5.11.2) Y Origin Setting
1) Disassemble the bed cover(right).
2) Set the distance between the Y-feed arm and the bed side at 24mm.
3) Move the upper feed plate to the center in the Y-axis direction and make sure to maintain the distance at 24mm.
4) Loosen the tightening screw for the Y-sensor plate. Move the end of the Y-sensor plate to the center of the sensor and
fasten the tightening screw with a spanner.
Tightening
Screw
Sensor
Y-Sensor Plate