23
77
Voltage Specifications & Change
1) Voltage specifications
2) Check voltage display LED
A. SPS/HT-5050B1, 50100B1
Usable frequency : 50 / 60 Hz
Single-phase
AC 240V
AC 220V
AC 200V
Three-phase
AC 240V
AC 220V
AC 200V
Phase
Input Voltage (V)
A. The LED display lamp on the front of the AMP box changes according to the input voltage.
[ Fig. 18 ]
Input Voltage (V)
[Error
±
5V]
LED color
RED
[ HIGH ]
YELLOW
[ HIGH ]
GREEN
[ GOOD ]
YELLOW
[ LOW ]
RED
[ LOW ]
Over AC 270
AC270 ~ AC243
AC243 ~ AC193
AC193 ~ AC160
Below AC160
Voltage status
overvoltage
Circuit breaker turns off the power.
overvoltage
Normal voltage
low-voltage
low-voltage
Circuit breaker turns off the
power of the control box.
▶
Input Voltage: this indicates the secondary voltage of
the transformer in the AMP box and output voltage
through the transformer when the user inputs the AC
200 ~ 240V.
Do not use under the different voltage conditions. This causes the equipment damage.
Caution
When the AMP box powers on, the voltage display LED color should be green.
If the LED color is red or yellow, the input power is not consistent with the specifications. Please
contact our repair center engineer.
Caution