If you install the device or repair it, switch off the lamp and pump power supply.
The device must be installed on a horizontal flat surface with the feet downwards. For safety
reasons it not allowed to install the device otherwise.
Application/operation mode
This UVC device ensures for healthy fish and clear water. The water is transported by a pump through
the UVC device. There, passing a UV lamp, it is submitted to a UVC radiation by the means of which
the bacteria, pathogens and floating algae are destroyed, and thus the water is cleaned.
To achieve an optimum result, the device should operate during 24 hours a day in the frost-free sea -
son.
Commissioning
Turn on the pump and wait until the device is filled with water.
Check all connections regarding their tightness.
The device is in operation when the mains power plug is plugged in.
Technical data
Model
CPF-50000
Power consumption
(W)
55
Power supply
230 V / 50 Hz
Flow rate max.
(
ℓ
⁄
h
)
13000
Hose connection
(
㎜
)
20–38 (¾”–1½”)
Max. pond size
(ℓ)
with fish
40000
without fish
80000
Dimensions
(
㎜
)
600 × 600 × 815
Safety
This device produces a harmful radiation. The direct contact with skin or eyes is harmful and
must be avoided.
The device must not be operated when it is damaged.
The device has to be turned off when no water is transported.
In case of frost, the device has to be demounted. Store it in a frost-protected area.
Before operating the device, make sure that all hoses and connections are properly connec-
ted. The UVC clarifier only has to be used for water!
The integrated UV lamp may be switched on as soon as the filter system has been placed in
an appropriate location and the pump has been properly connected.
© by WilTec Wildanger Technik GmbH
Item 51187