13
3.2) Machine Installation
3.2.1) Installation Environment
1) To prevent accidents stemming from mal-operation, do not use the machine if the voltage is 10% above the rated
voltage.
2) To prevent accidents stemming from mal-operation, make sure to check if the air pressure is proper before using any
air pressure devices such as air cylinder.
3) Proper temperature during machine operation : 0
°
~ 40
°
C (32
°
~ 104
°
F)
4) Proper temperature during machine storage :
-
25
°
~ 55
°
C (
-
13
°
~ 131
°
F)
5) Humidity : Relative humidity – within 45 ~ 85%
3.2.2) Electricity Environment
1) Power voltage
-
The power voltage shall be within 10% of the rated voltage.
-
It is recommended to use the power frequency /- 1% of the rated frequency (50/60Hz).
2) Noise of electromagnetic wave
-
Do not share the power with the products which have either strong magnetic field or use high frequency. Make the
machine stay away from the products mentioned above.
3) Take care not to spill water and coffee on the machine.
4) Do not drop Control Box and the motor to the floor.
3.2.3) Table Installation
1) Table fixing
-
Insert the shock absorbing rubber into the level adjuster and raise it until the caster freely moves.
-
After the table is installed, tighten the nut to fix the level adjuster.
2) Table height adjustment
-
Use the bolts attached to the table to adjust the height of the table to make sure that the users can smoothly and
conveniently work.
Nut
Level Adjuster
Shock Absorbing
Rubber
Caster
Bolt
To guarantee smooth operation of the product, the installation environment shall be prepared as
described in User’s Manual. Otherwise, unexpected damage might occur to the product.
Caution
The voltage shall be within 10% of the rated voltage.
Warning