried...

Page 4: ...V lamp cannot be operated under water The power supply of the UVC filter must not be turned on before the water circulation has been started Position the UVC filter on a safe and stable place because...

Page 5: ...is in operation when the mains power plug is plugged in Technical data Model CPF 50000 Power consumption W 55 Power supply 230 V 50 Hz Flow rate max h 13000 Hose connection 20 38 1 Max pond size with...

Page 6: ...yers of filter sponges arranged from coarse to fine 2 The second stage is biological By means of so called bio balls depending on the model the accumulation of bio organisms is stimulated These microo...

Page 7: ...nection is damaged Never use the UVC filter if there are people in the water The installed temperature sensor inside the UVC filter switches off the UVC lamp automatic ally in case of an overheating A...

Page 8: ...ting the cleaning connection In order to mount a drain hose permanently on a cleaning connection screw off the closing cap from the cleaning connection mount the third hose nozzle along with an approp...

Page 9: ...the filter sponges before the water flows towards the filter inside E Cleaning of the pond water When flowing out the water is exposed to the ultraviolet radiation of the UVC lamp thus des troying ge...

Page 10: ...ing conditions the filter must be removed Never expose the filter to direct sunlight After the filter has been installed in the right place and the pump has been connected the UVC unit can be switched...

Page 11: ...llation example with pump filter system flower bed watering and a small water course by WilTec Wildanger Technik GmbH Item 51187 Page 11 http www WilTec de http www aoyue eu 04 2021 1 http www teichti...

Page 12: ...f the flow is too low and it cannot be improved by the cleaning function the sponges have to be washed or replaced Please do not use chemical cleaning agents for not to kill the microorganisms of the...

Page 13: ...ean and wet cloth 7 Check if everything is in order If anything is broken replace it 8 Set up all part of the filter as before and start up the filter again The wearing parts filter mats tubes quartz...

Page 14: ...50 5 O ring 2 21 13 Clamp 22 Rubber gasket 6 Quartz glass tube 14 O ring 3 421 7 5 23 Rest 7 Sealing screw 15 1 Inner container 24 Shaft connection 8 Lid 15 2 Container 25 Handle 9 1 Sponge blue 15 3...

Page 15: ...ts out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the corr...

Reviews: