Form #43219030
Sept 2012
a) Lower the heater to the floor or other suitable working surface.
b) Remove the reflector from the reflector mounting panels or collar.
c) Disconnect the electrode cable and flame sensor cable, or pilot burner tubing.
d) Remove the reflector mounting panels from the heater body
e) Remove the emitter face from the heater body. This surface unit is attached by ¼” Hex Head
machine screws (10 on the SGM3, 16 on the SGM6, and 26 on the SGM10) Use caution in this
operation as the emitter surface is fragile.
f) Carefully brush any foreign material from the back side of the emitter face and the inside of the
heater.
g) The insulation gasket which was between the heater body and the emitter face must be replaced
when the heater is reassembled. Order two (2) of each of the part numbers indicated for your
particular model:
SGM3: #40446080 and #40446130
SGM6: #40446080 and #40446090
SGM10: #40446080 and #40446110.
15) REPLACING PARTS
Ensure that at all times when parts are being
replaced, both gas and electrical supplies are
disconnected. Various parts are available from the
factory for replacement by a licensed person.
Refer to the Replacement Parts Guide in Section
17 for all replacement parts.
16) INSTALLATION DATA
Date of
Installation:
Number of
Heaters in System:
Heater Serial Number:
Heater Model:
SGM
—
N=Natural Gas
L=Propane Gas
13
Summary of Contents for SGM10
Page 18: ...Form 43219030 Sept 2012 17 ...